Council archive · source document
21-018 Hiilton CD [E] For OP works · OPW22/0197
General Notes: NOT FOR CONSTRUCTION
Verify all dimensions on site before commencing work or shop
drawings.
Do not scale drawings.
Copyright of Architect: QUOD ARCHITECTURE PTY LTD
The contractor shall carry out works in accordance with the signed
drawings and specifications and anything reasonable inferred, and
with the Conditions of Contract, and in accordance with the
QUOD ARCHITECTURE PTY LTD
directions and to the satisfaction of the Architect, whose
interpretation of the contract documents shall be final.
The drawings and specifications shall be considered
The Gap, QLD 4061
complementary, and any work and/or materials absent from one
T: 0451.511.884
but present or implied in the other shall be furnished as if they were
PO Box 456
present in both.
All work must comply with the National Construction Code Series,
Building Code of Australia and Australian Standards, and all other
relevant by laws and authorities. No work shall be undertaken prior
to approval by a registered Certifier.
M. Pickard and D Perkins
All wet areas are to be waterproofed throughout with a proprietary
waterproofing system installed in accordance with the
27 Hilton Terrace
manufacturers recommendations.
27 HILTON TCE, TEWANTIN
Tewantin
Ceiling linings to be fixed to metal furring channels typically, unless
CLIENT
noted otherwise. DUPLEX DEVELOPMENT
QLD
Provide thermal insulation in accordance with PART 3.12 of the
LOT 106 ON RP 41223
NCCA.
Hilton Terrace
PROJECT NO.
All services shall be concealed in walls or ducts unless noted
PROJECT
otherwise.
Duplex
21-018
All glazing shall comply with AS1288. (Doors and windows subject to
human impact, glazing type and normal thickness Grade A
laminated glass)
DATE: 21,07,22
Construction of sanitary compartment must conform to NCCA
DRAWN BY
3.8.3.3.
ISSUE: E
Supply and install approved smoke detectors to conform with NCCA
3.7.2 requirements to rooms as indicated in AS3786-1993 and as
GF
designated to authority requirements. Multiple alarms to be
interconnected.
The provision of energy efficient lighting to comply with NCCA
3.12.
Plumbing to be carried out by a licensed plumber and in
accordance with the requirement of local authorities. The
contractor shall be responsible for all permits and approvals. All hot
Cover Page
water lines shall be fully insulated. Sanitary Plumbing shall be
connected to existing system with materials approved by the local
authority.
All domestic hot water to basins, showers and baths to comply with
NCCA and relevant standards.
All products to be to manufacturers requirements for exposure
within 1km of coast where applicable.
CD 000
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 15 (of 22)
Page 2
NOT FOR CONSTRUCTION
QUOD ARCHITECTURE PTY LTD
DEMOLISH EXISTING PAVERS & DEMOLISH EXISTING REMOVE ALL STAIRS
CROSSOVER REFER TO HOUSE PAVING &
The Gap, QLD 4061
DRAWING BA202 CONCRETE SLABS
T: 0451.511.884
PO Box 456
SEWER MANHOLE
M. Pickard and D Perkins
HILTON TERRACE
27 Hilton Terrace
Tewantin
CLIENT
QLD
LOT 106 ON RP 41223
Hilton Terrace
PROJECT NO.
PROJECT
Duplex
21-018
DATE: 21,07,22
DRAWN BY
ISSUE: E
GF
EXISTING BUILDING SEWER LINE
TO BE DEMOLISHED
REFER TO ROAD VERGE WORKS PLAN
FOR DEMOLITION TO CROSS OVER
AND FOOTPATH
Demolition Site
SCALE: 1:200 m
Existing /
01 :: EXISTING SITE PLAN
Plan
- scale: 1=200
CD 100
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 3
NOT FOR CONSTRUCTION
QUOD ARCHITECTURE PTY LTD
SEWER LINE
The Gap, QLD 4061
CLEARANCE OVER
SEWER LINE
T: 0451.511.884
PO Box 456
M. Pickard and D Perkins
HILTON TERRACE
27 Hilton Terrace
Tewantin
CLIENT
QLD
LOT 106 ON RP 41223
Hilton Terrace
PROJECT NO.
