Approval from Unitywater for driveway design over sewer

Attached to the e-mail Operational Works Application OPW21/0063 - Cover letter - DA Form 1 - Plans - Correspondence with Unitywater - 16 Myles Street Cooroy.

of 6

Page text shows just the words. Original shows the document exactly as it was published.

Doug Reynolds

From:                             Jarrod Murphy <[email protected]>
Sent:                             Tuesday, 23 February 2021 8:11 AM
To:                               Doug Reynolds
Subject:                          RE: 20651 - 16 Myles St, Tewantin - driveway
Attachments:                      20651_CIVIL-C1100.pdf


Hi Doug

This sewer protection design satisfies the Unitywater requirements.

Kind Regards

Jarrod Murphy | Principal Development Engineer
Development Services
Sustainable Infrastructure Solutions
Unitywater
PO Box 953 Caboolture Qld 4510
m: 0407 953 054
e: [email protected]




From: Doug Reynolds <[email protected]>
Sent: Tuesday, 16 February 2021 3:26 PM
To: Jarrod Murphy <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway

Hi Jarrod,

Further to our discussions last month please find attached detailed design for the driveway at 16 Myles Street Tewantin.
Can you please review and provide approval with respect to the cover and bridging detail over the sewer main. Note we
are hoping to avoid any lowering of the sewer manhole but that will depend on whether the verge grades are
acceptable to Council. Thanks Jarrod


Thanks and Regards
Doug Reynolds, Director – Civil Group, B.Eng (Civil), RPEQ, Member IPWEAQ, Member AIPM




                                                           1
Log in to download the original file

Approval from Unitywater for driveway design over sewer.pdf · 945 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 5 pages

Page 2

0488 383 370 | [email protected]
Noosa: 07 5449 9600 Sunshine Coast: 07 5329 3190
TOD Consulting Pty Ltd, PO Box 61, Noosaville QLD 4566

2016 IPWEAQ Award winner (Projects $2Million - $5Million) – Curing a Cancer Patient: Munna Point Bridge




From: Jarrod Murphy <[email protected]>
Sent: Monday, 18 January 2021 3:20 PM
To: Doug Reynolds <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway

I think it should have Unitywater approval. Send through design to me and I’ll attend to it.

Kind Regards

Jarrod Murphy | Principal Development Engineer
Development Services
Sustainable Infrastructure Solutions
Unitywater
PO Box 953 Caboolture Qld 4510
m: 0407 953 054
e: [email protected]




From: Doug Reynolds [mailto:[email protected]]
Sent: Monday, 18 January 2021 12:00 PM
To: Jarrod Murphy <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway
                                                              2

Page 3

Thanks Jarrod,

No connection application just driveway and footpath works. Do we need your sign off once the detailed design is
done? It is being submitted to Council for approval.

Doug

From: Jarrod Murphy <[email protected]>
Sent: Monday, 18 January 2021 10:36 AM
To: Doug Reynolds <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway

Hi doug

Yep. Spot on. Are these works associated with a connection application? Or is it just a driveway and footpath
augmentation?

Kind Regards

Jarrod Murphy | Principal Development Engineer
Development Services
Sustainable Infrastructure Solutions
Unitywater
PO Box 953 Caboolture Qld 4510
m: 0407 953 054
e: [email protected]




From: Doug Reynolds [mailto:[email protected]]
Sent: Friday, 15 January 2021 1:54 PM
To: Jarrod Murphy <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway

Thanks Jarrod,

I have added what I think will be necessary in regards to piers – do you agree?

Doug

From: Jarrod Murphy <[email protected]>
Sent: Friday, 15 January 2021 1:26 PM
                                                            3

Page 4

To: Doug Reynolds <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway

Hi Doug

I can confirm that the standard crossover will be fine with having a structural concrete path with concrete footings each
side of sewer to avoid any loading impact.

Any alteration to the Unitywater infrastructure like manhole lowering or connection moving etc needs to be applied
through the Unitywater Private works area.

