Council archive · source document
Approved Plans - 132007 616 05 (1) · 132007.616.05
Plans and drawings: the text below has words only, no drawings.
© COPYRIGHT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
-
DO NOT SCALE check all dimensions on site before fabrication or set out.
NOOSA COUNCIL DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
APPROVED PLAN BE 1 2 3 BW
132007.616.05 15 NOV 2018
5990 13390 1000 6000
RL63.14
Ridge
RL61.62
Roof
RL62.51
EL
Ridge
SW
RL61.64
Roof
24
EL
5090
omp RP89506
7000
omp SITE INFORMATION:
SW
56.26 56.15
S S
1
S S S S S R.P.D.:
.4
S S S S
56
S
EL
BS Lot No.: 23
1564
60
Plan No.: RP 89506
omp
SW
2064
SW SW SW SW SW SW SW SW SW SW Property No: 131944
A 1
GTP
ATTUNGA HEIGHTS
Area: 531m²
EL
71 56 .5 8
5
56.
9
STORMWATER:
.3
6
5
0
.5
POOL
6
5
5
7
Roof water to flow to street to join
D
7
2 AH
.7
D
.5
.7te
1
re
0
CRoLn5c6
HOUSE A
8
5
8495
5
8
existing council system via 90 dia
8
.1
.0
EL
in
.5
il
5
Na
6
9
57
0
.4
PAD RL 57.450 APPROX U.P.V.C. stormwater lines at 1:100
PROPOSED
9
57.5
GROUND FFL RL 57.700 minimum fall.
FIRST FFL RL 60.450 DUPLEX
5
.9
57.41
RETAINING WALLS:
60
SECOND FFL RL 63.580 LOT 23 on RP 89506
EL
If required all retaining walls shall be
5
23
8
57.13 57.01
.1
3
2 provided in strict accordance with
58
Bitumen
Edge of
Kerb
Back of
B
5 .0
engineers detailed design and local
6
0
.8
4
HOUSE B
58.76
authority requirements.
EL
PAD RL 57.950 APPROX
GROUND FFL RL 58.200 Wind Classification: N2
57.5
59.56 58
FIRST FFL RL 60.950 [Refer Soil Report]
.9 0
9 57.5
6
SECOND FFL RL 64.080
1
59
.2
8995
6
.5
7
6
0
EL
5
Soil Classification:
0
.2
60
.9
TBA
3
7
6
0
57.50
.4
57.66
6
[Refer Soil Report]
6
6
3
1
1
Climate Zone:
.6
.3
2
5
8
5
EL
9
.7
2
[Refer Energy Efficiency Report]
POOL
57.
C
1064
Site Cover:
62 .5
95
60
BN
EL
D
Prop Site Cover 206.1 m² 38.7 %
58.
Kerb
RL58.04 AHD
Nail in
Footpath
Concrete
EL 04
102001
RL67.59
Roof
RL65.24 58.11
58.1
58.2
Deck RL67.59
58.13
4 CP
Roof
9
BUP105477
0
Ridge
RL68.89
SITE
8 ATTUNGA HEIGHTS
EL
NOOSA HEADS QLD 4567
PROJECT
RL67.59
Roof
RL69.89
Ridge
DUPLEX DEVELOPMENT
CLIENT
TIKE PROPERTY Pty Ltd
DRAWING TITLE
PROPOSED SITE PLAN
DESIGNED SCALE
BDH 1 : 200
CHECKED STAGE - ISSUE
BDH BA - 11
DRAWN DATE
MAJ 30.10.2018
PROJECT No. PAGE No.
