Table 1.2.2: Environmental emissions
 Performance outcomes                                           Acceptable outcomes                                           Response
 Noise
 Accommodation activities
 PO23 Development involving an accommodation activity or        AO23.1 A noise barrier or earth mound is provided which is    Not applicable
 land for a future accommodation activity minimises noise       designed, sited and constructed:                              The proposed cabins are setback more than 280m from the
 intrusion from a state-controlled road or type 1 multi-modal       1. to meet the following external noise criteria at all   state controlled road. Given the setback distance it is
 corridor in habitable rooms.                                          facades of the building envelope:                      considered that a noise barrier or earth mound is not
                                                                                                                              required to provide acoustic attenuation for road traffic
                                                                                           a.   ≤ 60 dB(A) L10 (18 hour)      noise.
                                                                                                façade corrected (measured
                                                                                                L90 (8 hour) free field
                                                                                                between 10pm and 6am
                                                                                                ≤ 40 dB(A))
                                                                                           b.   ≤ 63 dB(A) L10 (18 hour)
                                                                                                façade corrected (measured
                                                                                                L90 (8 hour) free field
                                                                                                between 10pm and 6am
                                                                                                > 40 dB(A))
                                                                   2.   in accordance with chapter 7 integrated noise
                                                                        barrier design of the Transport Noise Management
                                                                        Code of Practice – Volume 1 Road Traffic Noise,
                                                                        Department of Transport and Main Roads, 2013.

                                                                Note: To demonstrate compliance with the acceptable
State Development Assessment Provisions – version 2.1
State code 1: Development in a state-controlled road environment                                                                                                Page 12 of 24

Used in these records

About this file

File size
278 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SDAP Code Assessment.pdf · 278 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.