SEC Constructions_P3_S1_Secondary Residence Plan · OPW20/0197

of 10

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                                                                                    SHEET NUMBER SHEET TITLE
                                                                                                                                                          1        Title Page
                                                                                                                                                          2         Site plan
                                                                                                                                                          3        Floor Plan
                                                                                                                                                          4        Elevations
                                                                                                                                                          5        Section A
                                                                                                                                                          6      Sections B & C
                                                                                                                                                          7       Sub-Floor &
                                                                                                                                                                Bracing Layouts
                                                                                                                                                          8      Bracing Details
                                                                                                                                                          9          Notes
                       Eastern View                                                                                                                      10        Work Place
                1                                                                                                                                                Health & Safety
                                                                                                                                                                     Notes




               Southern View
         3


                                                                                                                                                                 Northern View
                                                                                                                                                       2

                                                                                                                                                      Any Alterations to the design or substitution of structural members
                                                                                                                                                        from approved design plans with out the written consent from
                                                                                                                                                                   Steven Horn Accolade Building Designs
                                                                                                                                                                 will void any responsibilities we have for the
                                                                                                                                                              structural integrity or performance of the building
             Western View                                                                                                                           THESE DRAWING ARE SUBJECT TO COPYRIGHT NO PART MAY BE
     4                                                                                       DISPLAY ONLY
                                                                                                                                                   COPIED OR REPRODUCED OTHER THAN FOR THE PURPOSE OF THIS
                                                                                                                                                   CONSTRUCTION WITHOUT WRITTEN CONSENT FROM STEVEN HORN,
                                                                                                                                                              ACCOLADE BUILDING DESIGN & DRAFTING
Client: Ken & Sorelle Christensen       Address: 69 Maple St Cooroy          Noosa Shire Council                                            Mobile: 0407 693 018                        Date     9/04/2020 8:46:11 AM
                                                                                                       ACCOLADE Building Designs                                                       Drawn by: S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605         Site Area : 1018 m²     Wind Classification N3                                  Proprietor: Steven Horn   Email: [email protected] Project Number
                                                                                                                                                                                                                      0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                            QBCC Lic. 54806        Issue Date   09 - APRIL - 20                          Sheet No. 1          of   10
Full text of the other 9 pages

Page 2

                Downpipe Locations Shown are Suggested Positions only
   Final Positions are to be Determined by Plumber, or Roofing Contractor & Builder




                                                                                                        ET
                                                                                                      RE
                                                                                                    ST
                                                                                                                                       Driveway




                                                                                          E
                                                                                        PL
                                                                                       A
                                                                                      M
                                                                                                           "
                                                                                                         00
                                                                                                    0'
                                                                                                  °0
                                                                                                47
                                                                                                                4m




                                                                                                                                                                                        31
                                                                                                                                                             00




                                                                                                                                                                                           44
                                                                                                            . 12                                           30




                                                                                                                                                                                              3
                                                                                                         2 0




                                                                                                                                                                                                               13
                                                                                                                                                                                                                  7°
                                                                                                                                                                                                                        01




                                                                                                                                                                                                                                                                                 ed
                                                                                                                                                                                                                                                                               sh
                                                                                                                                                                                                                        '0




                                                                                                                                                                                                                                                                           oli
                                                                                                                                                                                                      50




                                                                                                                                                                                                                                                                         em
                                                                                                                                                                                                                          0"
                                                                                                                                                                                 Driveway




                                                                                                                                                                                                        . 65




                                                                                                                                                                                                                                                                      dD
                                                                                                                                                                                                                                                                    he
                                                                                                                                                                                                            2m




                                                                                                                                                                                                                                                                     S
                                                                                                                                                                                                                                                                                        NORTH




                                                                                                                                                                                                                                                                  ng
                                                                                                                                                                                                                                                            isti
                                                                                                                                                                                                                                                          Ex
                                                                                                                                                                                              4                                    0
                                                                                                                                                                                                                                50
                                                                                                                                                                                                                           00
                                                                                                                                                                                                                         30
                                                                                                                                                                                                2
                                                                                                                                                                                                  5
                                                                                                                                  Existing Residence                                           04
                                                                                                                                                                                            10                                         Pro
                                                                                                                                                                                                                                          po s
                                                                                                                                                                                                                                              ed
                                                                                                                                                                                                                                                   Ca
                                                                                                                                                                                                                                                        rp o
                                                                                                                                                       Existing Garage                                                                                       rt
                                                                                                                                                                                                                                                                                      Existing Shed Demolished
                                                                                                                                                                                                      7055

