         GENERAL                                                                                             DIMENSIONS/LEVELS                                                                                              TIMBER FRAMING & BRACING:                                                                                ABBREVIATIONS:
         G1      STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE                                   L1.    CONSTRUCTION SHALL BE SET OUT USING SURVEY BENCHMARKS PROVIDED BY COUNCIL.                              T1      ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 1720, AS 1684                       A.C.F. -     ALL CORES FILLED
                 SPECIFICATION, ARCHITECTURAL, AND OTHER CONSULTANTS' DOCUMENTS.                                                                                                                                                    AND THE REFERENCED STANDARDS THEREIN.                                                            BTM.     -   BOTTOM
                                                                                                             L2.    ALL LEVELS AND SETOUT POINTS ARE SHALL BE CONFIRMED ON SITE BY REGISTERED                                                                                                                                        B.W.     -   BOTH WAYS
         G2       REFER TO THE ARCHITECTURAL DRAWINGS FOR SETOUT. NO DIMENSIONS SHALL BE                            SURVEYOR PRIOR TO CONSTRUCTION. ADVISE ANY DISCREPANCY BEFORE PROCEEDING.                               T2      ALL FRAMING, BRACING AND TIE-DOWN INFORMATION FORMS THE BASIS OF THE                             CB       -   CONSTRUCTION BREAK
                  OBTAINED BY SCALING FROM DRAWINGS.                                                                                                                                                                                STRUCTURES STABILITY DOWN TO FOUNDATIONS. ALTERNATIVE METHODS SHALL                              C.O.S. -     CONFIRM ON SITE
                                                                                                             L3.     DIMENSION STANDARDS:                                                                                           ONLY BE ACCEPTED ON APPROVAL OF THE ENGINEER.                                                    D&C      -   DESIGN & CONSTRUCT
         G3      UNLESS OTHERWISE NOTED (UNO), ALL LEVELS ARE IN METRES AND ALL DIMENSIONS ARE IN                   - REDUCED LEVELS, CHAINAGES AND COORDINATES ARE ALL IN METRES.
                                                                                                                                                                                                                                                                                                                                     DWG      -   DRAWING
                 MILLIMETRES.                                                                                       - CIVIL DRAWINGS (SKC SERIES): ALL OTHER DIMENSIONS ARE IN METRES (m).                                  T3      PREFABRICATED TIMBER ROOF TRUSSES, PROPRIETARY FLOOR JOIST SYSTEMS
                                                                                                                                                                                                                                                                                                                                     E.F.     -   EACH FACE
                                                                                                                    - STRUCTURAL DRAWINGS (SKS SERIES): ALL OTHER DIMENSIONS ARE IN MILLIMETRES (mm).                               AND ALTERNATIVE TIMBER ELEMENTS TO THOSE SHOWN ON THE ENGINEERING
                                                                                                                                                                                                                                                                                                                                     H.D.G. -     HOT DIP GALVANISED
         G4       THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STABILITY OF THE                                                                                                                                          DRAWINGS ARE TO BE DESIGNED AND CERTIFIED BY THE SUPPLIER'S STRUCTURAL
                 STRUCTURE UNTIL ITS COMPLETION AND SHALL ENSURE THAT NO PART OF THE STRUCTURE               L4.    ALL LEVELS ARE TO AUSTRALIAN HEIGHT DATUM.                                                                      ENGINEER. DESIGN AND INSPECTION CERTIFICATES FOR THESE ELEMENTS ARE TO BE                        Lg.      -   LONG
                 IS OVER-STRESSED BY EXCESSIVE LOADING.                                                                                                                                                                             ISSUED TO THE CONTRACTOR FOR LODGEMENT WITH THE LOCAL AUTHORITY.                                 L.V.     -   LENGTH VARIES
                                                                                                             L5.    DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS.                                                                                                                                                                    N.S.O.P. -   NOT SHOWN ON PLAN