18020 D04 OF 19
0 2 4 6 8 10m
1: 200
1 3 0 0 1 3 3 9 1 7
[email protected]
SITE PLAN
1 Scale: 1 : 200
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:05:41 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 9 (of 11)
Page 2
© COPYRIGHT | All rights reserved. This work is copyright and canot be
BE 1 2 3 BW reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
1400 190 3010 190 1200
1800 high treated timber paling fence 2000
Planting to Landscape arcitect's design
S S S S S S S S S S S
Pool filter and pump
RL 61150 (tow) S
EL
BS
1564
SW
SW SW SW SW SW SW SW SW SW SW
A
190
M/B RL 59300 (tow)
Tiling/ coping to Planting to Landscape
selection arcitect's design
EL
DECK Field gully for surface drainage to
Raised planter to suitable council approved drainage
Fremeless glass pool RL 58500 (tow) Landscape point
fencing and gate to BCA
arcitect's design
& QLD pool regulations RL 57400
6010
Relocated existing plants
1800 deep pool to POOL
engineer's design Existing crossover to be
GARAGE removed and made good
EL
RL 61550 (tow)
ALFRESCO RL 57400
Planting to Landscape DINING 1200 high 290mm concrete block wall
arcitect's design rendered and painted to selection
1800 high treated RL 59300 (tow)
timber paling fence
190
KITCHEN RL 57400 2/ Rear opening & lockable stainless
steel letterboxes to comply with
AC COND
S
Australia Post requirements
RL 58700
EL
Concrete block retaining
2010
wall reinforeced and Turf
PDR ENTRY
S 1:17
RL 57750
core filled to engineer's P'TRY STAIRS
HWS
design
Trellis fixed to wall
190
B AC COND for vertical planting
HWS
1800 high P/C Alum PDR STAIRS ENTRY LIFT
4500
batten screen and gate PANTRY RL 59100 1:9
EL
RL 61750 (tow) S
RL 57600
S
1:64 1:48 1:6
KITCHEN RL 59100
RL 58100
Concrete block retaining RL 59600 (tow)
DINING Exposed or coloured concrete
wall reinforeced and STORE
EL
Raised planter to driveway to client selection with
core filled to engineer's Landscape crossover to council requirements
9964
design Turf
arcitect's design
1200 high frameless glass SITE
pool fence and gate
DECK 8 ATTUNGA HEIGHTS
1:21 NOOSA HEADS QLD 4567
Strip drain PROJECT
GARAGE
EL
DUPLEX DEVELOPMENT
190
1750
RL 57600 Planting to Landscape CLIENT
arcitect's design TIKE PROPERTY Pty Ltd
Synthetic turf RL 60000 (tow)
POOL M/B DRAWING TITLE
2350
DN
EXTERNAL WORKS PLAN
C
14 190 1250
RL 62150 (tow) DESIGNED SCALE
BDH 1 : 100
190
CHECKED STAGE - ISSUE
BN BDH BA - 11
EL
DRAWN DATE
1800 high treated RL 61950 Planting to Landscape
MAJ 30.10.2018
timber paling fence arcitect's design - PROJECT No. PAGE No.
Pool filter and pump under NOOSA COUNCIL 18020 D05 OF 19
EL
0 1 2 3 4 5m
2190
190
2910
190
510 7600
190 APPROVED PLAN
132007.616.05 15 NOV 2018 1: 100
1 3 0 0 1 3 3 9 1 7
[email protected]
EXTERNAL WORKS PLAN
1 Scale: 1 : 100
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:05:46 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 3
BE 1 2 3 BW © COPYRIGHT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
5990 13390 1000 6000 DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
1400 190 3010 190 1200 190 5070 140 6000 190 1800 7000
pool
190 5070 140 4500 90 1410 190 1800 7000
200
190 4470 140 90 6310 190 1610 190 4810 190 2000
BS
B A
1564
SW
SW SW D12
SW SW D11 D12
SW SW SW SW
4 SW
DP
190
A
190
190
190
NBN ISB M/B -
STORE
NOOSA COUNCIL
04-12 AW
LDR'Y
APPROVED PLAN
HOUSE A 132007.616.05 15 NOV 2018
POOL
5510
21-34 PLD
7000
7000
6910
6960
GARAGE
8495
8210
STORE
C C
D13 D13
90
LETTERBOXES
24-920
820
820
190
DP
entry
2610
ENTRY
90 575 190 1160 140
90 1160 190 1160 90
720
D11 3
1 D10
1210
NOTE: Mechanical Ventilation to B.C.A
S LIFT
lift
MV Part 3.8.5. Duct externally.
2990
190
190
190
B
DRY WM NOTE: Smoke Alarms to be photoelectric
1210
720
LIFT
lift
to AS3786-2014 and hardwired
S
820 CSD
70 150 190
2810 entry
TUB and interconnected. Provide
Smoke Alarms to all bedrooms,
LINEN L'DRY
720
ENTRY halls and each floor as per QFES
820
& QLD building regulations.
