                                                                                                                                                                                                                                       ASSET REGISTER - WATER RETICULATION                                                                                                   GENERAL NOTES
                                                                                                                                                                                                                                ESTATE/STAGE        TEWANTIN - 7 LOT SUBDIVISION                                                                                             1.      ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT SOUTH EAST QUEENSLAND WATER SUPPLY CODE
                                                                                                                                                                                                                                                                                                                                                                                     SPECIFICATIONS AND STANDARDS.
                                                                                                                                                                                                                                SITE ADDRESS        GYMPIE STREET, TEWANTIN
                                                                                                                                                                                                                                                                                                                                                                             2.      UNLESS SPECIFIED OTHERWISE ALL MATERIALS AND WORK SHALL COMPLY WITH THE RELEVANT AUSTRALIAN STANDARDS.
                                                                                                                                                                                                                                                                                                                                                                             3.      ADOPT LIP OF KERB OR SHOULDER OF ROAD AS PERMANENT LEVEL.
                                                                                                                                                                                                                                APPLICATION No.     -
                                                                                                                                                                                                                                                                                                                                                                             4.      COVER ON MAINS FROM PERMANENT LEVEL TO BE AS PER SEQ CODE SECTION 7.4.2
                                                                                                                                                                                                                                                                                                                                                                             5.      CONDUITS TO BE INSTALLED IN ACCORDANCE WITH THE STANDARD DRAWINGS.
                                                                                                                                                                                                                                                                                                                                                                             6.      A WATER METER SUPPLIED AT THE DEVELOPERS'S COST, IS TO BE INSTALLED AT THE SERVICE POINT OF EACH LOT IN ACCORDANCE
                                                                                                                                                                                                                                                                                                                                                                                     WITH THE STANDARD DRAWING FOR THE UNITYWATER.
                                                                                                                                                                                                                                                                                                                                                                             7.      ALL MATERIALS USED IN THE WORKS SHALL COMPLY WITH THE URBAN UTILITES ACCEPTED PRODUCTS AND MATERIALS LIST OR BE
                                                                                                                                                                                                                                APPROVAL DATE                                                            -                                                                           APPROPRIATELY SHOWN, LISTED AND DEFINED IN THE ENGINEERING SUBMISSION SO THAT THE ALTERNATIVE PRODUCT OR MATERIAL
                                                                            6                         7                                                                                                                                                                                                                                                                              CAN BE ASSESSED AND IF APPROPRIATE, APPROVED BY THE URBAN UTILITES.
                                                                         1038m²                       1079m²                                                                                                                                                                                                                                                                 8.      TEST/CHLORINATION POINTS TO BE INSTALLED IN ACCORDANCE WITH STANDARD DRAWING No. SEQ-WAT-1410-1.
                                                                                                                                                                                                                                CLIENT                                                                   NOVATO GROUP PTY LTD                                                9.      THE CONSTRUCTION OF THE WATER RETICULATION WORK SHOWN ON THIS DRAWING MUST BE SUPERVISED BY AN ENGINEER WHO
                                                                                                                                                                                                                                                                                                                                                                                     HAS RPEQ REGISTRATION. WORKS NOT COMPLYING WITH THIS REQUIREMENT WILL NOT BE PERMITTED TO CONNECT TO THE
                                                                                              5
                                                                                              824m²
                                                                                                                                                                                                                                DRAWING/PLAN No.                                                         C500 - C501                                                                 RETICULATION SYSTEM.