         G5      ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE CURRENT VERSION                                                                                                                              T4      ALL TIMBER MEMBERS USED ARE TO HAVE A MINIMUM LEVEL OF DURABILITY AS                             SS       -   STAINLESS STEEL
                 OF THE APPLICABLE STANDARD EXCEPT WHERE VARIED BY THE SPECIFICATION AND/OR                  L6.    DESIGN USES DIGITAL TERRAIN MODEL GENERATED FROM THE SITE SURVEY. SOME                                          SPECIFIED IN AS1684.2 - APPENDIX B.                                                              TYP.     -   TYPICAL
                 DRAWINGS. APPLICABLE CODES OF PRACTICE INCLUDE BUT ARE NOT LIMITED TO THE                          ELEMENTS ARE INTERPOLATED AND MAY VARY FROM THE ACTUAL SITE CONDITIONS                                                                                                                                           U.N.O. -     UNLESS NOTED OTHERWISE
                 FOLLOWING:                                                                                                                                                                                                 T5      ALL HWD TIMBER SHALL BE SEASONED UNO.                                                            V        -   VARIES
                 AS 1163        STRUCTURAL STEEL HOLLOW SECTIONS
                 AS 1170        SAA LOADING CODE                                                                                                                                                                            T6      ALL TIMBER SHALL BE FREE OF GUM VEINS, KNOTS, SHAKES, CHECKS, WANES AND ANY
                 AS 1554        WELDING OF STEEL STRUCTURES                                                  CONSTRUCTABILITY CONSTRAINTS:                                                                                          OTHER IMPERFECTIONS WITHIN CONNECTION ZONES.
                 AS 1664        ALUMINIUM STRUCTURES
                 AS 1684        RESIDENTIAL TIMBER-FRAMED CONSTRUCTION                                       CC1. CONSTRUCTABILITY CONSTRAINTS:                                                                             T7      ALL TIMBER FRAMING TO BE MINIMUM H6 TREATED UNO.
                 AS 1720        TIMBER STRUCTURES
                 AS 2159        PILING CODE                                                                    A)   PROTECT ALL EXISTING INFRASTRUCTURE (EG CULVERT CROSSING, PAVEMENTS,                                    T8      EXPOSED FRAMING (TIMBER FRAMING THAT MAY BE SUBJECT TO PERIODIC WETTING):
                 AS 4100        STEEL STRUCTURES                                                                    FENCING & ELECTRICAL POLES/WIRES) FROM ANY DAMAGE.                                                                  - SHALL BE EITHER H6 PRESSURE TREATED OR DURABILITY CLASS 1
                 AS 4997        GUIDELINES FOR THE DESIGN OF MARITIME STRUCTURES                                                                                                                                                          SPECIES (MINIMUM) SAWN TIMBER (UNO)
                 AS 5100        BRIDGE DESIGN                                                                 B)    ALLOW OF LIKELIHOOD OF FLOW WITHIN THE WATERWAY: EXISTING WATERWAY ARE
                 BCA           BUILDING CODE OF AUSTRALIA (NATIONAL CONSTRUCTION CODE)                              FLOODED MULTIPLE TIMES PER YEAR. PROTECT CONSTRUCTION EQUIPMENT AND                                     T9      WASHERS SHALL BE PROVIDED UNDER ALL NUTS AND BOLT HEADS (EXCEPT CUP-HEAD
                                                                                                                    WORKS.                                                                                                          BOLTS) BEARING AGAINST TIMBER AS FOLLOWS:
         G6      ANY DISCREPANCY SHALL BE REFERRED TO THE SUPERINTENDENT FOR A DECISION BEFORE                                                                                                                                          BOLT SIZE      WASHER
                 PROCEEDING WITH THE WORK.                                                                   CC2. NO WORK TO COMMENCE ON SITE UNTIL:                                                                                    <=M12           50X50X3.0mm
                                                                                                                                                                                                                                           M16         57X57X4.0mm
                                                                                                                  - OFFICIAL PRE-START MEETING HELD AND PRE-START MEETING MINUTES ISSUED
         G7      ALL PROPRIETARY PRODUCTS NOT DEEMED TO COMPLY WITH THE BCA SHALL HAVE                                                                                                                                                     M20         65X65X5.0.mm
                                                                                                                  - CONTRACTOR'S MANAGEMENT PLANS SUBMITTED (SITE, TRAFFIC, ENVIRONMENT,
                 THIRD-PARTY CERTIFICATION WITH RELEVANT TESTING AND SIGN-OFF BY AN RPEQ ENGINEER.                                                                                                                                       >M20           75X75X6.0mm
                                                                                                                  SAFETY) FOR SUPERINTENDENT'S REVIEW.