1310
24-920
1090
D S D
WALL LEGEND
5560
D13 D13
190
90
4895
STORE DP EXISTING STUD/ BLOCK WALL
4310
70/90mm TIMBER STUD WALL
2660
2660
CONCRETE BLOCK WALL
8995
TO ENGINEER'S DESIGN
CONCRETE BLOCK PARTY
WALL TO ENGINEER'S DESIGN.
REFER DETAILS 1
140
140
140
140
140
35
6190
SITE
21-34 PLD
8 ATTUNGA HEIGHTS
NOOSA HEADS QLD 4567
3010
3010
3010
3010
3010
GARAGE DUPLEX DEVELOPMENT
PROJECT
HOUSE B
CLIENT
TIKE PROPERTY Pty Ltd
NBN ISB M/B DRAWING TITLE
190
190
190
190
190
E BASEMENT FLOOR PLAN
C D14 2 DP DESIGNED SCALE
1064
B A D10 BDH 1 : 100
D12 D12
CHECKED STAGE - ISSUE
BN 200 BDH BA - 11
190 90 90 90 90 190 190 DRAWN DATE
5990 1610 2820 1060 3660 1500 1610 MAJ 30.10.2018
90 entry 190
PROJECT No. PAGE No.
190
5990 9710 1410 600 1200 18020 D06 OF 19
0 1 2 3 4 5m
190 190
5990 11810 8200
garage 1: 100
1 3 0 0 1 3 3 9 1 7
12190 1200 7000 [email protected]
BASEMENT FLOOR PLAN
1 Scale: 1 : 100 PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:05:48 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 4
© COPYRIGHT | All rights reserved. This work is copyright and canot be
BE 1 2 3 BW reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
5990 13390 7000 DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
1400 190 3010 190 1200 190 4710 190 4910 490 2410 490 600
90 2720 90 2100 90 6280 90 1830 100
kitchen alfresco 200 dining living deck
90 2920 90 1610 9090 1060 4000 1250 190 1610 190
ptry pdr stairs lift
BS
1564
1564
1564
B D11 A -
2064
D12 D12
4 NOOSA COUNCIL
A
190
DP DP APPROVED PLAN
190
390
132007.616.05 15 NOV 2018
2810
GATE
3210
deck
2310
deck
2120
1920
2710
DECK
15-15 DH
90
400
DP
6010
24-24 SGD
POOL
90
ALFRESCO
alfresco
2000
24-24 SGD
8495
3050
LIVING
06-24 FGF
DINING
dining / living
RH HP
kitchen
UBO
KITCHEN
4250
24-36 STK
3790
C C
3850
100
D13 SHS D13
5685
HOUSE A
Screen
710 90 1340 90190 1160 90 1200 90
1690
190
screen
hall
REF
AC COND
S
Screen Gates
Plumbing duct
70 190 stairs 190 stairs 190
24-820 CSD 24-720 CSD
1580 190 1160 90
90
2010
D11 3 DP
1400
1 D10
1210
P'TRY PDR NOTE: Mechanical Ventilation to B.C.A
1160
ptry 150 ptry
pdr
LIFT
lift 190 lift
DN UP
HWS MV Part 3.8.5. Duct externally.
STAIRS
190
190
B
screen
AC COND
HWS STAIRS NOTE: Smoke Alarms to be photoelectric
24-720 CSD
1160
P'TRY P'TRY
1210
1400
DW
Screen Gate SINK
PDR DN UP LIFT S
to AS3786-2014 and hardwired
and interconnected. Provide
24-720
PANTRY
90
WC Smoke Alarms to all bedrooms,
150
24-820 CSD halls and each floor as per QFES
90
S & QLD building regulations.
MW
Screen
Plumbing duct
4675
1690
REF
WO
D
D13 RH HP HOUSE B D
D13 WALL LEGEND
kitchen
07-24 BF 4L
2820
KITCHEN
living 100
EXISTING STUD/ BLOCK WALL
dining
DP
4330
2110
24-36 STK
SHS
3960
DW SINK
DINING 70/90mm TIMBER STUD WALL
CONCRETE BLOCK WALL
8995
LIVING TO ENGINEER'S DESIGN
90
90
9760
CONCRETE BLOCK PARTY
1090
Cast concrete steps WALL TO ENGINEER'S DESIGN.
