09/1530 - MCU - Detached House [As Published] · 132009.1530

of 34

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

 

 

 

BUSHFIRE PRONE AREA - MEDIUM CATEGORY

THIS PROPOSED DWELLING IS LOCATED IN A MEDIUM CATEGORY AND CONSTRUCTION IS TO COMPLY WITH
AS 3959 1999 WHICH REQUIRES LEVEL 1 CONSTRUCTION - please refer to AS 3959 1999.

SUPPORTING POSTS, COLUMNS, STUMPS PIERS AND POLES
The requirements shall be one or a combination of the following:

a Non-combustible

b Fire retardant-treated timber for a minimum of 400mm above the finished ground jevel.

c Timber mounted on-galvinised metal shoes with a clearance of not less than 75mm above the adjacent finished ground level or paving fevel
The above do not apply where the subfloor space is totally enclosed.

WINDOWS
Ail openable windows, including louvres, shall be screened with corrosion-resistant stee!, bronze or aluminium mesh with a maximum aperture size of
1.8mm in such a'way that the entire opening remains screened when the window is open. .

EXTERNAL DOORS .
External doors shall be fitted with weather strips or draught excluders to prevent the penetration of build-up of burning debris beneath the door and light
fitting door screens fitted with corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm.

 

NTS AND WEEPHOLES

Vents and weepholes shall be protected with spark guards made from corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of
1.8mm.

ROOFS

All roof sheeting shall be non-combustible and sarked (with a flammability index of not more than 5) and fooflight glazing shall be of wired glass.
Thermoplastic material or toughened glass shall not be used as the glazing for tooflights.

All gaps under the corrugations or ribs of the roofing material where it meets the fascia or wal shall be sealed or protected by fully sarking the roof or by
providing corrosion-resistant ste! or bronze mesh, with a maximum aperture size of 1.8mm, profiled metal sheet, neoprene seal, compressed mineral wool
or similar material.

 

 

 

EAVES and FASCIAS
Al eaves shall be enclosed and the fascia or the gaps between the rafters sealed. - oe os

GUTTERS and DOWNPIPES

Any materials or devices used to stop leaves collecting in the gutters shall have a flammability index of not greater than 5 when tested in accordance with AS
1530.2. ©

SERVICE PIPES (WATER and GAS)

All exposed piping for water and gas supplies shall be metal.
Pipes of other materials shall be buried to a depth of at least 300mm below the finished ground level,

DESIGN IN ACCORDANCE WITH THE QUEENSLAND HOME
BUILDING CODE, AS 1684.2 N3 CLASSIFICATION, BUILDING
CODE OF AUSTRALIA AND THE STANDARD BUILDING BY-LAWS.
3%,
Oo

GENERAL NOTES ‘CGA
%

LZ
2 FOOTING: TO ENGINEER DETALS. yy
R
Y

3 ‘SLAB: TO ENGINEER DETAILS
UNDERLAY WITH 200mm POLYTHENE SS
WATERPROOF MEMBRANE AND ALL
PROTRUSIONS, CAST ON 50mm SAND
BEDDING ON APPROVED FILL.

CONCRETE STRENGTH TO BE 20MPa
- AT 28 FAYS. USE TERMITE CONTROL
AS PER BUILDERS SPECIFICATIONS.

4 TIMBER FRAMING: ALL FIXINGS AS

PER CONNECTION DETAILS AND GOOO.

WORKMANSHIP.

LININGS: AS PER BUILDERS SPECIFICATIONS,

ROOFING: COLORBOND METAL SHEET

ROOFING OR CONCRETE ROOF TILES

‘OVER AN APPROVED SARKING MATERIAL

AND FIXED IN ACCORDANCE WITH THE

MANUFACTURERS SPECIFICATIONS.