PROJECT
Duplex
21-018
DATE: 21,07,22
DRAWN BY
ISSUE: E
GF SCALE: 1:200 m
Proposed
Site Plan
CD 200
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 4
NOT FOR CONSTRUCTION
E
QUOD ARCHITECTURE PTY LTD
The Gap, QLD 4061
NEW 1M HIGH RETAINING WALL TO BOUNDARY AS REQUIRED
NEW 1M HIGH RETAINING WALL TO BOUNDARY
T: 0451.511.884
SLAB ON GROUND TO PROPOSED RL: 1.550 CUT TO POOL
PO Box 456
GARAGES & LAUNDRY EXTENT
BLOCKWORK RETAINING
UNDER KITCHEN/ DINING/LIVING AREA
PROPOSED RL: 1.750
PROPOSED RL: 1.900
M. Pickard and D Perkins
HILTON TERRACE
27 Hilton Terrace
EXISTING
FFL: 1.500 NEIGHBOURING
POOL
RL: 1.666
Tewantin
GARAGE LDRY
CLIENT
N AREA TO BE FILLED
S
QLD
GROUND TO WALL 1 IN 100 MIN TO STREET
SHOWN HATCHED
LDRY
462.62 M2
FFL: 1.220 GARAGE
Hilton Terrace
PROJECT NO.
POOL EXISTING
NEIGHBOURING
PROJECT
FFL: 1.500
Duplex
RL: 1.857
21-018
NATURAL GROUND LEVEL
AT RL: 1.900
DATE: 21,07,22
RL: 1.906
EXISTING EXISTING EXISTING
DRAWN BY
NEIGHBOURING BLOCK RETAINING NEIGHBOURING RL: 1.908
NEIGHBOURING
RL: 1.873 WALL TO EXTENT RL: 1.930
RL:1.750 SLAB ON GROUND TO
ISSUE: E
SHOWN TO SUPPORT
EXISTING SLAB TO KIT/DIN/LIV POWDER ROOM AND OUTDOOR SHOWER
01 :: CUT/FILL PLAN NEIGHBOURING RL: 1.901
GF
RL: 1.500 PROPOSED RL: 1.550
SK200 scale: 1=200
NEW 1M HIGH RETAINING WALL TO BOUNDARY NEW 1M HIGH RETAINING WALL TO BOUNDARY
W
SCALE: 1:200 m
Earthworks
Plan
CD 201
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 5
NOT FOR CONSTRUCTION
LAWN /PLANTING
ON ROAD VERGE
FOOT PATH IN FRONT OF
NEIGHBOURING PROPERTY
EXISTING SERVICES PITS
UNALTERED
QUOD ARCHITECTURE PTY LTD
NEW STREET TREE
REFER TO LANDSCAPE ARCHITECTURE PLANS
PEDESTRIAN GATE
The Gap, QLD 4061
PAVING AND CONCRETE CROSSOVER
TO BE REMOVED
T: 0451.511.884
RE-INSTATE KERB AND CHANEL
PO Box 456
NEW LAWN/PLANTING ZONE & FOOTPATH
5046
LETTERBOX
& HOUSE NUMBER
REFER TO DETIALS
GARDEN BED TO STREET FRONTAGE
IN FRONT OF FENCE
M. Pickard and D Perkins
HILTON TERRACE
FENCE RETURN TO MEET VEHICULAR GATE
1000
NEW CONCRETE FOOTPATH
27 Hilton Terrace
WIDTH TO MATCH
500
EXISTING NEIGHBOURING FOOTPATH
NEW CONCRETE CROSSOVER
Tewantin
TO COMPLY WITH STANDARD DRAWING
CLIENT
RS-049 FOR DUPLEX
QLD
WITH FRONTAGE 20 M OR LESS
RL:1.100
RL:1.166
RL:1.220
6000
4000
DOWNPIPE
RL:1.500
RL:1.220
DOWNPIPE
Hilton Terrace
PROJECT NO.