REFER DETAILS 1
2330
Alum batten screen gates 35
90
90
2830
5710
24-40 STK
1240
SITE
Pool pump & filter under
1630
concrete enclosure DECK 8 ATTUNGA HEIGHTS
NOOSA HEADS QLD 4567
390
390
Strip drain PROJECT
DUPLEX DEVELOPMENT
0
13190 190 1410 190
DP
4294
CLIENT
TIKE PROPERTY Pty Ltd
Synthetic turf
POOL
2460
2663
2664
DRAWING TITLE
pool gate
DN
E E GROUND FLOOR PLAN
C D14 2 D14
DESIGNED SCALE
1064
1063
560
B A D10 BDH 1 : 100
D12 Planting D12
14190
190
CHECKED STAGE - ISSUE
BN 255 BDH BA - 11
13
90 90 90 90 190 190 DRAWN DATE
5990 3680 850 1005 4000 1250 1610 lift MAJ 30.10.2018
90 ldry pdr 90 stairs 70 90 100 PROJECT No. PAGE No.
5990 4965 6225 860 900 18020 D07 OF 19
kitchen dining living duct deck 0 1 2 3 4 5m
5990 4945 7445 1000 7000
190 190 190 1: 100
1 3 0 0 1 3 3 9 1 7
2190 3610 4710 4910 490 2410 490 600 6400 [email protected]
GROUND FLOOR PLAN
1 Scale: 1 : 100 PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:05:52 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 5
© COPYRIGHT | All rights reserved. This work is copyright and canot be
BE 1 2 3 BW reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
DO NOT COPY in any form or by means (graphic, electronic or mechanical,
5990 11460 1930 7000 including photocopying) without the written permision of Mercury Design.
90 3005 9051090 1550 90 1620 90 4240 90 1930 7000
bed 2 ens wir bed 1 deck
90 2488 690 1237 90 6780 90 1930
bed 2 bed 2 hall
90 4415 90 410 901060 4000 90 1160 190 1610 190
ens stairs hall lift
BS 3390 600
Quatro GRC Trough Planters
1564
1000l x 400w x 740h (or similar)
B D11 A 1000mm high S/S cable
2064
D12 2000mm high trellis -horizontal S/S D12 balustrade. Refer detail
4
cables at 300mm over balustrade
A
DP DP
190
390
390
-
NOOSA COUNCIL
2810
2310
2310
2310
2310
2120
1920
1920
APPROVED PLAN
09-18 AW 06-09 AW 09-18 AW DECK 132007.616.05 15 NOV 2018
90
90
90
90
90
DP
NRG SURROUND
WC
24-21 MSD
820 CSD
820 CSD
ENS
ROBE
2620
21-24 SGD
WIR
wir
bed 1
bed 1
MASTER
3130
3130
3130
06-24 AW
VB
ens
bed 2
3560
BED 2
balc
4190
4190
C C
D13 S D13
AC
190 1160 90 1030 9042090
30
10 AC
st
Screen
SHR
190 1160 901030 90
90
hall 90
820
820 CSD 810
1030
S
770
90
hall
hall
820
ENS
S
HOUSE A
190
06-12 AW
FW
2280
90
BATH
1850
D11 3
ens
DP
ens/lin
SHR
LINEN
2/520
VB VB 1 D10
1210
stairs
90 lin hall 90 stairs 190 stairs
NOTE: Mechanical Ventilation to B.C.A
1160
10360
lift
DN
WC
STAIRS LIFT MV Part 3.8.5. Duct externally.
2990
190
190
190 hall 190
B
STAIRS NOTE: Smoke Alarms to be photoelectric
1160
1210
WC
06-12 AW
1400
SHR
LIFT
lift
to AS3786-2014 and hardwired
90 1580
90 1030 90 1580
DN
18054
ens
shr
1850
S
BATH
ens
VB VB and interconnected. Provide
FW
90
ENS Smoke Alarms to all bedrooms,
halls and each floor as per QFES
HOUSE B
510 1000
1610 90
S 720 CSD & QLD building regulations.