7 PLUMBER AND DRAINER: TO LOCAL
AUTHORITY REGULATIONS.

& ELECTRICIAN: TO LOCAL AUTHORITY
REGULATIONS,

9. BRICKLAYER: GALVINISED WALL TES:

1 ROW AT 2 COURSES ABOVE FLASHING
LINE AND 1 ROW IN THE SECOND LAST :
BEO JOINT FROM TOP OF WALL AND @
‘SQ0crs, IN BETWEEN ON EACH STUD.
PROVIDE WEEP HOLES @ 900crs. ALONG
FLASHING.
10. ALL WET AREA FLOOR AND SHOWER FLOORS:
TO COMPLY WITH B.C.A. SECTION 3.8.1.

2
FOOTINGS TO HAVE SOLID BOTTOMS
ANO EVEN BEARING THROUGHOUT. ri

STs

 

ae

NOTE: BUILDER TO CHECK AND CONFIRM ALL
MEASUREMENTS PRIOR TO COMMENCEMENT
GF CONSTRUCTION. DO NOT SCALE DRAWINGS,
WRITTEN DIMENSIONS TAKE PRECEDENCE AT
“ALL TIMES “STORMWATER THROUGH P-.V.C-
PIPE TO LOCAL COUNCIL REGULATIONS.

 

  

 

DRIVEWAY BY OWNER TO.
COMPLY WITH COUNCIL
REQUIREMENTS

250mm MAX HEIGHT OF BATTER
WITHIN 1500mm OF BOUNDARY

 

 

LEGEND - INTERNAI
AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD
C’8D - CUPBOARD

OP - COWNPIPE

OW - DISHWASHER PROV.
FW - FLOOR WASTE

GAS - GAS CONNECTION’
HP - HOT PLATE

HWS - HOT WATER SYSTEM
L-LINEN

MH - MANHOLE

MW - MICROWAVE PROV,
OKC - OVERHEAD CUPBOARD.
PTY - PANTRY *

R- ROBE

REF - REFRIOGERATOR SPACE
RH - RANGEHOOD

SH - SHELF

TR - TOWEL RAIL

TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
‘WO - WALL OVEN

S/R - SMART ROBE.

 

LEGEND - EXTERNAL

BV - BRICK VENEER

BL - BLOCKWORK

CO - CUSTOM ORB SHEETING
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
LB - LINEA-BOARD CLADDING
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
RBt - RENDERED BLOCKWORK
SM - SYCON MATRIX PANELING
TB - TIMBER BATTENS

WB - WEATHERBOARD (AS SPEC)

 

 

PROPERTY
DESCRIPTION

LOT. 23. SP 199350
PARISH: TUCHEKO| ““~

 

COUNTY: MARCH
AREA: 3.511Ha
REVISIONS
#{ DATE DETAILS

 

 

4] 25/02/08 | CLIENT CHANGES

 

FR2)}06-04-09| CLIENT CHANGES

 

3} 20-04-09 | CLIENT CHANGES

 

R4) 30-04-09] WORKING DRAWINGS|

 

IRS] 06-05-09 | CLIENT CHANGES

 

6 [26-06-08| INFO ADDED

 

 

 

 

 

 

po box 418 Pp (07) 5442 6413
corey q 4563 (07) 5442 6549
QBSA 1083000

 

This plan remains copyright to

Ausmar Homes and may not be.

used in part or in whole without

the writtan consent of the author,
© 2008 Ausmar Homes

 

WRITTEN DIMENSIONS TO
TAKE PRECEDENCE OVER SCALE

 

SITE PLAN

7

 

PROJECT DESCRIPTION:
Proposed Residence For:

 

CLIENT:
HENRY ALEXANDER
CURREN

 

SITE ADDRESS:
326 LAWNVILLE ROAD

COOROY

 

UBD REF

 

ORAWNBY BTOVEY

 

SCALE- —
12 1500 408 CODE

CATE HAC

26-08-09

 

 

 

SHEET 1] OF TH

 

 

 

 

Used in these records

About this file

File size
3.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1530 - MCU - Detached House [As Published].pdf · 3.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.