                                                                                                                                                   BUTLER STREET
                                                                                                                                                                                                                                                                                                                  MATERIAL                            LENGTH                 10.     MARKERS ARE REQUIRED FOR ALL HYDRANTS & VALVES IN ACCORDANCE WITH SEQ SPECIFICATIONS & STANDARDS.
                                                                                                                                                                                                                                                                       DIAMETER
                                                                                                                                                                                                                                                                                                             DESIGN      CONST                  DESIGN      CONST            11.     DEAD ENDS OF WATER MAINS TO BE CONSTRUCTED IN ACCORDANCE WITH SEQ SPECIFICATIONS & DRAWINGS.
                                                                                              4
                                                                                           711m²                                                                                                                                                                                                                                                                             12.     WHERE THERE IS A DIRECT LINE CLASH BETWEEN THE POWER SUPPLY PILLAR/STREET LIGHT AND FIRE HYDRANT THE FIRE HYDRANT
                                                                                                                                                                                                                                                                                        Ø100                  u-PVC                               90m
                                                                                                                                                                                                                                MAINS                                                                                                                                                IS TO BE LOCATED 600mm OFF THE PROLONGATION OF ANY COMMON BOUNDARY, i.e. 600mm AWAY FROM THE POWER SUPPLY
                                                                                                                                                                                                                                                                                        Ø150                  u-PVC                                -m                                PILLAR/STREET LIGHT.
                                                                                                                                                                                                                                                                                                                  MATERIAL                            LENGTH                 13.     THE CONTRACTOR SHALL DETERMINE ALLOWABLE BEARING CAPACITIES OF THE UNDISTURBED SIDE OF THE TRENCH. DIMENSIONS OF
                                                                                                                                                                                                                                                                       DIAMETER                                                                                                      THE THRUST BLOCK ARE TO BE IN ACCORDANCE WITH SEQ STANDARDS.
                                                                                                                                                                                                                                                                                                             DESIGN      CONST                  DESIGN      CONST
                                                                        1
                                                                       600m²
                                                                                          2
                                                                                         600m²
                                                                                                                3
                                                                                                              600m²
                                                                                                                                                                                                                                SERVICES                                                                                                                                     14.     WATER RETICULATION MAINS SHALL BE CONSTRUCTED WITH PE100 SDR11 PN16.
                                                                                                                                                                                                                                                                                       DN25                  Ø100 PN9                              -m                        15.     ALL CONNECTIONS TO EXISTING / LIVE WATER MAINS TO BE MADE BY CONTRACTOR UNDER URBAN UTILITES SUPERVISION AT
                                                                                                                                                                                                                                                                                                                                                                                     DEVELOPER'S EXPENSE. CONNECTION TO INCLUDE STOP VALVE AS DIRECTED BY SUPERINTENDENT.
                                                                                                                                                                                                                                                                       DIAMETER                                     NUMBER                                                   16.     WATER MAINS SHALL BE TESTED UNDER HYDRAULIC PRESSURE TO A PRESSURE TEST OF 1.2MPa.
                                                                                                                                                                                                                                                                                                                                                                             17.     ALL FASTENERS USED IN THE WORKS SHALL BE STAINLESS STEEL GRADE 316 TO EITHER AS1449 OF AS316 (AMERICAN IRON & STEEL
                                                                                                                                                                                                                                                                                             20Ø                -                                                                    INSTITUTE) OR UNS S31600.
