Skip to the record
The definitive source for everything Noosa Council.

Original source · versioned page text

Att 9 - Geotech and PASS report

Attached to the e-mail Council Road Upgrade, Attachments inc Waste Mgmt Plan & Geotech (Email 2 of 3).MCU17/0054.

of 40

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

               www.biotrack.com.au
               781 Mt Glorious Rd Highvale 4520       Biotrack Certificate of Analysis
                                                      Signatory:                      Ph:+617 3289 7179 ABN 91 056 237 275


Test Code/Name              [1] FIELD SCREEN SUITE
Lab Reference (LR)          270417.415                Client Name         Douglas Partners Pty Ltd
SampleID                    All Samples               Client Contact      Brett Egen
                                                      Project Name        Hilton Tce Tewantin
Report Date                 5/05/2017                 Job Number          90151
Sample Received Date        24/04/2017                Order Number
Sample Disposal Date        26/06/2017                Chain of Custody
Sample Packaging            Plastic Bag               Client Email        [email protected]
Temperature                 Ambient                   Client Address      439 Montague Rd West End Brisbane Queensland 4101


Analytical Method: Test Methodology for pH_f and pH_fox as per QASSIT 2004 Laboratory Methods. Indications based on pH data only.
RATE: 0 = No Reaction 2=Moderate 3=High 4=Very High (steam evolved).
TEMP: Surface temperature rise ( C) oxidised sample at 5 minutes - cooling may occur for fast reaction.


 S# SampleID                       pH_f      pH_Fox   Change       Rate   Indication
  1 BH1 0-250                       6.8        6.4     -0.4         4     no TAA & low TPA & low sulphide
  2 BH1 250-500                     8.2        6.5     -1.7         0     no TAA & low TPA
  3 BH1 500-750                     8.1        7.4     -0.7         0     no TAA & no TPA & low sulphide
  4 BH1 750-1000                    7.9        6.7     -1.2         0     no TAA & no TPA
  5 BH1 1000-1250                   6.7        2.5     -4.2         4     no TAA & moderate TPA & high sulphide/low buffer
  6 BH1 1250-1500                   6.8        2.8     -4.0         4     no TAA & moderate TPA & high sulphide/low buffer
  7 BH1 1500-1750                   7.1        2.0     -5.1         4     no TAA & high TPA & high sulphide/low buffer
  8 BH1 1750-2000                   7.2        2.1     -5.1         4     no TAA & high TPA & high sulphide/low buffer
  9 BH2 0-250                       7.5        6.5     -1.0         1     no TAA & low TPA
 10 BH2 250-500                     7.8        6.0     -1.8         1     no TAA & low TPA
 11 BH2 500-750                     8.0        6.2     -1.8         1     no TAA & low TPA
 12 BH2 750-1000                    8.0        6.4     -1.6         1     no TAA & low TPA
 13 BH2 1000-1250                   8.1        6.5     -1.6         1     no TAA & low TPA
 14 BH2 1250-1500                   7.7        6.3     -1.4         4     no TAA & low TPA
 15 BH2 1500-1750                   7.6        6.5     -1.1         4     no TAA & low TPA
 16 BH2 1750-2000                   7.6        6.2     -1.4         4     no TAA & low TPA
 17 BH3 0-250                       6.6        2.8     -3.8         2     no TAA & moderate TPA & high sulphide/low buffer
 18 BH3 250-500                     7.9        5.6     -2.3         2     no TAA & low TPA & sulphide possible
 19 BH3 500-750                     7.6        3.8     -3.8         2     no TAA & high sulphide/low buffer
 20 BH3 750-1000                    6.5        3.0     -3.5         1     low TAA & moderate TPA & high sulphide/low buffer
 21 BH3 1000-1250                   7.5        3.4     -4.1         4     no TAA & moderate TPA & high sulphide/low buffer
 22 BH3 1250-1500                   6.6        2.4     -4.2         3     no TAA & high TPA & high sulphide/low buffer
 23 BH3 1500-1750                   7.4        3.0     -4.4         4     no TAA & moderate TPA & high sulphide/low buffer
 24 BH3 1750-2000                   7.5        2.4     -5.1         4     no TAA & high TPA & high sulphide/low buffer
 25 BH4 0-250                       4.9        2.6     -2.3         4     low TAA & moderate TPA & sulphide possible
 26 BH4 250-500                     5.0        2.9     -2.1         0     low TAA & moderate TPA & sulphide possible
 27 BH4 500-750                     5.8        3.1     -2.7         1     low TAA & moderate TPA & sulphide possible
 28 BH4 750-1000                    7.4        3.6     -3.8         4     no TAA & high sulphide/low buffer
 29 BH4 1000-1250                   7.3        4.3     -3.0         4     no TAA & sulphide possible
 30 BH4 1250-1500                   6.8        2.0     -4.8         3     no TAA & high TPA & high sulphide/low buffer
 31 BH4 1500-1750                   6.8        3.3     -3.5         4     no TAA & moderate TPA & high sulphide/low buffer
 32 BH4 1750-2000                   6.5        2.2     -4.3         4     low TAA & high TPA & high sulphide/low buffer




                                                                                                                                    Page 2
Log in to download the original file

Att 9 - Geotech and PASS report.pdf · 2.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.