03-12 SW
820 CSD
90
Screen
BATH
hall
820
bath
1610
1790
S
ens
90 90
820 2/620 VB
D D
D13 AC LINEN ROBE SHR D13 WALL LEGEND
WC
bed 1
2820
bed 1
S
MASTER AC 820
2550
EXISTING STUD/ BLOCK WALL
90
DP
24-12 MSD
NRG SURROUND
ROBE
70/90mm TIMBER STUD WALL
bed 2
145
bed 2
2790
CONCRETE BLOCK WALL
2640
BED 2
bed 2
2390
2480
06-18 AW
TO ENGINEER'S DESIGN
1090 90
90
21-31 STK CONCRETE BLOCK PARTY
1090
3920
WALL TO ENGINEER'S DESIGN.
REFER DETAILS 1
35
1630 90
90
90
deck
2720
21-24 SGD 21-24 SGD
1240
SITE
DECK
deck
deck
1630
1630
1630
8 ATTUNGA HEIGHTS
PLANTER PLANTER NOOSA HEADS QLD 4567
390
PROJECT
190
DP DUPLEX DEVELOPMENT
4294
CLIENT
2400mm high balustrade/ trellis -
TIKE PROPERTY Pty Ltd
horizontal S/S cables at 100mm crs
with handrail at 900mm high
2664
2664
2664
2664
2663
2663
2663
DRAWING TITLE
E E FIRST FLOOR PLAN
C D14 Quatro GRC Trough Planters 2 D14
DESIGNED SCALE
B 1000l x 400w x 740h (or similar) A D10 BDH 1 : 100
D12 D12
CHECKED STAGE - ISSUE
90 90 90 190 190
BN 4910 4310 1910 1610 BDH BA - 11
DRAWN DATE
90 90 ens 90 90 stairs 90 90 90 lift 90 MAJ 30.10.2018
1390 2450 2010 1600 1420 1030 2770 PROJECT No. PAGE No.
90 ens bed 1 90 90hall bed 2 linen robe bath90 18020 D08 OF 19
3930 610 7490 1000 0 1 2 3 4 5m
bed 1 rb bed 2
18 5990 4720 7670 1000 1: 100
1 3 0 0 1 3 3 9 1 7
13390 7000 [email protected]
FIRST FLOOR PLAN
1 Scale: 1 : 100 PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:05:56 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 6
© COPYRIGHT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
BE 1 2 3 BW DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
3370
10920 1740 1630
900 10020 1420 320
BS
2064
A DP
DP
Line of block below as per
-
engineer's details
1410
1410
2° NOOSA COUNCIL
DP
Colorbond Klip-lok 700 roof
sheeting on battens fixed to
APPROVED PLAN
900
900
manufacturer's specifications 132007.616.05 15 NOV 2018
Rafters at 2° pitch as per
6500
engineer's design
Colorbond gutter and fascia as
per selection
4190
6490
Prefabricated timber skillion roof
7°
trusses with 300mm upstand
designed and installed to
manufacturer's specifications
DP
Block party wall to underside of
roof sheeting
190
B
Line of block/ lift shaft below
4780
Colorbond Custom orb roof
sheeting on battens fixed to
manufacturer's specifications
RL 68090 5° DP
7500
Prefabricated timber skillion roof
2480
trusses with 300mm upstand
designed and installed to
1090
manufacturer's specifications
2730
NRG Surround fixed to
manufacturer's specifications SITE
1640
1640
8 ATTUNGA HEIGHTS
Colorbond gutter and fascia as NOOSA HEADS QLD 4567
PROJECT
per selection DUPLEX DEVELOPMENT
DP CLIENT
TIKE PROPERTY Pty Ltd
Line of block below as per
2654
2654
DRAWING TITLE
engineer's details
ROOF PLAN
C DESIGNED SCALE
BDH 1 : 100
CHECKED STAGE - ISSUE
BN BDH BA - 11
DRAWN DATE
900 4720 7670 1000
MAJ 30.10.2018
PROJECT No. PAGE No.
