Officer: 	Mark Lewis
Direct Telephone: 	07 53296290
Our Reference:	MCU23/0134 & OPW23/0159
Your Reference:	9 Wyuna Dr.
25 October 2023
NN Bakaric
C/- The Jetty Specialist
18 Ron Parkinson Cres
CORBOULD PARK   QLD  4551
[email protected]
Dear Sir
Information Request
Planning Act 2016
I refer to your application and advise that Council requires further information to satisfactorily assess the proposal.
application details
Application No.	MCU23/0134 & OPW23/0159
Street Address:	9 Wyuna Dr Noosaville Qld 4566
Real Property Description:	Lot 4 N 10575
Planning Scheme:	Noosa Plan 2020 (25 September 2020)
INFORMATION REQUIRED
The information requested is set out below:
Issue
The available aerial photos indicate vegetation within the waterway in the frontage of the site but the vegetation is not shown on the submitted plans.
Information Required
Indicate on the plans any existing vegetation (species, size, location) within the waterway in the frontage of the site.
Provide additional detail on how any existing vegetation is to be protected during the construction works.
Provide sufficient detail to demonstrate how the proposed works achieve compliance with The Waterways Works Code – Performance Outcome PO1(a, b & c)
Issue
The pontoon is proposed to be setback 1.5m from the prolongation of the property boundary. The proposed setback is less than that described in The Waterways Works Code – Acceptable Outcome AO9.1.
The subject site has water frontage greater than 15 metres in width and therefore is required to be setback a minimum of 3 metres from the prolongation of the boundaries as per Acceptable outcome AO9.1 of the Waterways Works Code. The plans provided show the pontoon within 1.5 metres of the site boundary and therefore does not comply with the Acceptable outcome.
AO9.1 For lots with waterway frontage greater than 15 metres in width, jetties and pontoons are setback a minimum of 3 metres from the prolongation of the boundaries (Refer Figure 9.4.9.3A).
Information Required
Provide amended plans that are in accordance with The Waterways Works Code – Acceptable Outcome AO9.1 and indicate a 3 metre setback from the prolongation of the boundary.
due date for response to information request
The due date for providing the requested information is 2 February 2024. Email your response to [email protected]. Please advise Council of your response to this information request in accordance with section 13 of the Development Assessment Rules.
If you do not provide a response before the due date, it will be taken as if you have decided not to respond to the information request and Council will continue with the assessment of your application.
other details
You can follow the progress of this application online at www.noosa.qld.gov.au. The “Online Services” page can be accessed via "Quick Links" on the left hand side of the screen.
Should you have any further queries in relation to the above, please do not hesitate to contact me on the number above.
Yours faithfully,

Mark Lewis
Coordinator Engineering

[word/footer2.xml]
Page 2 of 2

[word/footer3.xml]
ABN 97.969.214.121	PO Box 141
			noosa.qld.gov.au	Tewantin QLD 4565
			[email protected]	07 5329 6500
				Page 1 of 2

[word/header1.xml]
3

Used in these records

About this file

File size
50 KB (small file)
File type
DOCX

No other editions are linked here.

Original file

Log in to download the original file

Information Request MCU23 0134.docx · 50 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.