LINE OF SLIDING GATE
PROJECT
Duplex
21-018
NEW CONCRETE FOOTPATH
500
1000
WIDTH TO MATCH
EXISTING FOOTPATHS
EXISTING WATER METER
DATE: 21,07,22
MINOR RELOCATION REQUIRED
REFER TO CIVIL ENGINEERING DOCUMENTS
DRAWN BY
ISSUE: E
5046
LETTERBOX
& HOUSE NUMBER
REFER TO DETAILS
GF
PAVING AND CONCRETE CROSSOVER
TO BE REMOVED
RE-INSTATE KERB AND CHANEL
NEW LAWN/PLANTING ZONE & FOOTPATH
6006
PROPOSED POWER POLE
NEIGHBOURING CROSSOVER
EXISTING POWER POLE
SCALE: 1:100 m
Road Verge
Proposed
Works to
1500 1500 628
01 :: PROPOSED FLOOR PLAN
- scale: 1=100 4043 7500 DRAWINGS TO BE READ IN CONJUCTION WITH CIVIL ENGINEERING AND
LANDSCAPE ARCHITECTURE - REFER TO OPERATIONAL WORKS APPROVAL
CD 202
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 6
NOT FOR CONSTRUCTION
A B C D E F
6000 1500 6180 1534 2655 11630
GARDEN BED TO STREET FRONTAGE
BINS SCREENING
IN FRONT OF FENCE
REFER TO DETAILS
LETTERBOX
& HOUSE NUMBER
ENTRY GATE
PEDESTRIAN GATE REFER TO DEAILS
REFER TO DETAILS
E
COLUMNS TO PERGOLA CLOTHES LINE
STRUCTURE TO /SUPPORT
QUOD ARCHITECTURE PTY LTD
TO UPPER LEVEL
1500
DP1
The Gap, QLD 4061
W0.5
PV1 W0.5
ENTRY
9
T: 0451.511.884
200
900
PO Box 456
8
7
D.04
UNIT 2 DP1
LINE OF FENCE
R
OVE
1
ING
2055
SOFT LANDSCAPE
KITCHEN
BUILD
COURT YARD TD1
DIN
E OF
W0.1 W0.3
M. Pickard and D Perkins
LIVING
6
HILTON TERRACE
LIN
DP1 CO2
REFER TO DRAWING SK.202
27 Hilton Terrace
GARAGE DOOR
LDY
3390
CO2 TF1 D.05
LINE OF VEHICULAR GATE
LINE OF BUILDING OVER
STORE D.02
Tewantin
FFL: 2.700
CO3
CLIENT
DP1
N CO1 GARAGE
D0.7
QLD
FFL: 1.550
PR
5
DP1 FFL: 1.550 PR
CO1 GARAGE D0.7
Hilton Terrace
PROJECT NO.