                                                                                                                                                                                                                                METERS
                                                                                      REET                GYMPIE STREET
                                                                                                                                                                                                                                                                                                                                                                             18.     CONTRACTOR TO LIAISE WITH RELEVANT AUTHORITIES FOR THE RELOCATION / PROTECTION OF EXISTING SERVICES. INCLUDING THE
                                                                            GYMPIE ST                                                                                                                                                                                                        25Ø                -
                                                                                                                                                                                                                                                                                                                                                                                     PROVISION FOR EXISTING POWER POLES TO BE HELD DURING TRENCH EXCAVATION, OBTAINING THE NECESSARY APPROVALS FROM
                                                                                                                                                                                                                                                                                             32Ø                -                                                                    ASSOCIATED AUTHORITIES AND APPLICATION FEES.
                                                                                                                                                                                                                                                                                                                                                                             19.     ALL TRENCH EMBEDMENT TO BE 'TYPE C SUPPORT' AS PER SEQ-WAT-1201-1.
                                                                                                                                                                                                                                                                                                                                                                             20.     PE SERVICES SHALL HAVE APPROVED DETECTABLE MARKER TAP LAID ON TOP OF THE BEDDING, EXTENDING FROM THE WATER MAIN
                                                                                                                                                                                                                              ALL ENVIRONMENTAL PROTECTION                                                              ALL WATER AND SEWERAGE CONSTRUCTION                          TO THE METER.
                                                                                                                                                                                                                              MEASURES SHALL BE IMPLEMENTED PRIOR                                                       SHALL COMPLY WITH THE REQUIREMENTS OF THE
                                                                                                                                                                                                                              TO ANY CONSTRUCTION WORK                                                                  QUEENSLAND WORK HEALTH AND SAFETY ACT
                                                                                                                                                                                                                              COMMENCING, INCLUDING CLEARING                                                            2011. CONTACT THE DIVISION OF WORKPLACE              ENVIRONMENTAL CONDITIONS
      NEARMAP                                                                                                                                                                                                                                                                                                           HEALTH AND SAFETY FOR INFORMATION. PHONE
                                                                                LOCALITY PLAN                                                                                                                                 CONSULTANT: RECOR                                                                         1300 362 128                                          VEGETATION PROTECTION
                                                                                                                                                                                                                              CONTACT: EOIN WHITMORE                                                                                                                          A.        TREES LOCATED ALONG THE FOOTPATH SHALL BE, TRANSPLANTED PRIOR TO CONSTRUCTION, OR REPLACED IF
                                                                                         SCALE: 1:1000                                                                                                                        TELEPHONE: 1300 469 707                                                                     DN125 EF TAPPING SADDLES                                      DESTROYED.
                                                                                                                                                                                                                                                                                                                                                                             B.         WHEN WORKING WITHIN 4m OF TREES, RUBBER OR HARDWOOD GIRDLES SHALL BE CONSTRUCTED WITH 1.8m
                                                                                                                                    LIVE WORKS NOTES:                                                                                                                                                                                                                                   BATTENS CLOSELY SPACED AND ARRANGED VERTICALLY FROM GROUND LEVEL. GIRDLES SHALL BE STRAPPED
WATER RETICULATION DRAWING INDEX                                                                                                    1.   ALL WORK ON EXISTING WATER TO BE CARRIED OUT BY THE CONTRACTOR                                                                                                                        EF TRANSITION COUPLERS                                   TO TREES PRIOR TO CONSTRUCTION AND REMAIN UNTIL COMPLETION.
                                                                                                                                         (IN ACCORDANCE WITH AN APPROVED NETWORKS ACCESS PERMIT) UNDER




