Council archive · source document
Approved Plans MCU17-0009 & OPW17-0037 · MCU17/0009
Plans and drawings: the text below has words only, no drawings.
Very large file (10.4 MB): may take a few minutes to open.
- NOOSA COUNCIL APPROVED PLAN MCU17/0009 & OPW17/0037 12 JUN 2017 [OCR of page images] LEGEND PROPOSED FLOOR AREAS unit 2 (noth) - floor areas PROPOSED GROSS FLOOR AREAS (GFA) REAL PROPERTY DESCRIPTION Cope Trew unit 1 (south) - floor areas : “oo a LOT: 8 on SP179879 ner | REFIGERATOR anne & DOORS internal -level g - = 852m? internal - level g - garage = 87.4m level 1 - gross floor areas (gfa) areas PARISH: Weyba HP | HOT PLATES ENING Pat internal | level g - garage = 85.2m level 1 = 79.3m2 y! sur | SHOWER (0-DOUBLE) X__ | OPENING PANEL -level 1 = 74.7m? “ever = om -unit 4 (south) - 64.98m? (excl. lift shaft & stair no.2) COUNTY: March sue. | SINGLE LAUNDRY TUB 08s | OBSCURE GLASS - level 2 = 79.3m? ; ; AREA = 543 m? FG | FIXED GLASS - level 2 = 74.7? . . -unit 2 (north) - 66.19m? (excl. stair no.2) = 040 Mm WM | WASHINE MACHINE i (total internal = 246.0m?) 2 MH CEILING MANHOLE SG | SAFETY GLASS (total internal = 234.6m2) sternal k vel 1 bedrm 4 deck = 8 6m? total level 4 - 134.17m PLANNING AREA ZONING DP 100mm PVC DOWNPIPE DH | DOUBLE HUNG eee | | fel bo deck = 7b meee ede adr 172 SEMI-DETACHED HOUSINGZONE | Senn | BY Blahons bs level 2 front deck (under roof) = 16,6m? (otal extemal = 25 8m? . level 2 - gross floor areas (gfa) areas LOCAL AUTHORITY HW | INSTANTANEOUS HOT WATER system | TL | TIMBERLOUVRES (total external = 244m?) " -unit 1 (south) - 55.38m? (excl. lift shaft & stair no.2) NOOSA SHIRE COUNCIL Se WASTE RAINAGE PIT WINDOW NUMBER . > -unit 2 (north) - 57.28m? (excl. stair no.2) EX.FAN | EXHAUST FAN TOTAL INTERNAL FLOOR AREA (unit 4 + 2) = 480.6m 2 PROPOSED USE RWH | RAIN WATER HEAD (29) poor NuMBER . total level 2 - 112.66 mae nDeEy FAG | FASCIAGUTTER- HALF ROUND PROFILE | LL / TOTAL EXTI RNAL FLOOR AREA (under roof - unit 1 + 2) = 50.2m? CLASS 1 DUPLEX HC HOSE COCK . 9 _ 2 Cc CONTROL JOINT site co erage = 175.20m? (32.27%) (allowed 217.2m? - 40%) TOTAL GROSS FLOOR AREA - 243.83m? (allowable (0.45 x Site) = 244.35m?) HR HAND RAIL WC(vrh) | WALL CLADDING - (vertical / horizontal) AS SELECTED landscaped drea = 204.1m? (37.6%) (min.req'd - 192m?) WC(fc) | WALL CLADDING - FIBRE CEMENT MRS | METAL ROOF SHEETING So > PRWS | POLYCARBONATE ROOF / WALL SHEETING 2, TS TIMBER SCREENING (hwd dressed) & Sx, eS TP- TIMBER POSTS / COLUMNS TO ENG'S REQ'TS - TYPE B B SHS STEEL COLUMN TO ENG'S REQ'TS - (e - exposed, aluminium cover plates to suit) gm a a TSID | TIMBER STAIRS / DECK (hwd dressed) 33 pe S TRB(exp)|_ TIMBER RAFTERS / BATTENS EXPOSED (hwd dressed) 85 ra a SH SUN HOOD (as detailed) & g 90mm INTERNAL STUD WALL AS SPEC za ;—— Fefer to External Works Plan & Details for more 2 BLOCK WALL (THICK. AS NOM) information on driveway / fence | ) 3050, 1940 6990 , 3000p szth setback font elevation GRATED SUMP 42.01 7 7t 7t 7 Proposed driveway crossover in accordance op GRATED DRAIN | * 43.19 yd3.48 |7_, _ stepped conc. block retaining wall - | with IPWEA Std Dwg R-0050 & Council req'ts 3 = max.2.0m high - refer to external works plan —» Sars aaah MB Comma | ELECTRICAL METER BOX & SWITCHBOARD 4167, a J : 33.711m_52°55'20" “& details