Original source · versioned page text
Architecturals - REV C
Original PDF page 10, section 1. The text section number identifies this passage in the reader.
LEGEND - INTERNAL
AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD
C'BD - CUPBOARD
DP - DOWNPIPE
DW - DISHWASHER PROV.
75 25 FW - FLOOR WASTE
GAS - GAS CONNECTION
HP - HOT PLATE
HWS - HOT WATER SYSTEM
L - LINEN
MH - MANHOLE
SARKING TO WALLS AS 190x190 LAMINATED HWD POST MW - MICROWAVE PROV.
TIMBER FRAME R1.0 SARKING TO WALLS OHC - OVERHEAD CUPBOARD
PER SPECIFICATION FRAME PTY - PANTRY
AS SPEC WALL INSULATION AS PER GAL STIRRUP R - ROBE
HEBEL AS SPEC
BUILDING SPECIFICATION TO TO CONCRETE FOOTING. REF - REFRIDGERATOR SPACE
POWERWALL LINE OF FRAME 2/M12 BOLTS TO POST RH - RANGEHOOD
SYSTEM TERMITE PROTECTION WALLS TO ACHIEVE R1.5 RATING TERMITE DOOR TRACK FFL SH - SHELF
AS PER SPEC. PROTECTION
TR - TOWEL RAIL
70 min
20-25mm BATTENS CLADDING AS PER SPECIFICATION TRH - TOILET ROLL HOLDER
AS PER SPEC. UBO - UNDER-BENCH OVEN
310
INSTALLED IN ACCORDANCE WITH WO - WALL OVEN
DPC MANUFACTURERS SPEC.
45
LEGEND - EXTERNAL
45
45
50
GL
CONCRETER TO ENSURE 100 CONCRETER TO ENSURE
BV - BRICK VENEER
NEAT FINISH TO SLAB EDGE CONC. PATIO SLAB BL - BLOCKWORK
NEAT FINISH TO SLAB EDGE WHERE APPLICABLE CO - CUSTOM ORB SHEETING
SAND FILL FC - FIBRE CEMENT SHEETING
HF - HARDIFLEX CLADDING
WAFFLE-POD APPROVED LB - LINEA-BOARD CLADDING
WAFFLE-POD SLAB SYSTEM TO ENG. RBB - RENDERED BLUEBOARD
SLAB SYSTEM TO ENG. TERMITE BARRIER FIBRE CEMENT OPTIONAL CONCRETE
DESIGN & SPECIFICATIONS RB - RENDERED BRICKWORK
DESIGN & SPECIFICATIONS PACKERS PATIO SLAB RBL - RENDERED BLOCKWORK
CONCRETE SM - SYCON MATRIX PANELING
SLAB TB - TIMBER BATTENS
CONCRETE FOOTING TO WB - WEATHERBOARD (AS SPEC)
ENGINEERS DETAIL
A - HEBEL SLAB DETAIL B - CLADDING SLAB EDGE C - CLADDING - DOOR SILL D - POST - 190x190 SECTION
1 : 10 1 : 10 1 : 10 1 : 20
25 75
HEBEL PIER
BATTEN CAVITY
FRAME
OVERHEAD CUPBOARDS AS
PER CABINET MAKER DESIGN
70mm TIMBER FRAME
75 25 90 25 75
HEBEL POWERPANEL WALL CLADDING
290
20-25mm NO GROUT UNDER ARCHITRAVE
290 SHOWER SCREEN FIXED GLASS WINDOW AS PER PLAN
SHOWER SCREEN REVISIONS
75 25 90 25 75 AS PER SPEC. FALL TO WASTE # DATE DETAILS
A 04-03-20 WD FIRST ISSUE
B 18-03-20 REVISIONS
20x20 ALUMINUM ANGLE FLOOR
BENCH TOP CUT C 25-03-20 REVISIONS
WASTE
FRAME IN TO FRAME
HEBEL
50
FIXING BATTEN TILERS BEDDING
MAIN SLAB LEVEL
SLAB COMPOUND CUPBOARDS AS PER CABINET
30 MIN
MAKER DESIGN
30 45
WATERPROOF MEMBRANE
75
EXTERNAL SLAB LEVEL IN ACCORDANCE WITH
BCA 3.8.1 REQUIREMENTS
APPROVED TERMITE BARRIER po box 418 p (07) 5442 6413
TO PERIMETER OF BUILDING AND TO cooroy q 4563 f (07) 5442 6549
ALL SLAB PENETRATIONS. INSTALL IN QBSA 1083000
ACCORDANCE WITH MANUFACTURERS
SPECIFICATIONS AND AS3660
F - REBATED SHOWER G - KIT SPLASHBACK WINDOW
This plan remains copyright to
Ausmar Group and may not be
used in part or in whole without
the written consent of the
GROUND LEVEL
1 : 10 author. © 2015 Ausmar Group
1 : 20 WRITTEN DIMENSIONS TO
TAKE PRECEDENCE OVER SCALE
DETAILS
PROJECT DESCRIPTION:
Proposed Display For:
E - HEBEL - COLUMN CLIENT:
BRENDAN AND JESS
BEDFORD
1 : 10
SITE ADDRESS:
LOT 3, 5 FIGBIRD CT
LAKE MACDONALD
UBD REF
DRAWN BY S HOSKINS
SCALE JOB CODE
As indicated
ON A2
DATE
04-03-20
D-BJB2
SHEET 9 OF 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.