CO2 D.02 FFL: 2.700
3390
D.05
STORE
PROJECT
GARAGE DOOR LDY TF1 LIVING
Duplex
21-018
CO2
D.03
DP1
R
DIN
OVE
4
KITCHEN
W0.1
ING
LINE OF FENCE
SOFT LANDSCAPE
DATE: 21,07,22
COURT YARD
UILD
2055
W0.3
OF B
DRAWN BY
TD1
LINE
ISSUE: E
3
UNIT 1
900
D.04
GF
DP1
2
ENTRY
200
1 PV1 W0.5 DP1 W0.5
1500
DP1
TD1
PROPERTY
POLE LINE OF SEWER
2
CLOTHES LINE CLEARANCE
PEDESTRIAN GATE W
3
4
SCALE: 1:100 m
ENTRY GATE
LETTERBOX & REFER TO DETAILS
Proposed
HOUSE NUMBER
Level 0 -
BINS SCREENING
REFER TO LANSCAPE
01 :: PROPOSED FLOOR PLAN REFER TO DETAILS
North
ARCHITECTURE PLANS FOR
DETAILS
- scale: 1=100
COLUMNS TO PERGOLA STRUCTURE/
SUPPORT TO UPPER LEVEL
CD 203
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 7
NOT FOR CONSTRUCTION
F G H I J
9650 3900 6000 2180 3106 6024
OPPERABLE SCREENS TO
BEDROOM BALCONY E
QUOD ARCHITECTURE PTY LTD
OUTDOOR SHOWER
1500
The Gap, QLD 4061
CENTRAL DP1
LINE OF ROOF OVER
COURT YARD 9
T: 0451.511.884
DP1
200
900
PO Box 456
8
UNIT 2 7
R
OVE
POOL PATIO 1
ING
2055
PV1 FFL: 1.950
BUILD
LINE OF ROOF OVER
PV1
POOL
OF
M. Pickard and D Perkins
6
LINE
FFL: 2.700
GAZEBO
REFER TO DRAWING SK.201
27 Hilton Terrace
LIVING TD1
FFL: 2.700
3390
Tewantin
CLIENT
QLD
DP1 DP1 S
5
DP1
DP1
Hilton Terrace
PROJECT NO.
3390
LIVING
PROJECT
Duplex
FFL: 2.700
21-018
LINE OF ROOF OVER
POOL
R
OVE
4
ING
FFL: 2.700
DATE: 21,07,22
UILD
POOL PATIO
2055
PV1 FFL: 1.950 GAZEBO
OF B
DRAWN BY
PV1 TD1
LINE
ISSUE: E
3
UNIT 1
900
DP1
GF
2
LINE OF ROOF OVER
200
DP1 1
1500
OUTDOOR SHOWER
W
CLEARANCE OVER
SEWER LINE SHOWN HATCHED
SCALE: 1:100 m
Proposed
Level 0 -
REFER TO LANSCAPE
01 :: PROPOSED FLOOR PLAN
South
ARCHITECTURE PLANS FOR
DETAILS
- scale: 1=100
CD 204
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 8
NOT FOR CONSTRUCTION
A B C D E F
6000 1500 6180 1534 2655 11630
E
PERGOLA STRUCTURE BELOW ROOF OVER LIVING AREA BELOW
QUOD ARCHITECTURE PTY LTD
DP1
below
1500
DP1 MS2
The Gap, QLD 4061
EAVES GUTTER below
9
T: 0451.511.884
LINE OF ROOF OVER
200
LINE OF ROOF OVER
900
PO Box 456
8 PRIVACY
W1.3 W1.4 DP
W1.5 DP W1.8 DP
SCREENING
7
LINE OF ROOF OVER
1 ENS 2
BALCONY SEAT
2055
W1.3 TL1 ENS 1
W1.6
D.02
M. Pickard and D Perkins
6 BED 3 TF1
HILTON TERRACE
W1.2 BED 4
TF1
WIR D0.6
REFER TO DRAWING SK.202
27 Hilton Terrace
ELEVATED DP DP
GARDEN BED
TF1 TF1
BED 2 UNIT 2
BALC
3390
W1.7 HIGH LEVEL
UP
WINDOW ABOVE
Tewantin
W1.1B TL1 D.01 D.01 BED 1
CLIENT
D.01
N BATH 1 D.02 UP
TF1 TF1
QLD
TF1 TL2
DP
5 DP
BATH 1 D.02 UP BED 1 BALC
W1.7 HIGH LEVEL
WINDOW ABOVE
TF1 TF1
D.01 D.01 D.01
Hilton Terrace
W1.1 TF1 TL2
PROJECT NO.
