Original source · versioned page text
Planning Report
Specific Outcomes Probable Solutions Comment
skyline;
AND
O89 Any premises adjacent to land in Not applicable
a residential zone has— The proposed development area
a) a building scale that does not does not adjoin land in a residential
dominate the residential premises or zone.
the residential character of the
streetscape; and
b) landscaped setbacks consistent with
that required for the residential zone.
Comment: The proposal demonstrates compliance with the Noosa Heads Locality Code, with the
exception of outcomes O7, O80 and O81 in relation to height and use within the Community Services
Zoned part of the site. Where probable solutions are not met compliance with the specific outcome
has been demonstrated. Town planning grounds to justify the use, despite the conflict with O7, O80
and O81 are provided above and in sections 7.7 and 7.8 of the Town Planning Report.
BUSINESS USES CODE
Specific Outcomes Probable Solutions Comment
TABLE 14.8 FOR ALL BUSINESS USES
14.15 Effects of Use
Electricity infrastructure
O18 The development does not S18.1 No solution provided Complies
adversely impact on existing or The proposal will not impact on
future electricity supply electricity supply or infrastructure.
infrastructure;
AND
O19 All uses and works maintain an S19.1 Development for uses Not applicable
adequate safe distance from adjacent to or within 50m of an The proposal is not in proximity to
electrical infrastructure including existing electricity substation an electricity substation.
substations, overhead powerlines, incorporates noise attenuation
power poles and transformers. measures to mitigate noise impacts;
AND
S19.2 Buildings and structures Complies
(including swimming pools, sheds, Proposed buildings are clear of
tennis courts and outbuildings) are overhead power lines and electricity
not constructed under overhead easements.
electricity transmission lines, or
within electricity easements.
N oise
O20 Development is designed and No solution provided Complies
sited to avoid noise emissions that The proposal will not generate noise
unreasonably diminish the amenity emissions that will unreasonably
of the area or surrounding uses. diminish the amenity of the area or
surrounding uses. Refer to the
accompanying Acoustic Report.
M echanical plant and
equipm ent and storage areas S21.1 Mechanical plant and Complies
O21 Mechanical plant and equipment are— Mechanical plant and equipment will
equipment (including air a) located more than 2m from be appropriately screened by
conditioning equipment) and any property boundary; fencing, landscaping or behind the
storage areas are designed and b) where located at ground level, curtilage of the building.
located to— screened by fencing 1.5m in
a) avoid adverse visual impacts height or dense vegetation of at
when viewed from the street and least 1.5m in width incorporating
adjoining properties; and grouped trees and shrubs with
b) visually integrate with the maximum separation distance of
building design. 1m measured from the centre of
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.