Council archive · source document
F0002-AA007595-AAR-09-SMP · MCU14/0102.05
Attached to the e-mail Updated SW management plan MCU14/0102.05.
1.0 Introduction
SPEL Environmental has been requested by Noosa Shire Council to prepare a report for the SPEL Puraceptor to
demonstrate the overall compliance of the Puraceptor and its performance in removing hydrocarbons from
stormwater, compliant with Council requirements. And in addition achieve the capture of a large spill that may
occur as a result of tanker unloading and retain it as a holding tank function via the auto-closure device. The
SPEL Puraceptor is sized to collect the oily runoff from all the high risk area on site and treat it to less than 5 ppm
hydrocarbon concentration and discharge to stormwater. The aerial view of the site is shown below:
The site is a proposed Service Station and Commercial Centre located in 139 Eumundi Noosa Road Eumundi, QLD
which is about 120 km north of Brisbane and under Noosa Shire Council. The undercanopy area of the Service Station
will be considered as high risk and will therefore be treated by the Puraceptor.
The proposed SPEL Puraceptor for this siteis a P.070.S.C1.2C which has a spill capacity of 12,400 Litres.
HEAD OFFICE POSTAL EMAIL ABN spel.com.au
100 Silverwater Road PO BOX 7138 [email protected] 83 151 832 629
Silverwater NSW 2128 Silverwater NSW 2128
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
F0002-AA007595-AAR-09-SMP.PDFRelated documentApplication case desk ↗
About this file
- File size
- 9.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.