5090 14290 7000 18020 D09 OF 19
0 1 2 3 4 5m
1: 100
1 3 0 0 1 3 3 9 1 7
[email protected]
ROOF PLAN
1 Scale: 1 : 100
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:05:57 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 7
BN C B A BS © COPYRIGHT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
Lift core concrete block walls reinforced
Colorbond Custom Orb roof and core filled to engineer's details,
sheeting on trusses at 900crs rendered with grooves and painted.
to engineer's design
Powdercoated alum louvre screen
7°
B-Roof
66480 8m above NGL at the boundary
A-Roof
65880
Powder coated aluminium
2600
screen installed to Hardies Scyon Axon 400 FC
manufacturer's specifications
2600
cladding fixed to manuf's specs
1000mm High frameless glass
B-First Floor
balustrade to BCA part 3.9.2
380
63880
A-First Floor
380
Texture coated polystyrene 63280
(NRG or sim) surround moulds
fixed to manufacturer's specs Powdercoated alum louvre screen
2750
Hardies Scyon Axon 400 FC
2750
cladding fixed to manuf's specs
B-Ground Floor
Suspended concrete slab to
300
60750
engineer's details A-Ground Floor
300
60150
Concrete block walls reinforced
and core filled to engineer's details,
2850
Rendered and painted to selection
2450
B-Basement
200
57600 A-Basement
57400
WEST ELEVATION Rear opening and lockable letterbox
1 Scale: 1 : 100
with signage to client selection
-
BE 1 2 3 BW NOOSA COUNCIL
APPROVED PLAN
5° 8m above NGL at the boundary 132007.616.05 15 NOV 2018
Aluminium privacy screens installed to
manufacturer's specifications
B-Roof
66480
Colorbond fascia and gutter, to
selection, fixed to manuf's specs
Rendered and painted concrete block
2600
columns to engineer's details Hardies Scyon Axon 400 FC
cladding fixed to manuf's specs
Full height stainless steel cables at
B-First Floor 100mm crs with handrail at 900 high SITE
500
380
63880 to comply to balustrade to BCA part 8 ATTUNGA HEIGHTS
above ground
3.9.2 and pool barrier MP3.4 NOOSA HEADS QLD 4567
PROJECT
Ground line of
1500
Block wall 1000mm min above line of coping DUPLEX DEVELOPMENT
1850
subject property CLIENT
2750
E TIKE PROPERTY Pty Ltd
Approx ground line of D14
adjoining property Suspended concrete slab DRAWING TITLE
to engineer's details ELEVATIONS
1600
DESIGNED SCALE
B-Ground Floor
300
60750 BDH 1 : 100
CHECKED STAGE - ISSUE
above NGL
BDH BA - 11
Pool 1000
Line of pool behind Approx height and location of DRAWN DATE
to engineer's details existing timber retaining wall with MAJ 30.10.2018
1800 high timber paling fence over PROJECT No. PAGE No.
Concrete block retaining walls reinforced 18020 D10 OF 19
3100 8490 4400 2400 and core filled to engineer's details, 0 1 2 3 4 5m
Rendered and painted to selection
1: 100
1 3 0 0 1 3 3 9 1 7
[email protected]
NORTH ELEVATION
2 Scale: 1 : 100
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:06:18 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 8
BS A B C BN © COPYRIGHT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
DO NOT COPY in any form or by means (graphic, electronic or mechanical,
EFL-01 ECL-01 including photocopying) without the written permision of Mercury Design.
