Council archive · source document
001A5368.001
Text sections not matched to the original PDF pages. See original document to check page numbers.
83. The developer must provide waste storage and disposal facilities in accordance with
Planning Scheme Policy “Waste Management Multi-Dwellings and Commercial and Industrial
Premises”, including an external imperviously paved area correctly sized for all refuse and
recycling containers and suitably screened from public places and neighbouring properties.
84. The developer must ensure there is a safe and suitable kerbside bin pick up location, or must
provide a safe and suitable onsite collection. NB the refuse vehicle must be able to enter and
leave the site in a forward direction without any dangerous maneuvers.
85. A bin wash area is required with a cold-water tap, hose and drain outlet connected to sewer,
via a bucket trap. The drain outlet is to be designed to prevent storm water entry to the
sewerage system and this can be achieved with a nib wall 50mm high and up to 700mm x
700mm wide (max 0.5m²), or alternatively the waste area can be roofed, or any other design
approved by Council.
86. Noise emission from mechanical equipment (air conditioners, refrigeration equipment or pool
pumps etc) shall comply with the following requirements:
a. The equipment shall be installed and located in a manner that prevents excessive noise
in accordance with Council’s Local Law No. 12 - Control of Nuisances. Infringement
Notices (on-the-spot fines) may apply for offences.
b. A person must not use equipment on any day if it makes or causes noise to be made:
i. From 10pm to 7am: More than the lower of either –
40 dB(A)
3 dB(A) above the background noise level
ii. From 7am to 7pm: More than the lower of either –
50 dB(A)
5 dB(A) above the background noise level
iii. From 7pm to 10pm: More than 3 dB(A) above the background noise level.
iv. Pool pumps must not be audible at an effected premises between 10pm-7am
c. Submission of written certification from a suitably qualified person confirming that the
noise levels comply when measured at either the residential boundary or outside the
most exposed part of an affected building, whichever is the closest to the equipment.
This is required immediately after installation of the equipment and prior to any
occupation of the building, and in a format approved by Council. This assessment must
take into account noise from all fixed equipment on the property e.g. swimming pool
pump, heating equipment, that may increase the overall noise level emitted.
Note: it is recommended that the consultant that will be engaged to certify the noise levels of
mechanical equipment is asked to comment on the position and installation of equipment at
the plan design stage, this way noise problems can be minimised or avoided cost effectively.
87. Noise from residential building works shall comply with the following –
a. Limited to between 7:00am to 6:00pm Monday to Saturday.
b. All reasonable measures are taken to minimise noise emissions.
c. Not permitted on Sunday or public holidays.
5 REFERRAL AGENCY CONDITIONS
Not Applicable.
Page 11 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
001A5368.001.pdfRelated documentPublic source context ↗
07/2555 Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 88 KB (small file)
- File type
No other editions are linked here.