Original source · versioned page text
Att 9 - Geotech and PASS report
Attached to the e-mail Council Road Upgrade, Attachments inc Waste Mgmt Plan & Geotech (Email 2 of 3).MCU17/0054.
www.biotrack.com.au
781 Mt Glorious Rd Highvale 4520 Biotrack Certificate of Analysis
Signatory: Ph:+617 3289 7179 ABN 91 056 237 275
Test Code/Name [1] FIELD SCREEN SUITE
Lab Reference (LR) 270417.415 Client Name Douglas Partners Pty Ltd
SampleID All Samples Client Contact Brett Egen
Project Name Hilton Tce Tewantin
Report Date 5/05/2017 Job Number 90151
Sample Received Date 24/04/2017 Order Number
Sample Disposal Date 26/06/2017 Chain of Custody
Sample Packaging Plastic Bag Client Email [email protected]
Temperature Ambient Client Address 439 Montague Rd West End Brisbane Queensland 4101
Analytical Method: Test Methodology for pH_f and pH_fox as per QASSIT 2004 Laboratory Methods. Indications based on pH data only.
RATE: 0 = No Reaction 2=Moderate 3=High 4=Very High (steam evolved).
TEMP: Surface temperature rise ( C) oxidised sample at 5 minutes - cooling may occur for fast reaction.
S# SampleID pH_f pH_Fox Change Rate Indication
1 BH1 0-250 6.8 6.4 -0.4 4 no TAA & low TPA & low sulphide
2 BH1 250-500 8.2 6.5 -1.7 0 no TAA & low TPA
3 BH1 500-750 8.1 7.4 -0.7 0 no TAA & no TPA & low sulphide
4 BH1 750-1000 7.9 6.7 -1.2 0 no TAA & no TPA
5 BH1 1000-1250 6.7 2.5 -4.2 4 no TAA & moderate TPA & high sulphide/low buffer
6 BH1 1250-1500 6.8 2.8 -4.0 4 no TAA & moderate TPA & high sulphide/low buffer
7 BH1 1500-1750 7.1 2.0 -5.1 4 no TAA & high TPA & high sulphide/low buffer
8 BH1 1750-2000 7.2 2.1 -5.1 4 no TAA & high TPA & high sulphide/low buffer
9 BH2 0-250 7.5 6.5 -1.0 1 no TAA & low TPA
10 BH2 250-500 7.8 6.0 -1.8 1 no TAA & low TPA
11 BH2 500-750 8.0 6.2 -1.8 1 no TAA & low TPA
12 BH2 750-1000 8.0 6.4 -1.6 1 no TAA & low TPA
13 BH2 1000-1250 8.1 6.5 -1.6 1 no TAA & low TPA
14 BH2 1250-1500 7.7 6.3 -1.4 4 no TAA & low TPA
15 BH2 1500-1750 7.6 6.5 -1.1 4 no TAA & low TPA
16 BH2 1750-2000 7.6 6.2 -1.4 4 no TAA & low TPA
17 BH3 0-250 6.6 2.8 -3.8 2 no TAA & moderate TPA & high sulphide/low buffer
18 BH3 250-500 7.9 5.6 -2.3 2 no TAA & low TPA & sulphide possible
19 BH3 500-750 7.6 3.8 -3.8 2 no TAA & high sulphide/low buffer
20 BH3 750-1000 6.5 3.0 -3.5 1 low TAA & moderate TPA & high sulphide/low buffer
21 BH3 1000-1250 7.5 3.4 -4.1 4 no TAA & moderate TPA & high sulphide/low buffer
22 BH3 1250-1500 6.6 2.4 -4.2 3 no TAA & high TPA & high sulphide/low buffer
23 BH3 1500-1750 7.4 3.0 -4.4 4 no TAA & moderate TPA & high sulphide/low buffer
24 BH3 1750-2000 7.5 2.4 -5.1 4 no TAA & high TPA & high sulphide/low buffer
25 BH4 0-250 4.9 2.6 -2.3 4 low TAA & moderate TPA & sulphide possible
26 BH4 250-500 5.0 2.9 -2.1 0 low TAA & moderate TPA & sulphide possible
27 BH4 500-750 5.8 3.1 -2.7 1 low TAA & moderate TPA & sulphide possible
28 BH4 750-1000 7.4 3.6 -3.8 4 no TAA & high sulphide/low buffer
29 BH4 1000-1250 7.3 4.3 -3.0 4 no TAA & sulphide possible
30 BH4 1250-1500 6.8 2.0 -4.8 3 no TAA & high TPA & high sulphide/low buffer
31 BH4 1500-1750 6.8 3.3 -3.5 4 no TAA & moderate TPA & high sulphide/low buffer
32 BH4 1750-2000 6.5 2.2 -4.3 4 low TAA & high TPA & high sulphide/low buffer
Page 2