OPW16/0094 - Approved Plans
Plans and drawings: the text below has words only, no drawings.
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
OPW16/0094 8 JUNE 2016
APPROVED PLAN
NOOSA COUNCIL
-
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
1.
1.73
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
DRAWING SIZE - Al
EXISTING VEGETATION TO
REAR OF SITE TO BE KEPT
TO ENSURE SLOPE STABILITY.
INDICATES CONTIGUOUS CONCRETE PILING, DESIGN AND
INSTALLATION BY OTHERS. MINIMUM VIBRATION
TECHNIQUES TO BE USED FOR INSTALLATION, VIBRATION
CONTROL AND MANAGEMENT BY PILING CONTRACTOR.
BUILDER TO CONFIRM EXTENT REQUIRED TO SATISFY
CRITICAL DEPTH LINE PROTECTION OF NEIGHBOURING
STRUCTURES. REFER DETAIL.
353.000)
NEIGHBOURING
HATCHING INDICATES 40° BATTERED
BANK WITH CONCRETE SPRAYED
FACE. REFER DETAIL BELOW.
SITE PLAN — SITE BENCHING & RETAINING WALLS
SoS
%
or,
2
Lo % |
a, B
oe.
7 > |
2
| Scale 1: 100
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER /CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR TO
COMMENCING WORKS.
Ground /
pad level
UNSTABLE
THIS FOOTING IS FOUNDED
BELOW CRITICAL DEPTH
LINE AND IS STABLE. STABLE
THIS FOOTING WITHOUT
fr PIERS IS FOUNDED
ABOVE CRITICAL DEPTH
LINE AND IS UNSTABLE.
LINE OF PROPOSED
PIERS OR UNDERPINNING FOUNDED
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED 10 SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE. Horizontal
CRITICAL DEPTH LINE
173 —— EXCAVATION OR OTHER
ST TRENCH.
30 Degrees
Koo
NOTE:
THIS DETAIL ALSO APPLIES TO EXISTING
FOUNDATIONS ON NEIGHBOURING
PROPERTIES. SHEET PILING MUST BE
INSTALLED WHERE EXISTING FOOTINGS WILL
BE FOUNDED ABOVE ANY EXCAVATION
CRITICAL DEPTH LINE
x
HATCHING INDICATES CUT BENCH
AT RL. 48.800.
a S J
/ Lf
Lot 20 /
KP 48115 PROPOSED
- GARAGE.“
eo FFL 46.000
ws cS
wn
4 » $5.84
190 BLOCK RETAINING WALL
e
=
Q
-
Sb'Sp
HOUSE
PROPOSED UNIT
DEVELOPMENT
N.
/ . 44.50 |
UNIT 2.
EXTENT OF PILES TO BE
DETERMINED IN ACCORDANCE WITH
CRITICAL DEPTH LINE PROTECTION
GROUND LEVEL
SATURATE GROUND ADJACENT EXCAVATION
FOR A MINIMUM OF 24 HOURS PRIOR TO
WORKS COMMENCING.
NEIGHBOURING
HOUSE
SPRAYED 25MPA CONCRETE
FACING SL72 MESH MIDDLE
EXCAVATED LEVEL
TYPICAL SECTION ~ SPRAYED CONCRETE FACED EMBANKMENT
‘la
ne
RD
(28
$
; 28
|
99'v
Ce'Sr
69Gb
we Es —————3/s
CONCRETE POOP? ATH go'Sv
BR
oO}
nN
Nm
| as
bo yfe 8
e oo
ko
Pad
J
||C
! x
8B ui
| |} >
~~ 1 n
om I
Pad
NOOSA COUNCIL
APPROVED PLAN
OPW16/0094 8 JUNE 2016
a
2
=
S9 5 A
yo 9
~*~ © 5
45.48
Power Pble
‘—o
SW/EX &
GK
2.08
oe
mn
FALL
L210}
S/EX
sw/EX ——————
LEGEND
_—_ INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF FALL UP
OR DOWN AS INDICATED
INDICATES PROPOSED FINISHED
SURFACE LEVELS - PAVEMENT
INDICATES PROPOSED FINISHED
SURFACE LEVELS — LANDSCAPING
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES EXISTING STORMWATER
DRAIN /MAIN.
CONSTRUCTION NOTES.
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25% LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED 10 SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS 10 BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 10
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
PRIOR TO CONSTRUCTION COMMENCING.
Checked:
RPEQ 5835
S Richardson
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated drawings are
copyright and are not to be used or reproduced without the written permission of
‘SCG Consulting Engineers.
AMEND. DATE
DESCRIPTION APPR.
AMENDMENTS
FOR DEVELOPMENT APPROVAL
DEBUILD T/A
&ce)<2r sulting ENGINEERS
STRUCTURAL eCIVILeGEOTECHNICAL
ABN 40 098 481 899
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Ph (07) 5455 5604 Fax (07) 5455 5696
Title:
OPERATIONAL WORKS:
SITE BENCHING & RETAINING WALLS
Project
9 DUKE STREET
SUNSHINE BEACH
Date: Scale: Drawn:
March 16 AS NOTED
ms N° 25464 -OWS Rev