‘5 x 50 shear block fixed
90 x 45 shear block fixed to top plate
with 3/75 mm, No 14 type 17 screws
Bo!
D
tom chord
clearance for
truss deflection
Bracing wall
TRUSS TO BRACING WALL 10kn. per set
WALL AT RIGHT ANGLES TO TRUSS
PLYBRACE AS 1684.2-2006 Minimum plywood Bracing
TABLE 8.18 thickness (mm) Capacity
(g) - Plywood (kN/ml
Plywood shall be nailed fo frame using 30 x 2.8mm dia. flathead naits or equivatent Stud
For Method A,M12 rods shall be used at each end of sheathed section top st spacing
plate to bottom plate/floor frame. Method B has no rods but sheathing shalt ress {mm}
be nailed to top & bottom plates and any horizontal joints at 50mm crs. grade
Horizontat butt joints permitted, provided nai 450 600
fixed to nogging at s = 150mm cers for
Method A, or s = SOmm crs for Method B FB 7 9
/ Pa an = FN 6 1
150 T it | Fis 4 6
} . 5 } F27 4 45
| r Tt , 1 Fastener spacing, s
« 300mm. +} : + inl °
: { : toe
1 . : : + - Top and Method
F . 1 ‘ 1 bottom plate Aba
s . | = Method A 150 | Method
} : . + - Method B so | 8 6.0
Sheathed } : + Vertical
panels shali r . 1 edges 150
beconnected = | : 1 : . 4
to subfloor fe see fe
For Method A only; Intermediate
M12 rod to top & bottom plate studs 300
each end of sheathed section
NOTE: For plywood fixed to both sides of wall, see Clause 8.3.6.5
Steel Braces on Timber or Steet Columns
where bearer height to width
exceeds 4:1 the bearer shall be
fixed to prevent overturning
, crf
———__——_—___2/M 12 or 1/M16
2/30 x 0.8 galv straps, 4/2.8 bolt to bearer
Rails each end for hardwood and footing
5/2.8 nails for softwood FOOTING DEPTH IN M16 rod 1
FIRM {OR STRONGER} MAXIMUM TIE-DOWN rods, circular
LOW TO MEDIUM FORCE “U" (kN) hollow or rectangular
2 nailing plates ea. end M10 bolt PLASTICITY CLAYimm) holiow sec
of bridging, legs not bent 3 450 11.25
with 6/2.8 nails ea. face X 600 15.0 =
a 750 18.75 ——\!_——— column
3] mm 900 22.5
For each square
a metre of 190mm 2s 60° MAX
concrete slab . 30" MIN concrete stab optional
. tied te footing
100x50mm bridging F +
BRACING WALL TO FLOOR JOISTS piece on edge I | x
, bracing rods shall be tensioned 1 | ej£ 8
DESIGN STRENGTH {kN) I L { 5 a+
BRACING WALL TO EXTERNAL WALL Fe Ux D/titean oa g|8 &
r— Mi0 bolt with maximum of L J o
15 KN per set y
po
M { X
TO FLOOR JOISTS
BRACING WALL Double joist or 450mm long
full depth cleat nailed to
joist with 6/75x3.15mm dia. nai
‘AMENDMENT PHILL McGOWAN DRAFTING GBSA No 525708 Y
This drawing remains the propert
and may not be used oF reproduc
COPYRIGHT:
t Austratian Independent Builders,
whole or in part without written permission.
102 Fairview Rd Gympie 4570 Phone 9754828350 Mobile 0429645361 Email [email protected]
Project PROPOSED RELATIVES APARTMENT
Location 61LAKE FLAT ROAD BOREEN POINT
Drawing BRACE DETAILS
building designers Drawn P.M.
essociation of
queensland inc.
Client R.& D. HAMMERSLEY 01088
Scale - Date 19/11/08 Sheet 10 OF 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/0152 - MCU - Mulitple Housing Type 1 - Relative or Employee [As Published]Related documentApplication case desk ↗
0019DC6E.001.pdfRelated documentPublic source context ↗
About this file
- File size
- 4.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.