                 PROPRIETARY PRODUCTS INCLUDES PREFABRICATED TRUSSES, LIGHT-GAUGE STEEL
                 FRAMING, FLOORING PRODUCTS, RECYCLED TIMBER AND PLASTICS, BALUSTRADES, SCREENS,                                                                                                                            T10     X….. INDICATES M12DIA ANCHOR ROD/BOLT
                 SHADE FABRICS, JOINERY, PARTITIONS AND OPERABLE WALLS.
                                                                                                                                                                                                                            T11     [X]….. INDICATES M16DIA ANCHOR ROD/BOLT
         G8      REFER TO ARCHITECTS DRAWINGS FOR DETAILS OF ALL GROOVES, FILLETS, HOBS, DRIP
                                                                                                             DRIVEN PILES:
                 GROOVES AND THE LIKE.                                                                                                                                                                                      T12     SB…. INDICATES STRAP BRACE ROOF BRACING FIXED TO TOP OF EACH JOIST WITH 2
                                                                                                             P1.    PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH AS2159.                                                           SCREWS. BEND STRAP BRACING OVER AT ENDS, FIX WITH 2 SCREWS TO TOP OF JOIST
         G9       GIVE AT LEAST 24 HOURS NOTICE OF AN INSPECTION BEING REQUIRED FOR :                                                                                                                                               AND 4 SCREWS TO SIDE FACE OF SUPPORTING MEMBER. ALL ROOFS TO BE BRACED.
                                                                                                             P2.    CONSTRUCTION CONSTRAINTS: AVOID LOADING EXISTING REVETMENT WALLS.
                 - PILING
                 - JETTY FRAMING (TIMBER)                                                                                                                                                                                   T13     ALL FASTENERS ARE TO BE GRADE A4-70 STAINLESS STEEL IN ACCORDANCE WITH
                                                                                                             P3.    DESIGN LOADS: PILES TO ACHIEVE GEOTECHNICAL CAPACITIES (VERTICAL &                                              ISO-3506-1. EXTERNAL ANCHORS WHERE SUBJECT TO SALT AIR SHALL BE STAINLESS
                 - BRACING AND TIE DOWN
                                                                                                                    HORIZONTAL) SHOWN ON THE DRAWINGS                                                                               STEEL A4-70:
         G10     ALL FABRICATION SHOP DRAWINGS SHALL BE PROVIDED TO THE ENGINEER FOR REVIEW AND                                                                                                                                          -SCREWS TO BE NO.14 TYPE 17 WITH 50MM EMBEDMENT (UNO)
                                                                                                             P4.    REQUIRED PILE POSITION TOLERANCES:                                                                                   -ALL JOIST HANGERS, FRAMING ANCHORS, TRIPLE GRIPS AND THE LIKE, SHALL BE
                 COMMENT IN A3 HARDCOPY OR PDF FORMAT.
                                                                                                                                                                                                                                         STAINLESS STEEL. TO BE MANUFACTURED BY PRYDA OR APPROVED
                                                                                                                    PLAN POSITION: +/- 50mm AT UNDERSIDE OF EACH GROUND BEAM.                                                            EQUIVALENT, WITH 5 NO. 2.8mm DIA X 30MM
         G11     ABBREVIATIONS (GENERAL):
                                                                                                                    PILE VERTICALITY:                                                                                                    NAILS EACH LEG MINIMUM. INSTALL AS PER MANUFACTURERS SPECIFICATION.
