Skip to the record
For the highest quality transcripts.

Council archive · source document

SUPERSEDED Decision Notice - 010.2009.00000879.001 [As Published] · 132009.879

of 10

Text shows just the words. Original shows the document exactly as it was published.

                                                                                        2009/879



36.     Each individual water connection to the water reticulation system shall extend to the property
        boundary and be metered. All fees for the supply of water meters shall be paid to the
        Council.
37.     All water meters must be located outside the property boundary and in an easily assessable
        location to facilitate unhindered reading by Council and/or Council’s contracted water meter
        readers, and not behind fences or locked gates. In this regard approval of the water meter
        configuration and location must be obtained from Council’s Sunshine Coast Water - Capital
        Works Manager prior to lodgement and approval of hydraulic drawings.
38.     Any building or structure within proximity of any underground public utility must have its
        foundations designed so that no surcharge loads are imposed upon such underground
        infrastructure. Foundations must be taken down a minimum of 1.0m below a line of
        influence measured 1.0m in the direction of the foundation from the centreline of the closest
        underground service and along the natural angle of repose of the foundation soil type(s) and
        shall be designed by a registered practicing Geotechnical Engineer.
Site Stability and Earthworks
39.     A Geotechnical Engineer or similar qualified expert shall assess the soil condition on site,
        determine the soil classification, establish whether any measures are required to protect the
        stability of adjoining buildings and/or structures and/or land, and make recommendations on
        the type of foundation system(s) best suited for the proposed development. The
        recommendations of this report shall be incorporated into the design and construction of the
        proposed development.
40.     Earthworks carried out on site shall not affect the structural integrity of any of the existing
        fences or structures that border the development site. Fences that are affected shall be
        replaced prior to the Building Certifier issuing the Certificate of Classification.
Erosion and Sediment Control
41.     Any person acting on this permit shall prevent erosion and sediment export from leaving the
        site. Site control measures such as silt fencing, controlled gravel access to the site and
        controlled disposal of waste, will be necessary.
        In this regard, plans detailing the methods of controlling erosion and sediment in accordance
        with the Healthy Waterways document and fact sheet series titled Controlling Stormwater
        Pollution on your Building Site dated 2006 are required to be submitted with the application
        for a Building Works Permit.

5     REFERRAL AGENCY CONDITIONS

The referral agencies applicable to this application are:

 Referral Trigger            Referral Status     Referral Agency        Referral Address

 Not applicable

6     APPROVED PLANS/DOCUMENTS
The approved plans and / or documents for this development approval are listed in the following
table:
 Drawing Number              Rev.      Plan - Prepared by                             Date
 1                           B         Site Plan – Macchia Pty Ltd                    10 June 2009
 2                           B         Ground Floor Plan – Macchia Pty Ltd            10 June 2009
 3                           B         First Floor Plan – Macchia Pty Ltd             10 June 2009

                                                                                     Page 6 of 10

Used in these records

About this file

File size
69 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED Decision Notice - 010.2009.00000879.001 [As Published].pdf · 69 KB (small file)