8m above NGL at the boundary
Colorbond barge flashing
4.5mm Soffit FC sheeting fixed
EPS-01 to battens on rake
B-Roof
7° 66480
A-Roof Rendered and painted concrete block
65880
Texture coated polystyrene columns to engineer's details
2600
ECL-01
(NRG or sim) window surround
fixed to manufacturer's specs 1000mm High frameless glass
2600
balustrade to BCA part 3.9.2
Hardies Scyon Axon 400 FC B-First Floor
380
cladding fixed to manuf's specs 63880
A-First Floor
380
63280
Line of concrete block retaining wall
(in foreground, remove for clarity)
2750
2750
Existing ground line
B-Ground Floor
300
60750
A-Ground Floor
300
60150
2850
2450
B-Basement
A-Basement 57600
57400
EAST ELEVATION
3 Scale: 1 : 100 3 2 NOOSA COUNCIL
-
1 BE
APPROVED PLAN
BW
132007.616.05 15 NOV 2018 8m above NGL at the boundary
Lift core concrete block walls reinforced Colorbond Custom Orb roof sheeting
and core filled to engineer's details, on trusses at 900crs to engineer's design
Rendered and painted to selection
Colorbond fascia and gutter, to selection,
fixed to manuf's specs
A-Roof
65880
Hardies Scyon Axon 400 FC
Aluminium privacy screens installed to
cladding fixed to manuf's specs
manufacturer's specifications
2600
1000mm High frameless glass
balustrade to BCA part 3.9.2 Rendered and painted concrete block
columns to engineer's details
Concrete block walls reinforced and
A-First Floor core filled to engineer's details, SITE
8 ATTUNGA HEIGHTS
380
63280 Rendered and painted to selection
NOOSA HEADS QLD 4567
PROJECT
DUPLEX DEVELOPMENT
1000mm High frameless glass CLIENT
balustrade to BCA part 3.9.2 TIKE PROPERTY Pty Ltd
2750
Aluminium framed doors and
Suspended concrete slab to windows installed to DRAWING TITLE
engineer's details manufacturer's specifications ELEVATIONS
DESIGNED SCALE
A-Ground Floor BDH 1 : 100
300
60150 CHECKED STAGE - ISSUE
Hardies Scyon Axon 400 FC BDH BA - 11
cladding fixed to manuf's specs DRAWN DATE
MAJ 30.10.2018
2450
Concrete block walls reinforced PROJECT No. PAGE No.
and core filled to engineer's details, 18020 D11 OF 19
Rendered and painted to selection 0 1 2 3 4 5m
A-Basement
57400 1: 100
1 3 0 0 1 3 3 9 1 7
[email protected]
SOUTH ELEVATION
4 Scale: 1 : 100 PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:06:36 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
Page 9
© COPYRIGHT | All rights reserved. This work is copyright and canot be
BN C B A BS reproduced or use figured dimensionsions.
DO NOT SCALE check all dimensions on site before fabrication or set out.
DO NOT COPY in any form or by means (graphic, electronic or mechanical,
including photocopying) without the written permision of Mercury Design.
Colorbond Custom Orb roof Rock wool insulation to top of party wall
sheeting on trusses at 900crs to SECTION NOTES
manufacturer's design Colorbond gutter and fascia to client specs 1) CONCRETE SLAB, BLOCKWORK &
B-Roof FOOTING DESIGN TO ENGINEERS
66480 SPECIFICATIONS ON 0.2mm & 50mm
Concrete block wall party wall A-Roof MINIMUM SAND BEDDING
LINEN
reinforced and core filled to 65880 2) 200 SERIES BLOCKWORK CORE FILLED
4.5mm Soffit sheeting fixed on rake
ceiling
frame
2600
2550
engineer's details with DECK BED 2 AND REINFORCED TO ENGINEER'S
joinery
STAIRS Timber wall frame to engineer's details
2100
plasterboard on battens with SPECIFICATION
MASTER DECK
ceiling
frame
STAIRS HALL and insulated to energy efficiency report
2600
2550
joinery
insulation as per detail 1 3) DISCONTINUOUS CONSTRUCTION TO
2100
35 Tiles on waterproof CFC deck DETAIL WITH 1x13mm GYPROCK
B-First Floor PLASTERBOARD CD & TSB4/ASB4
380
63880 Timber floor frame to engineer's details POLYESTER BATTS AS PER ACCOUSTIC
A-First Floor REQUIREMENTS
380
63280 4) PARTY WALLS TO EXTEND TO UNDERSIDE
LIVING OF ROOF SHEET FIRE PROOF MINERAL
ceiling
WOOL OVER WHERE NOT PROTUDING
frame
Line of NGL at face DECK
2750
LIVING DECK
2700
joinery
2400
of pool wall 5) EXTERNAL BLOCK WALLS RENDERED &
ceiling
frame
PAINTED TO SELECTION WITH EXPRESSED
2750
2700
joinery
2400
HOUSE B ARTICULATION JOINTS AS SHOWN
B-Ground Floor HOUSE A 6) 10mm PLASTERBOARD LINING TO
300
60750 INTERNAL 70/90mm STUD PARTITION WALLS
A-Ground Floor 7) 10mm PLASTERBOARD LINING ON
300
60150 28mm METAL BATTENS TO BLOCK WALLS
Suspended concrete floor to (NON PARTY WALLS)
GARAGE STORE
frame
engineer's details 8) COLORBOND CUSTOM ORB ROOFING
2850
ceiling
2400
joinery
GARAGE
ceiling
@ 5° PITCH WITH 75 ANTICON BLANKET OR
frame
2100
2450
2400
joinery
2100
SIMILAR INSULATION TO SELECTION OVER
Concrete block wall/ retaining METAL PURLINS @900ctrs ON TIMBER
TRUSSES TO MANUFACTURERS
reinforced and core filled to engineer's
B-Basement SPECIFICATIONS @900ctrs WITH 10mm
200
details A-Basement PLASTERBOARD CEILING TO 28mm METAL
57600
57400 CEILING BATTENS @450ctrs
SECTION concrete slab and foundations to (NOTE: BATTENS MAY NEED TO BE
A Scale: 1 : 100 -
engineer's details INSTALLED @450ctrs TO COMPLY WITH
WORKPLACE HEALTH & SAFETY
REQUIREMENTS IF NO OTHER METHOD OF
NOOSA COUNCIL FALL ARREST IS ADDRESSED)
BN C B
APPROVED PLAN A BS
9) COLORBOND GUTTER AND DOWNPIPES
TO MATCH ROOFING TO SELECTION.