                 NTS      NOT TO SCALE
                                                                                                                    - WITHIN 4% FOR ALL PILES
                 UNO      UNLESS NOTED OTHERWISE
                 NSOE     NOT SHOWN ON ELEVATION                                                                                                                                                                            T14     PROVIDE BLOCKING OVER SUPPORTS AT 1800 MAX CRS IN ACCORDANCE WITH AS 1684
                                                                                                             P5.    PILE TOE LEVELS ON THE DRAWINGS ARE ESTIMATED LEVELS. ACTUAL TOE LEVELS                                         FOR TIMBER BEARERS AND JOISTS WITH D/B >= 4.
                 NSOP     NOT SHOWN ON PLAN
                                                                                                                    SHALL BE DETERMINED DURING CONSTRUCTION BY AN RPEQ-CERTIFIED
                 TYP      TYPICAL
                                                                                                                    GEOTECHNICAL ENGINEER.                                                                                  T15     FOR JOISTS WITH SPAN >3000 AND BOTTOM OF JOIST UNRESTRAINED BY CEILING
                 (O)      OVER
                 (U)      UNDER                                                                                                                                                                                                     DIAPHRAGM:
                                                                                                             P6.    DO NOT FOUND PILES HIGHER THAN TOE LEVELS ON DRAWINGS, UNLESS APPROVED BY                                            -PROVIDE 1 ROW OF BLOCKING BETWEEN EACH JOIST AT
                 CRS      CENTRES
                                                                                                                    BOTH THE SUPERINTENDENT AND THE GEOTECHNICAL ENGINEER. THE                                                               MIDSPAN FOR SPANS < 4200mm
                 NOM      NOMINAL
                                                                                                                    SUPERINTENDENT SHALL SEEK ADVICE FROM THE DESIGN ENGINEER AS REQUIRED.                                               -PROVIDE 2 ROWS OF BLOCKING BETWEEN EACH JOIST AT
                 CFW      CONTINUOUS FILLET WELD
                                                                                                                                                                                                                                             THIRD POINTS FOR SPANS >4200mm

                                                                                                                                                                                                                            T16     FIXING LOCATIONS TO BE FIXED ACCORDING TO THE FOLLOWING MINIMUM PACINGS
         DESIGN CRITERIA                                                                                     ALUMINIUM:                                                                                                             (D = FIXING SHANK DIA. IN mm):
                                                                                                                                                                                                                                    BOLTS       4D  EDGE DISTANCE TO BOTH EDGES IN DIRECTION OF SHEAR LOAD
         DC1 THE STRUCTURAL ELEMENTS HAVE BEEN DESIGNED FOR THE FOLLOWING LIVE LOADS                         A1.    ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH BEST PRACTISE ALUMINIUM                                                    5D   PITCH BETWEEN BOLTS
             IN ACCORDANCE WITH AS 1170.1: LIVE LOAD REDUCTIONS ARE NOT APPLICABLE.                                 FABRICATION AND THE CURRENT AUSTRALIAN STANDARD AS 1664.                                                                   5D   EDGE DISTANCE FROM END OF ELEMENT
             ELEMENT            UDL         CONCENTRATED                                                     A2.    ALUMINIUM SECTIONS SHALL COMPLY WITH AS 1734, AS 1886 OR AS 1867.                                                          13D MINIMUM OVERALL ELEMENT DEPTH
             DECK               2.0kPa      2.7KN                                                            A3.    ALL WELDING SHALL COMPLY WITH AS 1665.