                                                                                                                                                                                                                                                                         EXISTING DN125 PE MAIN
DWG NO.                        DRAWING TITLE                                                                                             UNITYWATER SUPERVISION, AT THE DEVELOPERS EXPENSE.                                                                                                                                                                                   C.        TREE ROOTS SHALL BE TUNNELED UNDER, RATHER THAN SEVERED. IF ROOTS ARE SEVERED THE DAMAGED
                                                                                                                                    2.   LIVE WORKS CANNOT COMMENCE UNTIL ALL RELEVANT TEST CERTIFICATES                                                                                                                                                                                AREA SHALL BE TREATED WITH A SUITABLE FUNGICIDE. CONTACT RELEVANT COUNCIL ARBORIST FOR FURTHER
C500                           WATER RETICULATION COVER SHEET                                                                                                                                                                                                                                                                            DN25 PE100 WATER SERVICE TO METER              ADVICE.
                                                                                                                                         HAVE BEEN PROVIDED AND ACCEPTED BY UNITYWATER
                                                                                                                                                                                                                                                                                                                                                                             D.         ANY TREE LOPPING REQUIRED SHOULD BE UNDERTAKEN BY AN APPROVED ARBORIST.
C501                           WATER RETICULATION LAYOUT                                                                                                                                                                                                                                                                                                                      SOIL
                                                                                                                                                                                                                                                                                                                                        DN25 PE100 WATER SERVICE TO METER
                                                                                                                                                                                                                                                                                                                                                                              A.        TOPSOIL AND SUBSOIL SHALL BE STOCKPILED SEPARATELY.
                                                                                                                                                                                                                                                                                                                                                                             B.         CARE SHALL BE TAKEN TO PREVENT SEDIMENT FROM ENTERING THE STORMWATER SYSTEM. THIS MAY INVOLVE
                                                                                                                                                                                                                                                                                                                                                                                        PLACING APPROPRIATE SEDIMENT CONTROLS AROUND STOCKPILES.
                    LIVE CONNECTION                                                                                                                                                                                                                                                                                                                                           CREEK CROSSINGS
                                                                                                                                                                                                                                                                                                                                             EF TRANSITION COUPLERS           A.        SILTATION CONTROL MEASURES SHALL BE PLACED DOWNSTREAM OF ANY EXCAVATION WORK.
                               CONNECTION 1
                                                                                                                                                                                                                                                                                                                                                                             B.         APPROPRIATE SEDIMENT CONTROLS SHALL BE USED TO PREVENT SEDIMENT FROM ENTERING THE CREEK.
        STREET                    GYMPIE STREET                                                                                                                                                                                                                                                      UNITY WATER                                                              C.        NO SOIL SHALL BE STOCKPILED WITHIN 5m OF THE CREEK.
        LOCATION                   OPPOSITE LOT 3                                                                                                                                                                                                                                                      EXTENT                          BALL VALVES WITH THREAD               REHABILITATION
        LENGTH             -      TYPE OF MAIN      uPVC 100                                                                                                                                                                                                         LIVE CONNECTION 3 AND 4 DETAIL                                                                           A.        PREDISTURBANCE SOIL PROFILES AND COMPACTION LEVELS SHALL BE REINSTATED.
                                                                                                                                                                                                                                                                                                                                                                             B.         PREDISTURBANCE VEGETATION PATTERNS SHALL BE RESTORED.
        DATE                         DATE                                                                                                                                                                                                                                                             (REFER TO SEQ-WAT-1108-2)
        COMMENCED                    COMPLETED                                                                                                                                                                                                                                                               SCALE: NTS
        SIGNATURE
                                                                                                                                                                                                                                                                                                                                                                              WATER NOTES
                                                                                                                                     EXISTING Ø100 uPVC WATER MAIN                                                                                                  EXISTING Ø200 uPVC WATER MAIN
                                                                                                                                                                                                                                                                                                                                                                              1.     ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CURRENT WSAA WATER SUPPLY CODE OF
                    LIVE CONNECTION                                                                                                          SP-SP-FL TEE                                                                                                                                         SP-SP-FL TEE
                                                                                                                                                                                                                                                                                                                                                                                     AUSTRALIA SPECIFICATIONS AND STANDARD - SOUTH EAST QUEENSLAND SERVICE PROVIDERS EDITION.
                                                                                                                                                                                                                                                                                                                                                                              2.     UNLESS SPECIFIED OTHERWISE ALL MATERIALS AND WORK SHALL COMPLY WITH THE RELEVANT AUSTRALIAN
                               CONNECTION 2                          THRUST BLOCK                                                                 FL-FL SLUICE VALVE                               THRUST BLOCK                                                                                       FL-FL SLUICE VALVE                                                             STANDARDS.
                                                                     FOR uPVC PIPE                                                                                                                 FOR uPVC PIPE                                                                                                                                                              3.     THE CONSTRUCTION OF THE WATER RETICULATION WORK SHOWN ON THIS DRAWING MUST BE SUPERVISED BY AN
        STREET                    BUTLER STREET                                                                                                                     HYDRANT TEE WITH HYDRANT (SEE SEQ-WAT-1205-1)                                                                                               HYDRANT TEE WITH HYDRANT
                                                               (SEE SEQ-WAT-1205-1)                                                                                                                                                                                                                                                                                                  ENGINEER WHO HAS RPEQ REGISTRATION. WORKS NOT COMPLYING WITH THIS REQUIREMENT WILL NOT BE
        LOCATION       ADJACENT DRIVEWAY BUTLER STREET                                                                                                              (WHERE REQUIRED)                                                                                                                            (WHERE REQUIRED)                                                     PERMITTED TO CONNECT TO THE RETICULATION SYSTEM.
        LENGTH                    TYPE OF MAIN                                                                                                                                                                                                                                                                                                                                4.     ALL MATERIALS USED IN THE WORKS SHALL COMPLY WITH THE SEQ-SP'S ACCEPTED PRODUCTS AND MATERIALS
                           -                        uPVC 200
                                                                                                                                                                                                                                                                                                                                                                                     LIST OR BE APPROPRIATELY SHOWN, LISTED AND DEFINED IN THE ENGINEERING SUBMISSION SO THAT THE
        DATE                         DATE
                                                                                    UNITY WATER