132007.616.05 15 NOV 2018 'OPTION' TIMBER OR COLORBOND FASCIA
TO MATCH ROOFING
10) ALL JOINERY AT 2100/2400 HEAD
Colorbond Custom Orb roof HEIGHT (UNO) TO SELECTION
sheeting on trusses at 900crs to Rock wool insulation to top of party wall
11) VERTICAL ALUMINIUM BLADE
manufacturer's design
SCREENING WITH FINISH TO CLIENT
Colorbond gutter and fascia to client specs SELECTION.
B-Roof
66480 12) TREADS & RISERS TO COMPLY WITH
Concrete block wall party wall A-Roof B.C.A. PART 3.9.1.4
65880 BALUSTRADE & HANDRAILS TO COMPLY
reinforced and core filled to 4.5mm Soffit sheeting fixed on rake
ceiling
WITH B.C.A. PART 3.9.1.5
frame
DECK MASTER
2600
2550
engineer's details with
joinery
ENS Timber wall frame to engineer's details
2100
plasterboard on battens with 13) FULL TERMITE TREATMENT SYSTEM TO
ceiling
frame
and insulated to energy efficiency report
2600
DECK
2550
A.S. 3660 BY LICENCED INSTALLER
joinery
insulation as per detail 1
ENS BED 2
2100
(SYSTEM TO PROVIDE 50 YEAR SERVICE
35 Tiles on waterproof CFC deck GUARANTEE)
B-First Floor
380
63880 SITE
A-First Floor 8 ATTUNGA HEIGHTS
380
Raised planter bed 63280
NOOSA HEADS QLD 4567
PROJECT
DECK KITCHEN PANTRY DUPLEX DEVELOPMENT
ceiling
frame
Timber floor frame to engineer's details
P'TRY KITCHEN DECK
2750
2700
joinery
2400
CLIENT
TIKE PROPERTY Pty Ltd
ceiling
frame
2750
2700
joinery
POOL
2400
DRAWING TITLE
B-Ground Floor
Suspended concrete floor to SECTIONS
300
60750 engineer's details DESIGNED SCALE
A-Ground Floor BDH 1 : 100
300
60150 CHECKED STAGE - ISSUE
BDH BA - 11
GARAGE STORE DRAWN DATE
frame
2850
MAJ 30.10.2018
ceiling
2400
joinery
ceiling
STORE
frame
Concrete block wall/ retaining
HOUSE B
2100
2450
2400
joinery
PROJECT No. PAGE No.
2100
reinforced and core filled to engineer's 18020 D12 OF 19
B-Basement
HOUSE A details 0 1 2 3 4 5m
200
57600 A-Basement 1: 100
57400 1 3 0 0 1 3 3 9 1 7
[email protected]
SECTION concrete slab and foundations to
B Scale: 1 : 100
engineer's details
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
30/10/2018 6:06:41 PM
Document Set ID: 20726466
Version: 1, Version Date: 02/11/2018
The text continues on page 10.
Used in these records
Approved Plans - 132007 616 05 (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.