TL1
3390
UP
PROJECT
BED 2 UNIT 1
Duplex
21-018
TF1 WIR D0.6
DP DP
TF1
BED 4 TF1
BALCONY SEAT
4 BED 3 TF1
LINE OF ROOF OVER
ENS 1
DATE: 21,07,22
TL1
2055
W1.3 TL1 W1.6B
DRAWN BY
W1.2 ENS 2
ISSUE: E
3 DP W1.5 DP
W1.8 DP
W1.3 W1.4B
900
GF
LINE OF ROOF OVER
LINE OF ROOF OVER
2
200
1 EAVES GUTTER DP1 below MS2
1500
DP1
Below
LINE OF SEWER
CLEARANCE ZONE
OPERABLE SCREENS
2
W
Proposed Level
TO BEDROOM BALCONY
3
4
SCALE: 1:100 m
1 - North
01 :: PROPOSED FLOOR PLAN
- scale: 1=100
CD 205
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 9
NOT FOR CONSTRUCTION
F G H I J
9650 3900 6000 2180 3106 6024
OPPERABLE SCREENS TO
BEDROOM BALCONY E
QUOD ARCHITECTURE PTY LTD
LINE OF BUILDING UNDER
1500
DP1
The Gap, QLD 4061
EAVES GUTTER
EAVES GUTTER
9
T: 0451.511.884
200
900
PO Box 456
DP1 8
MS1
7
ROOF OVER GAZEBO
10° PITCH
2055
UNIT 2 MS1
M. Pickard and D Perkins
6
REFER TO DRAWING SK.201
27 Hilton Terrace
ROOF OVER GAZEBO
3390
20° PITCH
S
Tewantin
CLIENT
DP1
DP1 EAVES GUTTER
QLD
LINE OF BUILDING UNDER
5
LINE OF BUILDING UNDER
DP1
EAVES GUTTER DP1
Hilton Terrace
PROJECT NO.
3390
PROJECT
ROOF OVER GAZEBO
Duplex
21-018
20° PITCH
4
ROOF OVER GAZEBO
UNIT 1 10° PITCH
DATE: 21,07,22
2055
MS1
DRAWN BY
ISSUE: E
3
900
GF
DP1 2
EAVES GUTTER
200
DP1 1
EAVES GUTTER
1500
LINE OF BUILDING UNDER
CLEARANCE OVER
SEWER LINE
HATCHED
W
Level 1 / Roof
SCALE: 1:100 m
Proposed
- South
01 :: PROPOSED FLOOR PLAN
- scale: 1=100
CD 206
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 10
NOT FOR CONSTRUCTION
A B C D E F
6000 1500 6180 1534 2655 11630
E MS2
LINE OF BUILDING BELOW
ROOF OVER LIVING AREA BELOW
QUOD ARCHITECTURE PTY LTD
DP1
DP
1500
DP1
The Gap, QLD 4061
DP1
DP1
9 EAVES GUTTER
T: 0451.511.884
EAVES GUTTER
200
900
PO Box 456
8
7
EAVES GUTTER
EAVES GUTTER
LINE OF BUILDING BELOW LINE OF BUILDING BELOW
LINE OF BUILDING BELOW
1
2055
UNIT 2
M. Pickard and D Perkins
EAV
5° PITCH
6
ES G
HILTON TERRACE
MS1
UTTE
RAIN WATER
REFER TO DRAWING SK.202
27 Hilton Terrace
R
HEAD BELOW
3390
LINE OF BUILDING BELOW
BOX GUTTER
Tewantin
LINE OF BUILDING BELOW
CLIENT
DP1 MS1
QLD
N
EAVES GUTTER
5
DP1 15° PITCH 6° PITCH
BOX GUTTER
Hilton Terrace
MS1
PROJECT NO.