                                                                                                             A4.    ALL WELDING SHALL BE CARRIED OUT USING ARGONGAS SHIELDING. WELD
         DC2 WIND LOADS HAVE BEEN DETERMINED IN ACCORDANCE WITH AS 1170.2 BASED ON:                                                                                                                                          MINIMUM SPACING, EDGE & END DISTANCES FOR NAILS AND SCREWS
                                                                                                                    CONSUMABLES SHALL BE COMPATIBLE WITH BOTH PARENT ALLOYS IN ACCORDANCE
             IMPORTANCE LEVEL            2                                                                          WITH AS AS 1665. FOR 6063-T6 USE 4043 FILLER WIRE. PLATE-TO-EXTRUSION ALLOYS
             REGION                      B                                                                                                                                                                                                                     MINIMUM DISTANCE
                                                                                                                    SHALL BE WELDED USING APPROPRIATE FILLERS IN ACCORDANCE WITH WTIA
             ULTIMATE WIND SPEED         51 m/s                                                                     TECHNICAL NOTES WHERE NOT COVERED BY AS 1665.
             SERVICEABILITY WIND SPEED   39.0 m/s                                                                                                                                                                             SPACING TYPE        HOLES FOR                      HOLES FOR
                                                                                                             A5.    ALL WELDS SHALL BE A MINIMUM 5mm CONTINUOUS FILLET WELD ALL ROUND,
             TERRAIN CATEGORY           1.5                                                                                                                                                                                                       NAILS NOT                      NAILS PREBORED SCREWS
                                                                                                                    UNLESS NOTED OTHERWISE.
                                                                                                                                                                                                                                                  PREBORED                       TO 80% DIA.
                                                                                                             A6.    ALUMINIUM EXTRUSIONS SHALL BE STRUCTURAL GRADE ALLOY:- EXTRUSIONS 6063-T6
         DC3 EARTHQUAKE LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 1170.4 BASED                                                                                                                                        END DISTANCE          20D                               10D        10D
                                                                                                                    UNLESS NOTED OTHERWISE.
             ON:                                                                                                                                                                                                              EDGE DISTANCE          5D                                 5D        5D
                                                                                                             A7.    ALUMINIUM PLATE IS TO BE WROUGHT GRADE ALLOY 5083 H116.
             ACCELERATION COEFFICIENT    0.06                                                                                                                                                                                 ALONG-GRAIN SPACING   20D                                10D       10D
                                                                                                             A8.    ALL STEEL AND STAINLESS STEEL BOLTS AND ALL OTHER FIXINGS MUST BE ISOLATED
             SITE FACTOR                1                                                                                                                                                                                     CROSS-GRAIN SPACING    10D                               3D         3D
                                                                                                                    FROM ALUMINIUM USING NYLON OR SIMILAR APPROVED PACKERS/GASKETS, AND
             IMPORTANCE LEVEL           1                                                                           WASHERS WITH SHANK COLLARS.
             STRUCTURE TYPE                                                                                  A9.    SHOP DETAIL DRAWINGS ARE TO BE SUBMITTED TO THE ARCHITECT AND ENGINEER
             DESIGN CATEGORY            EDC1                                                                        FOR REVIEW. APPROVAL IS TO BE OBTAINED FROM THE COUNCIL, THE ARCHITECT AND
                                                                                                                    THE ENGINEER, PROIR TO COMMENCING FABRICATION.
         DC4 FIRE RESISTANCE LEVELS OF STRUCTURAL ELEMENTS HAVE BEEN TAKEN AS FOLLOWS:
             ELEMENT        FRL (mins)
             COLUMNS        -/-/-
             BEAMS         -/-/-                                                                             TEMPORARY WORKS:
             WALLS         -/-/-

         DC5 DETERMINATION OF DESIGN LOADING FOR NON-STRUCTURAL ELEMENTS SUCH AS                             T1.    MAINTAIN THE WORKS IN A SAFE CONDITION. ENSURE STRUCTURES ARE NOT
             CEILING AND CLADDING SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR                             OVER-STRESSED AT ANY TIME. TEMPORARY ROAD SURFACES SHALL BE TRAFFICABLE
                                                                                                                    AT ALL TIMES. POTHOLES ETC SHALL BE MONITORED AND REPAIRED.