for futher information \*°* oO | xt 18.68 GHW ===] | GAS HOT WATER UNIT x Tito [12.48% \ 1 t garden + 2 8 Z i ET ee tL eR 8 __ tems rBack. =] ols =] | SD SD Be | | = SY SCHEDULE OF DA DRAWINGS Bs 3 g concrete ey ses 2.0m SETBACK e a. S faa ess DAO1 SITE PLAN & NOTES 1:200 ol SH [= 42.38% 3.14 line of roof over (level 2) | aire 2 | = = A DA02a_EXIST.CONTOUR + GROUND LEVEL PLAN 1:100 ~~ | a I 4p, fo Ibe _| ie = > DAQ2b PROPOSED GROUND LEVEL PLAN 1:100 7 | | | wom unit 2 | P\ | eq “+ DAO3 PROPOSED LEVEL 1 PLAN 1:100 ‘Hn level G - FFL 12.300 RTH = line of entry roof bver = DA04 PROPOSED LEVEL 2 PLAN 1:100 3 | So level 1 - FFL 15.050 | | | OO EN g | DA0S PROPOSED ROOF PLAN 4:10 8 \ - We Le gs DA06 ELEVATIONS - NORTHEAST 1:100 So | | y ox, level 2 - FFL 47.800 | | o 3 12m. high rendered conc block SS - \ PLUNGE ben DAQ7 ELEVATIONS - SOUTH-EAST 1:100 3 | fire rated partition wall FRL 60/60/60 | 2 garde —tt fég ty 600mm plcoat & Bones | E- _| 14 only POOL ‘Eb avericatbootfencing to detal Ww DA08 ELEVATIONS - SOUTH-WEST & NORTH-WEST _1:100 4 404 g| driveway! S) ot sot Ap t 9 [3] | | 'e | & foul saltwater | 187 4.8m max. high pooat vertical DAO SECTION A-A- TYPICAL 1:00 ax Lo =| 5 [2 lg gan || pool fencing to deta | DA10 EXTERNAL WORKS PLAN 1:100 “| JB et) 1a sl 18 ; : ie nN 8 aS | | 8 | lg unl t { level G - FFL 12.300 had Ig | a | | | PLUNGE = toe nsdn p0) s BD | 6 |2 10 level 1 - FFL 15.050 J; 8} i is | } ROO! cS vertical pool fencing to detail m DA-DO1 DRIVEWAY PLAN 1100 fi fl jay | [oreo TAAL AE | 2 =a S m DA-D02 DRIVEWAY SECTION 1100 ae) 4 Y l 2 5 ‘ : SL P| Lo — i | Ls pinecenyeotores 2.0m SETBACK DA-LO1 LANDSCAPE PLAN 1:100 Sle STE fo | CF TTT : X/8 nl — tying court (unit 4) 3S —t tb 15m SETBACK —+ DA-H01 DRAINAGE & STORMWATER PLAN 1:100 | a dp 43,05 & a A4A2 ~ [15.4 6 proposed new conc.footpath in accordance ™ saan —= ith IPWEA Std Dwg R-0065 & Council req's | f = 3950 L 3930 —33.711m 82 55'20' 5050 wi 9 ouncil req! existing timber 7 cop, fence to remain 6680" L 4140 L ; 7X 1887 gm 7I 7 fence as detailed 184 ge ‘— 190mm reinforced conc. ‘~ part timber fence to be 190mm reinforced conc. . " 00 eS block wall to garage side © removed/ replaced where —_ block retaining wall to L psig timber at wall to ground level only needed tore ing drying court fence to remain 000), boundary Court hound 9, _mey NOOSA COUNCIL /01\, PROPOSED SITE PLAN APPROVED PLAN \/ 120683 MCU17/0009 & OPW17/0037 o 4 5m nb: existing contours & levels NB: Refer to Landscape Plan / External 12 JUN 2017 [Ltt 1 | | shown with proposed levels Works Plan / Driveway Plan for more detail to driveway / external areas | / | F DA ISSUE - DRIVEWAY AMEND 03.04.2017 I Issue Amendment Date The design & drawings shown on these | |Q COX G ina pr ice desi gn #8] PROJECT DRAWING TITLE SCALE DWE No. ISSUE Pans ae oyna ee architectural building designer|= NEW DUPLEX FOR D & L ARMSTRONG SITE PLAN 1200 @ AS DA 01 F property of 'georgina price design’. No é DATE = unauthorised copies shall be made. WmiG GesEginapE Tce destonacon-st, 00422444096 3 23 GRANT STREET, NOOSA HEADS, Q 4567 OCTOBER 2016 creating environmentally sensitive spaces| 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans MCU17-0009 & OPW17-0037.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.