                                                                                                                                                                                                                                                                       40
                                                                                                                                                                                                                                                                     50




                                                                                                                                                                                36
                                                                                                                                                                                  45
                                                                                                                                                                                                                                                                                                                                                  4




                                                                                                                                     31
                                                                                                                                                                                                                                                                                                                                              1




                                                                                                                                       7°
                                                                                                                                            01




                                                                                                                                                                   36




                                                                                                                                                                                                                                                                                                                 Min
                                                                                                                                                                                                                           e
                                                                                                                                            '0




                                                                                                                                                                     89




                                                                                                                                                                                                                        enc
                                                                                                                                 50



                                                                                                                                              0"
                                                                                                                                   . 65




                                                                                                                                                                                                                    esid




                                                                                                                                                                                                                                                                                                                      150 0
                                                                                                                                       2m




                                                                                                                                                                                                                 nd R




                                                                                                                                                                                                                                                                                                                          t o Ou
                                                                                                                                                                                                                 e co
                                                                                                                                                                                                             ed S




                                                                                                                                                                                                                                                                                                                             ts ide
                                                                                                                                                                                                          pos




                                                                                                                                                                                                                                                                                       Min.




                                                                                                                                                                                                                                                                                                                               edge
                                                                                                                                                                                                         Pro




                                                                                                                                                                                                                                                                                         7001
                                                                                                                                                                            4




                                                                                                                                                                                                                                                                                                                                   of fo
                                                                                                                                                                   4




                                                                                                                                                                                                                                                                                            to Po




                                                                                                                                                                                                                                                                                                                                      oting
                                                                                                                                                                                                                                                                                                sts
                                                                                                                                                                                                                                                                          we   r
                                                                                                                                                                                                                                                         tre       o f Se
                                                                                                                                                                                                                                                    C en


                                                                                                                                                                                                                                 3




                                                                                                                                                                                                                                                                  10
                                                                                                                                                                                                    15                                    4                                                                             0"




                                                                                                                                                                                                                                                                     41
                                                                                                                                                                                                  19                                                                                                                  '0




                                                                                                                                                                                                                                                                        3
                                                                                                                                                                                                                                                                                                                  0
                                                                                                                                                                                                                                                                                                           7   °0
  Real Property Description                                                                                                                                                                                                                                                                           22                       4m
                                                                                                                                                                                                                                                                                                                          .0 12
                                                                                                                                                                                                                                                                                                                      2
       Lot No. 4 on C5605
       Locality: Cooroy                                                                                                            Site Plan
       Address: 69 Maple St.
       Site Area: 1018 m²
                                                                                                                            1       1 : 200



Client: Ken & Sorelle Christensen                                        Address: 69 Maple St Cooroy                 Noosa Shire Council                                                                                                                                 Mobile: 0407 693 018        Date     9/04/2020 8:46:11 AM
                                                                                                                                                             ACCOLADE Building Designs                                                                                                               Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                              Site Area : 1018 m²                  Wind Classification N3                                                              Proprietor: Steven Horn                                                                 Email: [email protected]
                                                                                                                                                                                                                                                                                                                                                  Project Number                0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                                        QBSA Lic. 54806                                                                        Issue Date:                         09 - APRIL - 20                             Scale   1 : 200 Sheet No. 2    of 10

Page 3

                                                                                                                                                                                                                                                         100
                                                                                      2980                                                                        6990                                                            1050
                                                                                                           70                                           90                                                           70
                                                                                                                            2560                                                3600                               600
                                                                           70                                     70         2170                                                                   70                                100




                                                                                                                                                                                                                                                                                            30 0
                                                                                     2700                600                                                              2770                                 1430               1050                                                                                                                                                               Window Schedule
                                                                                                                                                  70




                                                                                                                                                                                                                                                                                                  10 0
                                                                                                                             1900                                       3060                                                                              2879
                                                                                                                                                                                                                                116                                                                                                                                  Mark Height Width      Comments        Location           Lintel            Jamb Studs
                                                                                                                                                                                                                                                                                                                                                                      W1   600     1500      Alum Slider     Bed 2      90x35 Smart LVL 14             2
                                                                                                                                                                                                                                                                                                                                                                      W2   900     1500      Alum Slider   Bathroom     90x35 Smart LVL 14             2




