ORDINARY MEETING AGENDA 17 AUGUST 2017
Water Reuse
45. Detail design plans submitted with the Operational Works Application must
demonstrate how waters will be reticulated from the rainwater storage tank to
reuse areas with a minimum water use of 342KL per annum.
46. A suitable backflow prevention device must be installed on water reuse facilities
to protect the potable water within the reticulated water supply in accordance
with AS/NZS 3500:2003 Plumbing and Drainage.
WASTE MANAGEMENT
Waste Storage
47. The development must provide waste storage and disposal facilities in
accordance with Planning Scheme Policy 9, Waste Management, including an
external imperviously paved area correctly sized for all refuse and recycling
containers and suitably screened from public places and neighbouring
properties.
The waste management facilities should ensure recyclables bins are
appropriately sited and accessible, and/or provided with their own waste shute,
to ensure recyclable waste is not placed in the general waste shute.
48. The site must be provided with a bin wash area with a cold-water tap, hose and
drain outlet connected to sewer, via a bucket trap. The drain outlet is to be
designed to prevent storm water entry to the sewerage system which can be
achieved by a bunded area, with a nib wall height of 100mm maximum,
enclosing a wash area of 700mm x 700mm minimum (max 0.7m²).
Alternatively, the waste area can be roofed, or any other appropriate design
approved by Council.
Building Demolition/Removal/Relocation
49. A Waste Management Plan (construction and demolition) must be submitted
and approved by Council’s Environmental Health Officer prior to issue of a
development permit for operational works for demolition, removal or relocation
of any building other than a shed.
The purpose of the Waste Management Plan is to facilitate the segregation of
waste for the effective reuse and recycling of such materials. Segregated
wastes attract significantly reduced disposal fees at the landfill with some items
free. Higher gate fees are charged for mixed waste.
Waste Management Plans (construction and demolition) are required to be
submitted in accordance with Planning Scheme Policy 11, Waste Management
Plans.
Waste storage areas must provide adequate separation of all reusable,
recyclable and waste materials. These must be located so that they are
convenient and safe to use.
The Plan must contain the following information:
The site area for the storage and separation of waste is to be shown on
the plan drawings accompanying the application.
A waste management table as indicated below is to be completed
showing how waste material is to be segregated - recycled – reused or
disposed.