Att 6 - Existing MCU
Noosa Council documents
4 CONCLUSION
The proposed nightclub use does not conflict with the intent of the Strategic Plan or the
Planning Scheme. It merely seeks a cabaret licence to permit amplified music for
entertainment purposes. Noise emanating from the premises will comply with both the
requirements of the Liquor Act and the Environmental Protection (Noise) Policy 1997, and it
is therefore considered that the use is unlikely to adversely affect the amenity of surrounding
residents and commercial ventures. Furthermore, sufficient carparking exists on site to
accommodate the nightclub use during its proposed hours of operation.
The proposed nightclub use is considered suitable for the location and will complement the
existing restaurant approval.
RECOMMENDATION
With regard to 20841 DA (Irish Murphys Pty Ltd) for a Material Change of Use of Premises
for a Nightclub at 81 Noosa Drive, Noosa Heads described as Lot 1 on RP 206645, Parish of
Weyba, County of March, Council approve the application and grant a Development Permit,
subject to the following conditions:-
Environmental Health
1. Noise control measures to prevent noise nuisance to any residential premises are to be
in accordance with the following requirements -
1.1 General compliance with the Consultant’s Report, Craig Hill Acoustics dated April
2001.
1.2 Amplified music volume not to exceed a maximum sound pressure level of 100 dB(C)
at anytime when measured at 3 metres from any speaker.
1.3 When amplified entertainment is provided with a volume greater than 75 dB(C) when
measured at 3 metres from any speaker, all windows and doors must be closed and
patron access/egress only permitted via the sound lock.
1.4 No external amplified entertainment or external speakers are permitted.
1.5 Upgrading of premises to include the following:
1.5.1 Provision of a sound lock for access/egress of patrons.
1.5.2 Stage area to be enclosed on three sides with speakers facing inwards.
1.5.3 Provision of heavy curtains to all glazed walling.
1.5.4 Provision of ceiling insulation.
1.5.5 Provision of compression limiter to the sound system to enable identification of sound
pressure level and compliance with the requirements of condition 1.2.
1.6 Maintain Noise Management Plan as detailed in Consultant’s Report, Section 10.2, with
Council’s Environmental Health Officers being permitted access to the logbook at
anytime.
1.7 Provision of mechanical ventilation in accordance with the Building Code of Australia
and any requirements of Council’s Building Services Manager, to meet the noise control
measures of closing all doors and windows. Such mechanical ventilation must comply
with Australian Standard 1968.2 - 1991 and have a minimum outdoor air flow rate of 20
litres/second/person at the maximum permitted occupancy rate.