                                                                                                                                                                                                                                                                                                       25 5
                                                                                                                                                                                                                                                               R B2




                                                                                                                                                                                                                                                                                          B ou
                                                                                                                                                                                                                                                                                                                                                                      W3   900     2400      Alum Slider     Bed 1      170x35 Smart LVL 14            2




                                                                                                                                                                                                                                                                                                        0

                                                                                                                                                                                                                                                                                                                54 0
                                                                                                                                                                                                                                                                                              nd ar
                                                                                                                                                                                                                                                                                                                                                                      W4   1800     450   Alum Double Hung   Living     90x35 Smart LVL 14             2




                                                                                                                                                                                                                                                                                                                0 10 0
                                                                                                                                                                                                                                                                                                   y
                                                                                                                                                                                                                                                                                                                                                                      W5   1800     450   Alum Double Hung   Living     90x35 Smart LVL 14             2
                                                                                                                                                                                                                                                                                                                                                                      W6   1200    1800      Alum Slider    Kitchen     130x35 Smart LVL 14            2
                                                                                                                                                                                                                                                                                                                                                                      W7   900      600   Alum Double Hung Kitchen      90x35 Smart LVL 14             2
                                                                                                                                                                                                                                    Concrete Slab
                                                                                                                                                                                                                                                                                                                                                                      W8   900      600   Alum Double Hung Kitchen      90x35 Smart LVL 14             2




                                                                                                                                                                                                                3634




                                                                                                                                                                                                                                                                                                                     25 5
                                                                                                                                                                                                                                                                                                                                                                      W9   1200    1800      Alum Slider     Bed 2      130x35 Smart LVL 14            2
                                                                                                                                                                                                                                                                      R B3




                                                                                                                                                                                                                                                                                                                       0
                                                                                                                                                                                                                                   Ramp Slope 1 in 14
                                                                                                                                                                                                                                                                                                 XB




                                                                                                                                                                                        1010 100




                                                                                                                                                                                                                                                                                                                               10 0
                                                                                                                                       W2                                        W3
   450




                                                                                                                                                                                                                                                                                                                                  30 0
                                                                                                                                                                                                                                                                                    top
                                                                                                                                                                                                                                                                                el S
                         70




                                                                                                                                                                                                                                                                                                                                                70
                                                                                                                                                                                                                                                                             Whe B2                                                                                                                    Door Schedule



                                                                                                                900 wide




                                                                                                                                                                                                                                                                                                                                         1000
                                                                                                                  SHR
                                          1060
                  1270

                              1200




                                                                                                                                                                                                                                                                                R




                                                                                                                                                                                                                                                                                                                         137
                                                                                      W1                                                                                                                                                                                            XB
                                                                                                              NICHE                                                                                                              Timber                                                                                                                              Mark Height Width      Comments        Location           Lintel            Jamb Studs




                                                                                                                                                                                                                                                                                                                           ° 01



                                                                                                                                                                                                                                                                                                                                                70
                                     70




                                                                                                                                                                                                                                                                                                              50.6
             70




                                                                                                                                                  920 C/S




                                                                                                                                                                                                                                                                                                                                                            3040
                                                                                                                                  Bath
                                                       3000




                                                                                                                                                                                                                                                                                                                                                                      D1   2040    920        Entry Door    ENT/Foyer     90x35 Smart LVL 14           2




                                                                                                                                                                                                                                                                                                                                                     3140
                                                                                                                                                                                Bed 1




                                                                                                                                                                                                                                                                                                                               ' 00"
                                                                                                                                                                                                                                                                                                               52 m
                                                                                                                           EX                                                    CF                                                                                                       C                                                                           D2   2100    3600      Alum Stacker     Living     2/200x35 Smart LVL 14         3




                                                                                                                                                                                                                       Robe
                                          1640
                              1500




                                                                                                                                                                                                                                                                                                                                         1930
                                                                                                          Store



                                                                                                                                                                        S
                                                                                                                                                                                                                                                                                          6
                  2800




                                                                    W9




                                                                                     Study
                  70




                                                                                                                                                                                                                                                                                                                                                70



                                                                                                                                                                                                                                                                                                                                                               100
                                                                                      CF                                                                                                                                                                                                                             100
                                             1220 70




                                                                                                    S                                       920                  920
                                                                                                                                                                                                                                                                                               2800
                              1230




                                                                                                                                       S                                                   Foyer                                                                                                                               500
                                                                                                           920




