Council archive · source document
Complied Approved Plan - Negotiated - MCU22 0145 & OPW22 0212 · MCU22/0145
Plans and drawings: the text below has words only, no drawings.
Very large file (11.2 MB): may take a few minutes to open.
Original PDF page 22, section 1. The text section number identifies this passage in the reader.
LEGEND - PROPOSED:
ROAD CENTRELINE
DRIVEWAY OUTLINE
22.80 FINISHED CONTOURS
B99 Vert Clearance (2004) F.L.22.90 FINISHED SURFACE LEVEL
I.P.12.257, 36.500
/
41.4
FL22.80
F.L.40.80 FILL GRADE LINE AND LEVEL
300
41.2
GROUND FLOOR FFL39.50
.0
RETAINING WALL
/
BDY
41
8
40.
F.L.40.80
F.L.41.08 N
6
40.
BUILDING OUTLINE - SLAB ON GROUND
2700
/
4
F.L.39.50
40.
F.L.40.10
STORMWATER DRAINAGE LINE
2
40.
BASEMENT FFL36.50
ROOFWATER DRAINAGE LINE
B85 Ground Clearance (2004)
/
6.887, 37.220
8.387, 37.145
F.L.40.10 /
3.500, 36.881
1.500, 36.831
11.507, 36.625
12.257, 36.531
13.007, 36.500
13.387, 36.500
GRATED DRAIN F.L.39.50
0
40.
/
/
CROSSOVER /
PROPOSED SEWER F.L.41.31 F.L.39.50
/
/
RE-ALIGNMENT
8
39.
/
VC 1.5
02864
43109.
EXISTING TELECOMMUNICATIONS EXISTING 150Ø
R9
41.4
/
VC LENGTH OPTICAL FIBRE TO BE RELOCATED SEWER MAIN
RADIUS
GRADE 12.500% 2.500% 10.000% -5.000% -16.670% 0.000%
6
41.6
/
39.
DATUM RL 29.0 F.L.39.50
36.764
41.8/
GROUND FLOOR FFL39.50 F.L.38.28
LIP LEVELS LHS F.L.41.67 BASEMENT FFL36.50
F.L.39.50
F.L.37.75
F.L.38.50 31.4
46
36.524
MATCHES EXISTING
LIP LEVELS RHS VERGE CROSSFALL
9
F.L.37.60 F.L.37.40
.23
24
S
28.9
0.261
74
0.000
2.160
2.954
3.502
0.693
0.777
1.235
CUT/FILL F.L.39.50 F.L.38.33 -26
.4 .6%
38
F.L.41.33
41 MATCH NEATLY TO
.4
(Depth of) EXISTING PATH
F.L.38.50
F.L.38.40 F.L.36.03 26.
36.531
36.881
37.220
37.145
36.644
36.500
36.500
44
36.831
.2 3
DESIGN 41 F.L.36.15
LEVELS F.L.36.50 F.L.37.60 F.L.35.97
4
37.0
2
36.8
36.6
36.4
37.
3S7.
F.L.37.72
36.2
-3.
.0
38.691
41
37.997
38.380
9
37.574
36.644
39.454
40.002
37.092
EXISTING SURFACE F.L.38.50 -19 %
.2%
LEVELS DRIVEWAY CONTROL LINE DW01
.8
36
F.L.37.00
40
.8604242806
.4
336776.
12.257
6.887
8.387
3.500
F.L.40.70
20.000
24.239
0.000
1.500
F.L.37.05
.6
40
.6
36
CHAINAGE F.L.36.50
36
.4
.6
S
.8
40
36
-2
.2
F.L.39.10 .0
37
40
.0%
.0 389
HC DATA 40 .42860 F.L.38.03 37.2 F.L.36.75 -1
0 .5%
.8
39 16
.42
DRIVEWAY - DW01
37.2
F.L.39.50 2
.6
39
F.L.37.31
39
.2
HOR. 1 : 100 F.L.37.38 F.L.36.71
F.L.39.10
VERT. 1 : 100
37.0
F.L.39.50 -2.
0% F.L.36.52
F.L.39.20 F.L.37.02
S
12
.41
37.
36.8
8
2
F.L.38.50
39.
00
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Complied Approved Plan - Negotiated - MCU22 0145 & OPW22 0212.pdfRelated documentApplication case desk ↗
About this file
- File size
- 11.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.