NI2 AT 200 6 (CENTRAL) N12 AT 200 A (CENTRAL) 2 Nib TRIMMERS EACH SIDE OF PENETRATION BASE SLAB SCALE 1:20 250 THICK SLAB ROOF SLAB SCALE 1:20 MESH - 250mm NI2) - 300mm NiS - 400mm NOTES: N20. - 500mm 1, MAINTAIN COVER TO REBATE AT ALL PIPE PROTRUSIONS. + 600mm + 800mm 000mm -1200mm 2. ALL CONCRETE TO BE N&O Tan LAL SORE 3, REINFORCEMENT NOT NOMINATED ON LAYOUT TO BE NIZ “A” FIRST (BOTTOM) LAYER @ 200 UNO 45mm BTM COVER EXTERNAL 4, DISTRIBUTION REINFORCEMENT TO BE N12 @ 200. “8” SECOND LAYER BAR LAYING SEQUENCE “D" LAST (TOP) LAYER 45mm TOP COVER EXTERNAL 00 02 06 06 88 10 69 09 02 03 Ob 05 “C" THIRD LAYER SCALE 1: 20 AT Al SCALE 1: 10 AT Al NOTES: ‘L This is the property of the engineer, and may not be used, copied, of reproduced wholly, of in part without the express permission of the engineer, Infringement in any woy may result in legal action, 1. Figured dimensions take recederne over scaled. 2 Verify cll Gimensions on site, ROOF SLAB REINFORCEMENT 40mm TOP COVER SCALE 1:20 N16 AT 200 B 2. N16 TRIMMERS NI6 AT 200 A EACH SIDE OF PENETRATION ROOF SLAB BOTTOM REINFORCEMENT 40mm _ COVER SCALE 1:20 CONCRETE NOTES: a ALL CONCRETE WORK AND REINFORCEMENT TO BE EXECUTED IN ACCORDANCE WITH THE RELEVANT S.A.A CODES AND SPECIFICATIONS: IN PARTICULAR AS 3600 CURRENT EDITION, REFER DRAWINGS FOR CONCRETE COMPOSITION AND QUALITY, CONCRETE TESTING TO CONFORM WITH THE ACCEP- TABILITY REQUIREMENTS OF THE CURRENT EDITION OF AS 3600. THE CONCRETE SLUMP SHALL NOT BE LESS THAN 75mm AND NOT MORE THAN 100mm, ALL CONCRETE IS TO BE VIBRATED IN ACCORDANCE WITH AS 3600; NO WATER BE ADDED ON SITE OR IN TRANSIT FROM BATTERY PLANT. TITLE: BARLOW GREGG Wema_| STORMWATER STRUCTURE REINFORCEMENT DETAILS ARN 710 37 93 ACH T0957 93 ‘SUNSHINE COAST: FRASER (GAST: 24 woton Street, Poane 7) O08 3955 CORAL COAST: Pate WT) O52 SS WeaTSEAY COAST, Pace #71 O94 AAT? ‘ASSOUATED CONSIA TANTS Fax (071 Sent O56 ee! Ph: (07) 5443 2064 KEN HICKS & ASSOCIATES Fox: (07) 5463 7166 SL 82 FABRIC POSITION BAR MID - GAP BETWEEN PIPE’S 2:N12 FULL LENGTH OF STRUCTURE LAY OVER “CRANK” AS REQUIRED TO AVOID EXISTING PIPES NIZ C 200 EACH WAY, (CENTRAL) N12 AT 200 EACH WAY N16 AT 200 EACH WAY. 40 COVER 40 COVER SECTION SCALE 1:10 (SIMILAR REINFORCEMENT GETAILS FOR SOUTHERN WALL OF STRUCTURE) NO HOLES, CHASES OR VOIDS, OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS ARE TO BE MADE WITHOUT PRIOR APPROVAL OF THE SUP- ERINTENOENT. MIN. CLEAR COVER TO ALL REINFORCEMENT (UNLESS SHOWN OTHERWISE) TO BE IN ACCORDANCE WITH REQUIREMENTS OF AS 3600 AS NOTEO IN THE DWG’S. ALL CONCRETE SHALL BE ADEQUATELY VIBRATED INTO PLACE, AND CURED CONTINUOUSLY FOR NOT LESS THAN SEVEN (7) DAYS IN AN APPROVED MANNER. MAXIMUM CONCRETE AGGREGATE SIZE TO BE 20mm U.N.O. » ALL DIMENSIONS SHOWN IN MILLIMETRES. PROJECT: LOT RECONFIGURATION at LOT 1 SP 182880 EENIE CREEK ROAD NOOSAVILLE [ ove: MARCH 2007 | MARCH 2007 [ sca: AS SHOWN | a [emcee enn PROJECT -SUBSET-SHEET-REVISION M3048 -C48
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Application part 1 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.