                                                                                                                                                                                                         D1




                                                                                                                                                                                                                                                                                                                                                            1560
                                                                                                                                                                                                                       Entry
                                                                                                                                                                                                                                                                                                       3000
                                                                                                                                                                                                                                                                                  100
             70




                                                                                                          REF




                                                                                                                                                                                                           W4
                                       380




                                                                                                  PTY
                                                                    W8




                                                                                                                                 Lin




                                                                                                                                                                                                                                                                                                                                                               100
                                                                                                         Space
                                      70
         10180




                                                                                                                                                                                                                                                                                                                                         3970

                                                                                                                                                                                                                                                                                                                                                     4040
                                                                                    Kitchen
                                                              A
                  2900




                                                                            UBO
                                                                             RH




                                                                                                                                                                         CF
                                                                             HP
                                             2300




                                                              5                                                             Dining                                     Living
                                                                    W7




                                                                                                                                                                                                           W5
                                                                                                         Sink                                                                                                                 Living Area:      63.40 m²




                                                                                                                                                                                                                                                                                                                                                70
             70




                                                                                                                                                                                                                              Timber Deck Area: 28.42 m² + Ramp




                                                                                                                                                                                                                                                                                                                                                            5280
                                                                                              W6                                                            D2
                              1600




                                                                            / WM
                                                                            Drier
                                                                     RB1




                                                                                                                                                                                                         RB1
                  3000




                                                                                                                                                                                                                                                                                                                                                     3000
                                                                                                                   Timber Deck
                                                                                                                                                                                                                              L1: 140x45 MGP12
                  70




                                                                                                                            CF
                                                                                                                                                                                                                              RB1: 200x65 Hyne LGL GLT or 200x58 Smart LVL 15 Cont/spans
                              1330




                                                                                                                                                                                                                              RB2: 200x50 Uns. Hwd F14
                                                                                                                                                                                                                              RB3: 225x50 Uns. Hwd F14




                                                                                                                                                                                                                                                                                                                                                               100
   450




                                                                                                                            RB1


                                                                                                                                       B
                                                                                                                                       6


                                                                                           3300                                                             5030
                                                                                                                  70
                                                                                                                            8400
                                                                           70                                                                                                                       70                 2480
                                                                                     2713                                   2713                                          2713
                                                                           100                          100                                            100                                         100                                                  100
                                                                                                                            8540                                                                                        2580


                                                                                                                       Floor Plan
                                                                                                    1                      1 : 100


Client: Ken & Sorelle Christensen                                                     Address: 69 Maple St Cooroy                                                                                   Noosa Shire Council                                                                                                                                                                  Mobile: 0407 693 018        Date     9/04/2020 8:46:12 AM
                                                                                                                                                                                                                                                                                          ACCOLADE Building Designs                                                                                                  Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                                               Site Area : 1018 m²                                      Wind Classification N3                                                                                                                                                              Proprietor: Steven Horn                                            Email: [email protected]
                                                                                                                                                                                                                                                                                                                                                                                                                                         Project Number                 0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                                                                                                                                                                             QBSA Lic. 54806                                                   Issue Date:       09 - APRIL - 20                      Scale    1 : 100 Sheet No. 3    of 10

Page 4

           Pitching Level                                                                                                                                                                                Roof Sheet & Gutters to match existing Residence

          129440
                                                                            W5         W4
                                                                                                D1
                                                                                                                                                                                                                                                                          W1
                                                                                                                                                                                                               W3                           W2
           Ground Floor                                                                                                                                                                     Cladding to Match Existing Residence as close as possible (Linear Board )
          127000
 Builder to Determine exact Level on site
 to Comply with BCA for Min Ground Clearances



                                                                 Northeast Elevation
                                                         1         1 : 100                                                                                                                  Northwest Elevation
                                                                                                                                                                                     2        1 : 100


                                                                                  Door Schedule                                                                                                            Window Schedule