Kind Regards

Jarrod Murphy | Principal Development Engineer
Development Services
Sustainable Infrastructure Solutions
Unitywater
PO Box 953 Caboolture Qld 4510
m: 0407 953 054
e: [email protected]




From: Doug Reynolds [mailto:[email protected]]
Sent: Friday, 15 January 2021 9:18 AM
To: Jarrod Murphy <[email protected]>
Subject: FW: 20651 - 16 Myles St, Tewantin - driveway

Hi Jarrod,

Hope you had a great Christmas and New Year. I am starting the year with a request for some advice. We have been
engaged to design a driveway for an existing vacant lot at 16 Myles St Tewantin. The verge profile is non compliant with
the footpath level approx. 400mm above the top of kerb. There is a sewer located in the verge that is only 1.3m deep. If
we were to construct a standard driveway profile across the verge then the cover over the sewer would be reduced to
540mm. We also looked at a non standard crossover (bridged crossover) that would improve the cover to 800mm which
we appreciate is still not complaint. Refer options drawing attached. Council have indicated that their preference is for
the driveway to be constructed to the standard profile so we need Unitywater approval for the reduced cover over the
sewer (540mm). Refer email trail below. Note that there is little opportunity to lower the sewer to improve the
situation. Can you please advise if Unitywater would accept the reduced cover in this location?

Thanks for your assistance.



                                                            4

Page 5

Thanks and Regards
Doug Reynolds, Director – Civil Group, B.Eng (Civil), RPEQ, Member IPWEAQ, Member AIPM




0488 383 370 | [email protected]
Noosa: 07 5449 9600 Sunshine Coast: 07 5329 3190
TOD Consulting Pty Ltd, PO Box 61, Noosaville QLD 4566

2016 IPWEAQ Award winner (Projects $2Million - $5Million) – Curing a Cancer Patient: Munna Point Bridge




From: Mark Lewis <[email protected]>
Sent: Thursday, 14 January 2021 9:12 AM
To: Doug Reynolds <[email protected]>
Subject: RE: 20651 - 16 Myles St, Tewantin - driveway

Doug, the other relevant sections are not supportive of build outs or encroachments on to the road pavement
so your option 2 is preferred. There is a question regarding the existing street that is not indicated on the
design plans. Is your client considering seeking approval to remove the tree?

Thanks

Mark

From: Doug Reynolds <[email protected]>
Sent: Tuesday, 12 January 2021 9:26 AM
To: Mark Lewis <[email protected]>
Subject: 20651 - 16 Myles St, Tewantin - driveway

Hi Mark,

We have been engaged to design a driveway into an existing lot at 16 Myles Street, Tewantin. I understand the architect
Dale Webb from Rufous Design may have already had discussions with you about this. The site is very difficult as the
verge profile is non-compliant and the existing footpath resides approx. 400mm above the top of kerb. We have
produced the attached drawing showing the levels for a compliant driveway and for an alternative utilising a bridging
detail at the kerb based on a Gympie Regional Council standard drawing (also attached). As you can see with the
standard profile the cover over the sewer is compromised (less than UW requirements) and there is no way of lowering


                                                              5

Page 6

the sewer to increase the cover. As such can you advise if Council would support the bridging option for the driveway.
Note that the neighbouring property to the north has a similar, albeit it poor, bridging access.


Thanks and Regards
Doug Reynolds, Director – Civil Group, B.Eng (Civil), RPEQ, Member IPWEAQ, Member AIPM




0488 383 370 | [email protected]
Noosa: 07 5449 9600 Sunshine Coast: 07 5329 3190
TOD Consulting Pty Ltd, PO Box 61, Noosaville QLD 4566

2016 IPWEAQ Award winner (Projects $2Million - $5Million) – Curing a Cancer Patient: Munna Point Bridge




Disclaimer

The information contained in this communication from the sender is confidential. It is intended solely for use by
the recipient and others authorized to receive it. If you are not the recipient, you are hereby notified that any
disclosure, copying, distribution or taking action in relation of the contents of this information is strictly
prohibited and may be unlawful.



                                                    Click here to report this email as spam.



Unitywater Privileged, Private and Confidential - This email and any attachments may contain legally privileged or confidential information and may
be protected by copyright. You must not use or disclose them other than for the purposes for which they were supplied. The privilege or confidentiality
attached to this message and any attachments is not waived by reason of mistaken delivery to you. If you are not the intended recipient, you must not
use, disclose, retain, forward or reproduce this message or any attachments. If you receive this message in error please notify the sender by return
email or telephone and destroy and delete all copies.

Unitywater carries out monitoring, scanning and blocking of emails and attachments sent from or to addresses within Unitywater for the purposes of
operating, protecting, maintaining and ensuring appropriate use of its computer network.

It is recommended that you scan this email and any attachment before opening. Unitywater does not accept any responsibility or liability for loss or
damage arising directly or indirectly from opening this email, any attachments or any communication errors.




                         This message has been scanned for malware by Websense. www.websense.com

                                                                            6

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.