         DC6 FLOOD LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 5100 WITH NOMINAL
             FLOOD VELOCITY TO BE CONFIRMED BY HYDRAULIC REQUIREMENTS AS FOLLOWS:
                                                                                                             T2.    CONTRACTOR'S RPEQ TO CERTIFY DESIGN AND CONSTRUCTION FOR TEMPORARY
             -V100 = 1m/s.
                                                                                                                    WORKS: STRUTS, PROPPING, FORMWORK STRIPPING AND PROPPING PROCEDURES, TIE                                                                                                                                                                             NOOSA COUNCIL
                                                                                                                    BACKS, EXCAVATION SHORING, PROTECTION WORKS, DE-WATERING SYSTEMS,
                                                                                                                    FORMWORK, EARLY LOADING OF STRUCTURES AND THE LIKE.
                                                                                                                                                                                                                                                                                                                                                                         APPROVED PLAN
                                                                                                                                                                                                                                                                                                                                                                      MCU21/0167 & OPW21/0271
                                                                                                                                                                                                                                                                                                                                                                            18 OCT 2021

                                                    CONSTRUCTION
          © THIS DRAWING IS PROTECTED                                                                ASSOCIATED CONSULTANTS                                                                                                                                    PROJECT                                                               DRAWING TITLE
          UNDER COPYRIGHT IN
          ACCORDANCE WITH
          AGREEMENT BETWEEN
          LODESTAR MERIDIAN PTY LTD
                                                                                                                                     NOOSA JETTY BUILDERS
                                                                                                                                     JOB No:
                                                                                                                                     ADDRESS:
                                                                                                                                                                                               Long View                                                        PROPOSED NEW JETTY
                                                                                                                                                                                                                                                                34 THE PROMONTORY, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                      STRUCTURAL NOTES SHEET
          T/AS LONG VIEW CONSULTING
                                                                                                                                                                                L              Consulting Engineers
                                        REVISIONS




          ENGINEERS AND THE CLIENT AS                                                                                                34 THE PROMONTORY,
          NAMED HEREIN. EXCLUSIVE                                                                                                    NOOSAVILLE.                                               Lodestar Meridian Pty Ltd T/as Long View Consulting Engineers
          USE IS GRANTED UNDER THE
          AGREEMENT ONLY FOR THE                    2   CONSTRUCTION ISSUE         C2      F.M.                                      LOT: 833  SP: 102579                       V              Post:     PO Box 963 Cooroy QLD 4563
                                                                                                                                                                                                                                                               DRAWN
                                                                                                                                                                                                                                                                          S.T.
                                                                                                                                                                                                                                                                                 CHECKED
                                                                                                                                                                                                                                                                                           F.M.
                                                                                                                                                                                                                                                                                                  APPROVED          DATE
                                                                                                                                                                                                                                                                                                                       22/07/2021
                                                                                                                                                                                                                                                                                                                                     SCALE BAR                             DRAWING SCALES
                                                                                                                                                                                                                                                                                                                                                                                             1:1
                                                                                                                                                                                                                                                                                                                                                                                                   DRAWING SIZE
                                                                                                                                                                                                                                                                                                                                                                                                    A1 ORIGINAL
                                                                                                                                     CLIENT: NOEL ROBINSON                                     ABN:      87 711 552 832
          PROJECT. THIS DRAWING SHALL
          NOT BE CONSTRUCTED UNLESS                 1   CONSTRUCTION ISSUE         C1      F.M.                                                                                                Mobile: 0414 681 676
                                                                                                                                                                                                                                                               DESIGNED          CHECKED                            RPEQ / Cert.     PROJECT NUMBER                        DRAWING NUMBER          REVISION
          DESCRIBED AS "CONSTRUCTION                                                                                                                                                           Email:    [email protected]
          ISSUE".                                   No. DESCRIPTION                REV.    APP.                                                                                                Internet: www.longviewconsulting.com.au                                    F.M.             F.M.                              19951                     20.001-023                           S02               C2

Document Set ID: 21641810
Version: 1, Version Date: 08/10/2021
Log in to download the original file

Approved Plans MCU21-0167 & OPW21-0271.pdf · 4.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.