                                                 Mark Height Width      Comments       Location            Lintel            Jamb Studs                                 Mark Height Width       Comments                 Location                Lintel             Jamb Studs
                                                    D1   2040     920    Entry Door     ENT/Foyer      90x35 Smart LVL 14        2                                      W1    600    1500       Alum Slider     Bed 2                 90x35 Smart LVL 14                 2
                                                    D2   2100    3600   Alum Stacker      Living     2/200x35 Smart LVL 14       3                                      W2    900    1500       Alum Slider   Bathroom                90x35 Smart LVL 14                 2
                                                                                                                                                                        W3    900    2400       Alum Slider     Bed 1                 170x35 Smart LVL 14                2
                                                                                                                                                                        W4    1800    450    Alum Double Hung   Living                90x35 Smart LVL 14                 2
                                                                                                                                                                        W5    1800    450    Alum Double Hung   Living                90x35 Smart LVL 14                 2
                                                                                                                                                                        W6    1200   1800       Alum Slider    Kitchen                130x35 Smart LVL 14                2
                                                                                                                                                                        W7    900     600    Alum Double Hung Kitchen                 90x35 Smart LVL 14                 2
                                                                                                                                                                        W8    900     600    Alum Double Hung Kitchen                 90x35 Smart LVL 14                 2
                                                                                                                                                                        W9    1200   1800       Alum Slider     Bed 2                 130x35 Smart LVL 14                2




                                       W6
                                                                  D2




                                                                                                                                                                                               W9

                                                                                                                                                                                                                    W8                 W7




                                                         Southeast Elevation
                                                3        1 : 100
                                                                                                                                                           Southwest Elevation
                                                                                                                                                     4       1 : 100
Client: Ken & Sorelle Christensen                               Address: 69 Maple St Cooroy                         Noosa Shire Council                                                 Mobile: 0407 693 018        Date     9/04/2020 8:46:13 AM
                                                                                                                                          ACCOLADE Building Designs                                                 Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                             Site Area : 1018 m²              Wind Classification N3                                       Proprietor: Steven Horn            Email: [email protected]
                                                                                                                                                                                                                                                       Project Number                   0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                            QBSA Lic. 54806                   Issue Date:           09 - APRIL - 20                                 Scale      1 : 100 Sheet No. 4    of 10

Page 5

                                                                                                                                                                                               22.
             Colorbond Custom Orb Roof Sheeting                                                                                                                                                   5°
             Fixed to Manufacturers Details for N3 Wind rating

             Approved type roof battens @ 900 Ctrs
             Fixed to manufacturers details for N3

             Approved type trusses to Manufactures details @ 900 ctrs.
             1/30 mm gal looped strap 4/30 mm nails per leg
                                                                                                                                       Insulation to Dwelling to Energy Efficiency Consultant's details

             Approved type soffit lining FC Sheet
                                                                                                                                                    Plasterboard Linings to Ceilings & walls
             Top Plates 35x70 + 45x70 MGP12
             Studs 70x35 MGP12 @ 450 ctrs.




                                                                                                    2440
             Tie-down rods 12 mm Ø @ 1200 Ctrs                                                                                                                                                            920
                                                                                                                                                                                 920
             Bottom plates 70x35 MGP12


             DFJ: Double Joists under load bearing walls                                                                                                                                                                                            Balustrade to Comply to Owners selection


             FJ1: Floor joists @ 450 Ctrs.
             1/Framing anchor 4/30 mm nails per leg
                                                                                                                                                                                                                                                                                                           C2: 75 mm clearance to base of posts
             FB1: Floor bearers 2/M12 bolts to SHS
             C1: Galv SHS posts & Bitumen paint to Engineers details
                                                                                                                                                                                                                                                                                                           Pryda PSQ600100/12
                                                                                                                                                                                                                                                                                                           Post support bracket 2/M12 bolts to posts
                                                                                                                                                                                                                                                                                                           N12 rod Cranked through support
             Mass concrete footings to Engineers details