3390
MS1
PROJECT
LINE OF BUILDING BELOW
Duplex
5° PITCH
21-018
LINE OF BUILDING BELOW
MS1 MS1
R
UTTE
ES G
4
EAV
RAIN WATER
EAVES GUTTER
EAVES GUTTER
HEAD BELOW
UNIT 1
DATE: 21,07,22
2055
DRAWN BY
ISSUE: E
LINE OF BUILDING BELOW LINE OF BUILDING BELOW
3
900
GF
EAVES GUTTER DP#1
2
EAVES GUTTER
200
1 DP1
DP1
1500
DP
DP1
W
3
2
4
MS2
SCALE: 1:100 m
Roof - North
LINE OF SEWER
Proposed
CLEARANCE ZONE
01 :: PROPOSED FLOOR PLAN
- scale: 1=100
CD 207
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 11
NOT FOR CONSTRUCTION
90 89 265
Partition Setout 601 599
7500 2000 1500 0 10675 1581
439 820
Doors and Windows Setout 510 265
1840
2390 1140 8475
QUOD ARCHITECTURE PTY LTD
The Gap, QLD 4061
ENTRY
T: 0451.511.884
140
PO Box 456
1000
1000
UNIT 2
R
126
OVE
LINE OF BUILDING OVER
1 COURT
ING
KITCHEN
YARD
BUILD
2436
3000
E OF
M. Pickard and D Perkins
LIVING
290
LIN
REFER TO DRAWING SK.202
27 Hilton Terrace
90
LINE OF FENCE / VEHICULAR GATE
2800
LDY
410
LINE OF BUILDING OVER
Tewantin
CLIENT
820
GARAGE STORAGE PR
QLD
GARAGE STORAGE PR
Hilton Terrace
PROJECT NO.
LDY
PROJECT
LIVING
Duplex
21-018
LINE OF BUILDING OVER
COURT
DIN
R
KITCHEN
YARD
OVE
ING
DATE: 21,07,22
UILD
OF B
DRAWN BY
LINE
ISSUE: E
UNIT 1
GF
ENTRY
2
3
4
Dimensioned
SCALE: 1:100 m
Level 0 -
01 :: PROPOSED FLOOR PLAN
North
- scale: 1=100
CD 208
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 12
100 100
NOT FOR CONSTRUCTION
9650 3900 5810
1870 100 1870 100 1870 100
QUOD ARCHITECTURE PTY LTD
1552
The Gap, QLD 4061
CENTRAL
COURT YARD
200
T: 0451.511.884
PO Box 456
UNIT 2
2220
POOL PATIO 1
ON GROUND
LIVING POOL GAZEBO
M. Pickard and D Perkins
2000
REFER TO DRAWING SK.201
27 Hilton Terrace
898 200 941
Tewantin
CLIENT
QLD
950 200 898
Hilton Terrace
PROJECT NO.
PROJECT
Duplex
21-018
1237
LIVING
POOL GAZEBO
DATE: 21,07,22
POOL PATIO
ON GROUND
DRAWN BY
2400
ISSUE: E
UNIT 1
GF
200
1571
100 1920 100 1920 100 1920 100 1920
Dimensioned
SCALE: 1:100 m
9650 3900 8180 750 7718
Level 0 -
South
01 :: PROPOSED FLOOR PLAN
- scale: 1=100
CD 209
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 13
NOT FOR CONSTRUCTION
299
PARTITION SETOUT 55 90 90 90 90 90 90 90
835 4540 3610 2650 90 3400 3000 1639 3140 1283
90 90 90 90 90 90 90
90
600 4500 510 3010 90 2650 3180 900 2010 600 1039 3140 1580
BED 3 & 4 PARTITION SETOUT
55 90
WINDOW SETOUT
QUOD ARCHITECTURE PTY LTD
835 5240 3000 2650 900 2680 3000 760 900 3667
The Gap, QLD 4061
T: 0451.511.884
60
PO Box 456
290
1
90
ENS 2
2037
ENS 1
2600
COURT
3000
3000
YARD
M. Pickard and D Perkins
BED 3
90
BED 4
REFER TO DRAWING SK.202
27 Hilton Terrace
2037
90
90
WIR
BED 2 UNIT 2
BALC
UP
2165
2165
Tewantin
90
BED 1
CLIENT
1000
BATH 1 UP
QLD
200
200
200
BATH 1 UP BED 1 BALC
Hilton Terrace
2165
PROJECT NO.
