Council archive · source document
Reference Document - EXE25 0035 (As Published) · EXE25/0035
CL
5665 720 COS 3500 3500 2000 3500 4000 6200
STEPFREE THRESHOLD TO
CL 2960 1510 1600 2115 6000
4500 SHOWER & DOORWAY. WALL
REINFORCEMENT AS PER LIVABLE
HOUSING GUIDELINES.
2 BIN STORE /
1500
1500
1500
EXISTING REVETMENT WALL LAWN
LETTERBOX
A500
W W W W
08 9 W 11 12
800
10
BEDROOM 3 BEDROOM 4 7160
ENSUITE 2 WIR
2785
1200
W
3500
900
3140
07 1500 500 910 500 MEDIA
D.12 D.22
7135 COS
BATHROOM 1
5890 COS
D.01
DRIVEWAY
6200
GARAGE
D.10
BEDROOM 2 FFL 2.700
D.11 D.13 D.14
1440 COS
1200
W D.09 D.07 STEPFREE
3000
D.08 THRESHOLD
06
1
1190
990
WINE CELLAR STORAGE
1170
A600 POWDER 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
ENTRY
NOOK
800
D.20
OUTDOOR KITCHEN / BBQ W 1
D.06
2000
05 FFL 2.700 D.02 ENTRY
LINE OF STOREY ABOVE
A500
FFL 2.650
4610 COS
1 DINING
430
4735 COS
A501 D.05
6000
FEATURE FIREPLACE
LAWN OUTDOOR DINING PLANTER
LIVING 600
0
8850 COS
1100
1400
700
6300
D.03 W
1200
KITCHEN LAWN
13
NEW FEATURE TREE
FFL 2.050
1520
1 POOL
OUTDOOR
3800
FFL 0.900 SUNKEN
4100
DRY WM
3825
A601 LOUNGE
4250
W LAUNDRY
04 D.21 CHUTE
1200
5500
D.15
1360 1530 1360
1160 COS
BUTLERS PANTRY LAUNDRY W W W
714
02 01 5
600
1060 300
14
700 COS
2705
POOL
STORE
W D.04
DAY BED
1675
WALL MOUNTED 03
2175
CLOTHESLINE
1500
FFL 2.650 1 2
2120
FFL 2.650
A602 A501
GRAVEL GARDEN
2100 1655 3025 2250 1965 COS 720
0 1 2 3 4m
2045 6985 COS 5900 1:100
Issue Description Date Client Project Title Drawing No. Issue
A FOR INFORMATION 18.06.2025 SIDESEA DEVELOPMENT PTY LTD 40 SEAMOUNT QUAY, GROUND FLOOR PLAN A100 B
SA
Sophie Arnett B FOR INFORMATION 07.07.2025 NOOSA WATERS
Architect Scale Drawing Size
Eumundi QLD 4562
QLD 4566 COUNCIL ANNOTATION:
PH 0402 669 145
1 : 100 A3
Exemption Certificate EXE25/0035 only
[email protected]
ABN 98 350 285 008
NOOSA COUNCIL relates to the dwelling within the Project No. Drawn By
REFERENCE DOCUMENT Flooding and Inundation Area as 2506 SA
ARCHITECTURE I INTERIORS EXE25/0035 29 AUG 2025 included within the Flood Hazard Dimensioned Drawings to take precedence over scaling. Contractor to
verify all dimensions on site before construction. All inconsistencies to
Overlay Code mapping. be reported to the Architect immediately. This drawing and its contents
remain the copyright of Sophie Arnett ©
Document Set ID: 24059467
Version: 1, Version Date: 26/08/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records