BUSHFIRE PRONE AREA - MEDIUM CATEGORY

THIS PROPOSED DWELLING IS LOCATED IN A MEDIUM CATEGORY AND CONSTRUCTION IS TO COMPLY WITH
AS 3959 1999 WHICH REQUIRES LEVEL 1 CONSTRUCTION - please refer to AS 3959 1999.

 

The requirements shall be one or a combination of the following:

ean mre ee

a Non-combustible

b Fire retardant-treated timber for a minimum of 400mm above the finished ground level.

c Timber mounted on galvinised metal shoes with a clearance of not less than 75mm above the adjacent finished ground level or paving level

The above do not apply where the subfloor space is totally enclosed, |
WINDOWS {:
All openable windows, including louvres, shall be screened with corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of i
1.8mm in such a way that the entire opening remains screened when the window is open: 1
EXTERNAL DOORS

Extemat doors shall be fitted with weather strips or draught excluders to prevent the penetration of build-up of buming debris beneath the door and tight hi
fitting door screens fitted with corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm. :
VENTS AND WEEPHOLES ‘
Vents and weephotes shall be protected with spark guards made from corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of ie
1.8mm.

ROOFS

All roof sheeting shall be non-combustible and sarked (with a flammal

 

index of not more than 5) and rooflight gazing shall be of wired glass

 
 

 

             

 

 

Thermoplastic material or toughened glass shall not be used as the glazing for rooflights.
All gaps under the corrugations or ribs of the roofing material where it meets the fascia or wall line shall be sealed or protected by fully sarking the roof or by
providing corrosion-resistant steel or bronze mesh, with a maximum aperture size of 1.8mm, profiled metal sheet, neoprene seal, compressed mineral wool
or similar material. . !
VES and FASCIAS .
All eaves shall be enclosed and the fascia or the gaps between the rafters sealed. . . . soem ste kee we
. ‘
Gi RS and Di IPES Ss '
Any materials or devices used to stop leaves collecting in the gutters shall have a flammability index of not greater than 5 when tested in accordance with AS es of 2,
1530.2. g |
SERVICE PIPES (WATER and GAS)
All exposed piping for water and gas supplies shall be metat.
Pipes of other materials shall be buried to a depth of at least 300mm below the finished ground level.
: 3
of,
eH
e ORIVEWAY BY OWNER TO
COMPLY WITH COUNCIL
DESIGN IN ACCORDANCE WITH THE QUEENSLAND HOME REQUIREMENTS
BUILDING CODE, AS 1684.2 N3 CLASSIFICATION, BUILDING
CODE OF AUSTRALIA AND THE STANDARD BUILDING BY-LAWS.
Se = %, 250mm MAX HEIGHT OF BATTER
"PAD LEVEL Se ITHIN 1500mm OF BOUNDARY
GENERAL NOTES RL 165.80 —S "
1 ALL MATERIALS SHALL BE NEW. SPY
2 Foornes 10 ENGINEER DETALS. Rea
‘OOTIN' 'O HAVE SOLID BOTTOMS » <2 oS
[ANO EVEN BEARING THROUGHOUT. SSNS
3 SLAB: TO ENGINEER DETAILS — oN
UNDERLAY WITH 200mm POLYTHENE 4
WATERPROOF MEMBRANE AND ALL
PROTRUSIONS, CAST ON S0mm SAND
BEDDING ON APPROVED FILL.
CONCRETE STRENGTH TO BE 20MPa
AT 28 FAYS, USE TERMITE CONTROL
AS PER BUILDERS SPECIFICATIONS.
4 TIMBER FRAMING: ALL FIXINGS AS
PER CONNECTION DETAILS AND GOOD
WORKMANSHIP,
$ LININGS: AS PER BUILDERS SPECIFICATIONS,
& ROOFING: COLORBOND METAL SHEET
ROOFING OR CONCRETE ROOF TILES

OVER AN APPROVED SARKING MATERIAL
AND FIXED IN ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS.

2 PLUMBER AND DRAINER; TO LOCAL
AUTHORITY REGULATIONS.

& ELECTRICIAN: TO LOCAL ALITHORITY
REGULATIONS.

a BRICKLAYER: GALVINISED WALL TIES
1 ROW AT 2 COURSES ABOVE FLASHING
LINE AND 1 ROW IN THE SECOND LAST
BED JOINT FROM TOP OF WALL AND @
SO0crs. IN BETWEEN ON EACH STUD.
PROVIDE WEEP HOLES @ 900crs. ALONG
FLASHING,

10. ALL WET AREA FLOOR AND SHOWER FLOORS.
TO COMPLY WITH B.C.A. SECTION 3.8,1,

NOTE: BUILDER TO CHECK AND CONFIRM ALL
MEASUREMENTS PRIOR TO COMMENCEMENT
OF CONSTRUCTION. DO NOT SCALE DRAWINGS,
WRITTEN OIMENSIONS TAKE PRECEDENCE AT
ALL TIMES” STORMWATER THROUGH PV.C.
PIPE TO LOCAL COUNCIL REGULATIONS.

 

 

LEGEND - INTERNAL

AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD
CBD - CUPBOARD

OP - DOWNPIPE

OW - DISHWASHER PROV.
FW - FLOOR WASTE

GAS - GAS CONNECTION

HP - HOT PLATE

HWS - HOT WATER SYSTEM
L- LINEN

MH - MANHOLE.

MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
PTY - PANTRY

R-ROBE

REF - REFRIDGERATOR SPACE
RH - RANGEHOOD

SH - SHELF

TR - TOWEL RAIL

TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
‘WO - WALL OVEN

S/R - SMART ROBE.

 

 

EGEND - EXTERNAL

BV - BRICK VENEER

BL - BLOCKWORK

CO - CUSTOM ORB SHEETING

FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL, PANELS
LB-LINEA-BOARD CLADDING |
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SM - SYCON MATRIX PANELING
78 - TIMBER BATTENS

WB - WEATHERBOARD (AS SPEC)

PROPERTY
DESCRIPTION

LOT 23. _ SP 199350
PARISH: TUCHEKOI ~ °

 

 

 

COUNTY: MARCH
AREA: 3.511Ha
REVISIONS

 

#| DATE OETAILS

Rt] 25/0209] CLIENT CHANGES:
IR2|06-04-09| CLIENT CHANGES.
R3} 20-04-09] CLIENT CHANGES:

FR] 30-04-09} WORKING DRAWINGS
Rs]

6

 

 

 

 

 

06-05-09] CLIENT CHANGES
'28-08-09| INFO ADDED

 

 

 

 

 

 

 

NY

i

po box 418 p (07) 5442 6413
cooray 9 4563 f (07) 5442 6549
BSA 1083000

 

This plan remains copyright to

‘Ausmar Homes and may not be

used in part or in whole without

tha writtan consent of the author.
© 2008 Ausmar Homes

 

WRITTEN DIMENSIONS TO
-| TAKE PRECEDENCE OVER SCALE

 

SITE PLAN

 

PROJECT DESCRIPTION:
Proposed Residence For.

 

 

 

 

 

 

CLIENT:
HENRY ALEXANDER
CURREN
SITE ADDRESS:
326 LAWNVILLE ROAD
COOROY
UBD REF

ORAWN BY =B TOVEY
SCALE JOB CODE
4:1500
ote | HAC
26-08-09

 

 

 

 

 

 

SHEET | OF 11

 

 

 

 

 

Used in these records

About this file

File size
3.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1530 - MCU - Detached House [As Published].pdf · 3.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.