6 5 4 3 2 1
REVISION HISTORY
ISSUE FOR APPROVAL APPROVED.................
REV DESCRIPTION BY DATE CHECKED BY
NOT FOR CONSTRUCTION 1 INITIAL RELEASE P.Z. 20/03/2018
NAME................................
ACCESS MANHOLE SIGNED.............................
900 x 900
D DATE........../........../.......... D
A A
INLET OUTLET
TABLE
TANK LID
LID - CLASS D 2.5 t 1.8 t
900 x 900
NOTE:
C PLAN VIEW LIFTING WEIGHTS MAY VARY C
C:\Vault Working Folder\Designs\SPEL\PRODUCTS\FILTER\EMC-45\STANDARD\04 FILTERS\CONCRETE\PROJECTS\SPEL PRECAST T44 TANK 3.7 kL\SP18-SF10170-P.idw
DEPENDING ON CUSTOM DESIGN
ISOMETRIC VIEW
3 OFF
I.D. 1730 SPEL FILTER EMC45
100
900 WEIR BOX
OVERALL HEIGHT 1825
INTERNAL H'T 1525
200
B B
O.D. 1930 100 SIDE VIEW PLAN VIEW
COVER & LID REMOVED FOR CLARITY
SECTION A-A
TOLERANCE: ALL DIMENSIONS 10mm UNLESS OTHERWISE STATED.
CLIENT: DISTRIBUTOR : The drawings must not be disclosed to any thirdDrawn Date PROJECT :
parties without written permission from SPEL Environmental Sydney.
Unauthorised disclosure may result in prosecution. P.Z. 21-03-18
SPEL Environmental - This drawing is the property of SPEL
Environmental ABN: 83 151 832 629 and is subject to return on Check Date
A demand. It is submitted for the use only in connection with the TITLE
SPEL PRECAST TANK A
proposal and contracts of SPEL Environmental with the expressed
Verified Date
conditions that it is not to be reproduced or copied in any form. 3.7 kL CLASS D
This data must only be used in accordance with our standard SF.169D/03-29.CON.300
terms and conditions. 3 SPEL FILTER CARTRIDGES
Copyright Approved Date
SPEL Environmental accepts no responsibility for any loss or SCALE SIZE
N.T.S SHEET REV
damage resulting from any person acting on this information. A3 1 1
The details and dimensions contained in this document may change, Request No.
please check with SPEL Environmental for confirmation of current RN1758 CUSTOMER CODE : DWG No.
specifications. SP18-SF10170-P
6 5 4 3 2 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Info Request - Attachment 4b - Engineering Report Part 2 MCU18-0015 & RAL18-0001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.