                                                                                                                                                                                                               UNITY WATER




                                                                                                                                                                                                                                                                                                                                                                                     ALTERNATIVE PRODUCT OR MATERIAL CAN BE ASSESSED AND IF APPROPRIATE, APPROVED BY THE SEQ-SP.
        COMMENCED                    COMPLETED                                                                                                                                                                                                                                                                                                                                5.     ADOPT LIP OF KERB OR SHOULDER OF ROAD AS PERMANENT LEVEL.
                                                                                      EXTENT




                                                                                                                                                                                                                 EXTENT




                                                                                                                                                                                                                                                                                                                                                                              6.     COVER ON MAINS FROM PERMANENT LEVEL TO BE AS SHOWN IN SEQ-WAT-1200-2.
        SIGNATURE                                                                                                                                                                                                                                                                                                                                                             7.     CONDUITS TO BE INSTALLED IN ACCORDANCE WITH THE STANDARD DRAWINGS.
                                                                                                                                                                                                                                                                                                                                                                              8.     A WATER METER SUPPLIED AT THE DEVELOPER'S COST, IS TO BE INSTALLED AT THE SERVICE POINT OF EACH LOT
                    LIVE CONNECTION                                                                                                                                             Ø100 uPVC WATER                                                                                                                                Ø100 uPVC WATER
                                                                                                                                                                                                                                                                                                                                                                                     IN ACCORDANCE WITH THE STANDARD DRAWING FOR THE SEQ-SP.
                                                                                                                                                                                                                                                                                                                                                                              9.     HYDRANTS TO BE INSTALLED AT THE END OF ALL NEW MAINS WHERE REQUIRED FOR TESTING AND
                       CONNECTION 3 AND 4                                                                                                                                       MAIN                                                                                                                                           MAIN                                                  COMMISSIONING PURPOSES.

        STREET                    GYMPIE STREET                                                                                      FL-SOC DI CONNECTOR                                                                                                                  FL-SOC DI
                                                                     MECHANICAL                                                                                                                      MECHANICAL                                                         CONNECTOR                                                                                                                                                       I, A. Khuzaini Sani certify that:
        LOCATION                   OPPOSITE LOT 1
                                                                       COUPLING                                                                                                                        COUPLING
        LENGTH             -      TYPE OF MAIN      uPVC 100                                                                                                                                                                                                                                                                                                                                                                            1.    This design drawing has been assessed in accordance with
                                                                                                                                                                                                                                                                                                                                                                                                                                              the requirements of the SEQ Code and Unitywater Standards;
        DATE                         DATE
                                                                                                                                                                                                                                                                                                                                                                                                                                        2.    The construction of the works must only be undertaken in
        COMMENCED                    COMPLETED
                                                                                                                                                                                                                                                                                                                                                                                                                                              accordance with this drawing; and
        SIGNATURE                                                                                                                   LIVE CONNECTION 1 DETAIL                                                                                         LIVE CONNECTION 2 DETAIL                                                                                                                                                           3.    No design amendments are permitted either before or during
                                                                                                                                                                                                                                                                                                                                                                                                                                              construction without the approval of Unitywater
                                                                                                                                         (REFER TO SEQ-WAT-1105-1)                                                                                              (REFER TO SEQ-WAT-1105-1)
                                                                                                                                                SCALE: NTS                                                                                                             SCALE: NTS                                                                                                                                                       Signed                      ACR/MAJ 2025-144
NOT FOR CONSTRUCTION
 ----      ----     ----                                                          ----                 ----           North Point    Approved                                                                                                                                                                                                Project Address                                          Title

 ----      ----     ----                                                          ----                 ----
                                                                                                                                     EOIN WHITMORE
                                                                                                                                                                                                                                                                                                                                             12 GYMPIE STREET, TEWANTIN                                WATER RETICULATION COVER SHEET, DRAWING INDEX
                                                                                                                          N
 ----      ----     ----                                                          ----                 ----                          31423     23.02.26                                                                                                                                                                                                                                                AND LOCALITY PLAN
 ----      ----     ----                                                          ----                 ----                          For and on behalf of RECOR Pty Ltd.

 ----      ----     ----                                                          ----                 ----                          Scale                                                                                                ENGINEERING & PROJECT SERVICES                                                                     Client Details                                           Project Name                                                                                 Sheet Size
                                                                                                                                                                                                                                             SUNSHINE COAST | BRISBANE
 B       23.02.26   REISSUED FOR OPW APPROVAL                                     CS                  EW                                                                       NTS                                                          www.recor.au | ABN 89 647 469 707                                                                NOVATO GROUP                                              7 LOT RESIDENTIAL SUBDIVISION                                                                  A1
  A      11.11.25   ISSUED FOR OPW APPROVAL                                       IJ                   AY                                                                                              COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's                                                                            Project Number                                      Drawing Number                            Revision
                                                                                                                                                                                                        client. This drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as

Rev       Date                       Revision Description                   Drawn Check                                                                            DO NOT SCALE, IF IN DOUBT ASK                                              'Issued For Construction' in the revision description.                                                                                                  P0198-25-001 - 01                                    C500                                       B
Log in to download the original file

RFI - P0352-25-003-02-GYMPIE-ST-TEWANTIN.pdf · 23.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.