MATERIALS AND FINISHES
CODE DESCRIPTION FINISH FT3 2m Powdercoated Aluminium Screen XXXX
AWN1 Awning Hood Powder Coated Aluminium Surfmist PV1 Feature Driveway Entry Beauford Crazy Pave
AWN2 Awning Hood Powder Coated Aluminium Surfmist RN1 Render Resene Black White
BAL3 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN2 Render with Sawcuts Concrete Look
BAL4 Solid Balustrade Birch RN3 Render with Sawcuts To Match Surfmist
BAL5 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN4 Render over cladding Resene Black White
BAL6 Aluminium and Translucent glass balustrade Powder Coated Aluminium Surfmist RN5 Render with Sawcuts over cladding Concrete Look
CLD1 Hardies Oblique XXXX RS1 LYSAGHT Colorbond roof sheet Colorbond Surfmist
CLD2 External Feature Walls - Territory Panel Limed SCN1 Aluminium Batten Screen - angled Powder Coated Aluminium Surfmist
EA CONC Driveway; Exposed Aggregate Concrete Silver Frost SF1 Soffit lining Resene Black White
EG1 Eaves Gutter Stratco Colorbond Surfmist SF2 Soffit lining Pre-finished
EG2 Custom Profile Eaves Gutter Colorbond Surfmist SF3 Soffit lining - Territory Panel Limed
FF1 External Tile Paradise Stone Ivory
FT1 2m High Perimeter Fencing Timber Pailing Resene Black White
FT2 1.4m Screen above Rendered Blockwork XXXX
FT3 2m Powdercoated Aluminium Screen XXXX
V V
4.2 3.2 2.2 1.2 A.2 B.2 C.2 D.2 E.2 F.2 G.2
8M HEIGHT LIMIT POOL UNIT 201 & 205 UNIT 202 & 205 UNIT 203 & 206 TOWNHOUSE 207
SCIA
TOWNHOUSE 207 TOWNHOUSE 207 FA 8M HEIGHT LIMIT 8M HEIGHT LIMIT
AT FASCIA AT ROOF RIDGE
RS1 RS1
EG1
EG1 EG1 EG1 EG1 CLD2
2400 WINDOW & RN2 RN2 RN2
W.03 W.17 W.01
DOOR HEAD HEIGHT
TERRACE TERRACE TERRACE
EG1
AD.22 AD.21 AD.22
CLD2 EG1 UPPER LEVEL EG1
EG1 CLD2 RN4 Bal3 Bal3 RN4
FFL+15.470 Bal3 CLD2
2400 WINDOW & 2400 WINDOW &
DOOR HEAD HEIGHT W.11 DOOR HEAD HEIGHT
RN1 RN1 RN1 RN1
2400 WINDOW & RN1
AD.04 RN4
UPPER LEVEL DOOR HEAD HEIGHT TERRACE CL TERRACE CL TERRACE CL
AD.06 UPPER LEVEL
W.07 W.07
FFL+13.420 Bal6 FFL+13.440
Bal6 SCN3 SCN3 SCN3
GROUND LEVEL
FFL+12.500 AD.22 W.04 AC W.18 AD.21 AD.22 W.04
AC RN4 CLD2 RN1
2400 WINDOW & 2400 WINDOW &
DOOR HEAD HEIGHT W.11 RN1 RN1 NATURAL GROUND DOOR HEAD HEIGHT
FINISHED GROUND
RN1 CL
SHS SHS SHS
SHS
GROUND LEVEL GROUND LEVEL
AC NATURAL GROUND FENCE SHOWN DASHED
FFL+10.320 FFL+10.340
AD.19 AD.19 D.12 AD.10
FINISHED DRIVEWAY
FINISHED DRIVEWAY
FINISHED GROUND
NATURAL GROUND
N BUILDING 2 ELEVATION E BUILDING 2 ELEVATION
- Scale 1:100 - Scale 1:100
G.2 F.2 E.2 D.2 V C.2 B.2 A.2
1.2 2.2 3.2 4.2 TOWNHOUSE 207 UNIT 203 & 206 UNIT 202 & 205 UNIT 201 & 204 POOL
V
8M HEIGHT LIMIT
8M HEIGHT LIMIT
RS1 RS1
EG1 EG1 EG1
EG1 EG1 EG1 CLD2 EG1 EG1
CLD2
AWN1 AWN2 AWN2 EG1
AWN1
2400 WINDOW & 2400 WINDOW &
W.01 RN2 W.02 W.02 W.17 W.03 W.17 SCN5
DOOR HEAD HEIGHT DOOR HEAD HEIGHT
EG1 SCN5
SCN5 D.11 D.12 D.11
UPPER LEVEL EG1 UPPER LEVEL
CLD2
FFL+15.470 FFL+15.470
2400 WINDOW &
RN4 RS1 EG1 RS1 EG1
DOOR HEAD HEIGHT
AWN1 AWN2 AWN2
AWN1
RN1 2400 WINDOW & 2400 WINDOW &
W.01 W.02 W.02 W.17 W.03 W.17
DOOR HEAD HEIGHT UPPER LEVEL W.19 AD.07 DOOR HEAD HEIGHT
Bal6 RN1 D.11
FFL+13.440 Bal6 D.12
CLD2 D.12
RN1
MP GROUND LEVEL RN1 RN1 RN1 RN1 GROUND LEVEL
D.11 FFL+12.500 RN1 FFL+12.500
2400 WINDOW &
DOOR HEAD HEIGHT CL
NATURAL GROUND FINISHED DRIVEWAY
NATURAL GROUND GROUND LEVEL RN1
AC W.05
FINISHED DRIVEWAY
FFL+10.340 W.05 W.05
D.16
FINISHED GROUND
S BUILDING 2 ELEVATION
- Scale 1:100
W BUILDING 2 ELEVATION
- Scale 1:100
Notes:
B L A C K Project: Drawing Title: Project No. Drawn By Drawing No.
Rev Date Description Use figured dimensions in preference to scale. Contact information:
1. These drawings represent a concept design for preliminary cost analysis (MAY 2023) and are NOT FOR CONSTRUCTION R 4/03/2024 Updated Building Layout Submission All dimensions to be varified and checked on
S 10/04/2024 UPDATED COUNCIL RFI site. These designs, drawings, specifications
PO Box 781 Tewantin Q 4565 79 - 83 Eumundi Noosa Road B2 - ELEVATIONS 202327 PT WD.2.06
2. The drawings and diagrams provided herewith are NOT FOR CONSTRUCTION OR BUILDING APPROVAL and to be used for preliminary D&C tendering only. Architect Registration # 5386 QLD
and the copyright thereof are the property of For CAPITAL PRUDENTIAL
Structure & Services coordination has not been undertaken.
T
U
24/04/2024
16/10/2024
Update to Builder
Decision Notice Amendment Issue
Blackwood and must not be used, retained or W O O D Ph: 0416 037 424
[email protected] 79 - 83 EUMUNDI NOOSA ROAD & 26 Scale Date Project Stage Revision
copied without the written authority of
V 8/11/2024 Roof Revision Issue Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au HEADLAND DRIVE, NOOSAVILLE QLD 4566 1:100, 1:1 @ A1 8/11/2024 Design Development V