90
90
600
1000
UP
3267
PROJECT
BED 2 UNIT 1
Duplex
21-018
877
WIR
90
1277
BED 4
800
4165
BED 3
90
90
COURT
3000
ENS 1
YARD
DATE: 21,07,22
1900
1900
1800
ENS 2
DRAWN BY
ISSUE: E
90
90
90
90
GF
BED 1 & 2 WINDOW SET OUT
BED 3 & 4 WINDOW SET OUT
BED 2 PARTITION SET OUT
BED1 PARTITION SET OUT
Dimensioned Level
2
3
4
SCALE: 1:100 m
1- North
CD 210
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 14
NOT FOR CONSTRUCTION
706 8368 2050 12229 1686
407 8666 2050 614 11615 290
QUOD ARCHITECTURE PTY LTD
The Gap, QLD 4061
T: 0451.511.884
PO Box 456
600
600
LINE OF BUILDING BELOW LINE OF BUILDING BELOW
EAVES GUTTER
LINE OF BUILDING BELOW
M. Pickard and D Perkins
EAV
ES G
HILTON TERRACE
5447
UTTE
REFER TO DRAWING SK.202
27 Hilton Terrace
R
LINE OF BUILDING BELOW
BOX GUTTER
Tewantin
LINE OF BUILDING BELOW
CLIENT
QLD
10893
10890
12090
BOX GUTTER
Hilton Terrace
PROJECT NO.
PROJECT
LINE OF BUILDING BELOW
Duplex
21-018
5447
LINE OF BUILDING BELOW
R
UTTE
ES G
EAV
EAVES GUTTER
DATE: 21,07,22
DRAWN BY
ISSUE: E
LINE OF BUILDING BELOW LINE OF BUILDING BELOW
600
600
GF
Dimensioned
SCALE: 1:100 m
Roof - North
01 :: PROPOSED FLOOR PLAN
- scale: 1=100
CD 211
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
Page 15
NOT FOR CONSTRUCTION
6020
QUOD ARCHITECTURE PTY LTD
LINE OF BUILDING UNDER
The Gap, QLD 4061
EAVES GUTTER
T: 0451.511.884
PO Box 456
3728
M. Pickard and D Perkins
REFER TO DRAWING SK.201
27 Hilton Terrace
1953
Tewantin
CLIENT
EAVES GUTTER
QLD
LINE OF BUILDING UNDER
LINE OF BUILDING UNDER
EAVES GUTTER
Hilton Terrace
PROJECT NO.
1893
PROJECT
Duplex
21-018
DATE: 21,07,22
3771
DRAWN BY
ISSUE: E
GF
EAVES GUTTER
LINE OF BUILDING UNDER
8180
Dimensioned
SCALE: 1:100 m
Roof South
01 :: PROPOSED FLOOR PLAN
- scale: 1=100
CD 212
THIS DRAWING IS COPYRIGHT AND PROPERTY OF THE AUTHOR AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF THE AUTHOR. LARGE SCALE DRAWINGS AND WRITTEN DIMENSIONS TAKE PREFERENCE. DO NOT SCALE OF DRAWINGS ALL DIMENSIONS TO BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF WORK. ALL DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE AUTHOR.
The text continues on page 16.
Used in these records
21-018 Hiilton CD [E] For OP works.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.