                               Section A
                 A               1 : 50



     Notes for Construction & Maintenance of Timber Decks:                                                                                                                               Recommend hot dip galvanized or stainless steel connectors & fixings be used at all times. Especially where inspections are not possible deck is to
                                                                                                                                                                                         close to ground or decking to be screwed in place to allow for easy removal to inspect sub-floor for any issues
     Builder to adhere manufactures specifications or industry standards at all times & B.C.A. 3.10.6                                                                                    Timber Queensland recommend that all timber has a moisture content of 15%
     Owners to follow manufactures details for maintenance & cleaning of deck                                                                                                            Decking boards to be fixed with 2/nails or screws & staggered or offset along the joists. Holes at ends of boards to be drilled holes to be 80% of nail
     All timber posts to be naturally durable Class 1 or 2 above ground or softwoods H3 treated if supported on bracket if in ground to be H5 Treated soft                               diameter & 12mm from ends of boards. Nails & screws to finish flush with top of boards (Not Punched). Nails or screws to be hot dipped galvanized
     or hardwood.                                                                                                                                                                        or stainless steel. Stainless Steel to be used within 900 mm of pools
     Recommend brackets or supports be used & Bitumen paint be applied to the top 200 mm of bracket in the concrete.                                                                     All Framing Anchors, Fixing Plates, Nailing Plates, Joist hangers to be Galvanised Minimum or Stainless Steel where Construction within 2.0 km
     Posts to have a Minimum 75 mm clearance from the base of the post to footing or slab & post to be 10 mm above cross member of bracket. End                                          radius of open coastal areas
     grain of post to be sealed prior to erecting.                                                                                                                                       Ends of boards to be slightly undercut at joints. Gaps between decking boards to be min 3 mm to 5 mm
     Top of concrete pad footing to be mounded to fall away from support to prevent water from ponding                                                                                   (Check with supplier Gaps range with different Types of timbers)
     Bearers, Hardwood to be H3 treated if less than 400 mm above ground H4 for touching ground H5 for in ground.                                                                        Decking boards to be fully sealed (Oiled, Stained, Painted etc.) prior to fixing.
     Joists as bearers depending on ground clearance. Joists to have Malthoid strip or bituminous paper fixed to top of joists. Softwood & Engineered                                    Recommend a light coloured sealer, with UV protection and a fungicide to be used
     manufactured timbers bearers & joists to be H3 min treated at all times. Approved connectors be used for treated timbers & location.
                                                                                                                                                                                         Maintenance & inspection of deck by Owner is to be carried out regularly
                                                                                                                                                                                         Sweep or blow, leaf or other debris off deck. Hosing or use of water to be avoided. Keep the gaps between decking boards clear of dirt & debris.
                                                                                                                                                                                         Reseal decking boards when required by manufactures recommendations
                                                                                                                                                                                         Inspect all connections for corrosion or movement regularly (Twice Yearly)
                                                                                                                                                                                         Pot plants to be on stands with a drip tray underneath & moved around regularly to prevent uneven weathering of the deck

                                                                                                                                                                                         Accolade Building Designs recommends that Builder & Home Owners read Domestic Deck Design Guide
                                                                                                                                                                                         Available on line www.timber.net.au




Client: Ken & Sorelle Christensen                                      Address: 69 Maple St Cooroy                     Noosa Shire Council                                                                                                                   Mobile: 0407 693 018        Date     9/04/2020 8:46:13 AM
                                                                                                                                                                                 ACCOLADE Building Designs                                                                               Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                           Site Area : 1018 m²                  Wind Classification N3                                                                                      Proprietor: Steven Horn                                Email: [email protected]
                                                                                                                                                                                                                                                                                                                     Project Number                     0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                                                             QBSA Lic. 54806                                       Issue Date:              09 - APRIL - 20                       Scale      1 : 50    Sheet No. 5    of 10

Page 6

     Colorbond Custom Orb Roof Sheeting
     Fixed to Manufacturers Details for N3 Wind rating
                                                                                                                                                                                                                                                                                                                     Colorbond Custom Orb Roof Sheeting
     Approved type roof battens @ 900 Ctrs                                                                                                                                                                                                                                                                           Fixed to Manufacturers Details for N3 Wind rating
     Fixed to manufacturers details for N3
                                                                                                                         RB3: Roof Beam 2/M12 bolts to posts                                                                                                                                                         Roof battens 75x38 Hwd F17 @ 900 Ctrs
                                                                                                                                                                                                                              5.0°                                                                                   Fixed 1/No. 14 batten screw to each rafter
     Approved type trusses to Manufactures details @ 900 ctrs.
     1/30 mm gal looped strap 4/30 mm nails per leg
                                                                                                                                                                                                                                                                                                                     Rafters 100x50 Uns Hwd F17 @ 900 Ctrs
     RB1: Roof beam Cont/span                                                                                                                                                                                                                                                                                        1/Framing anchor 4/30 mm nails per leg
     2/M12 bolts to posts
                                                                                                                         RB2: Roof Beams 2/M12 bolts to posts


     Approved type Ceiling lining




                                                                                                                                                                                                                                     Min. 2100
                                                                                                                         C2: 75 mm clearance to base of posts




                                                                                     2440
                                                                                                                                                                                                                                                                                                                     XB: Rod Bracing Set. 16 mm Rods
                                                                                                                         Pryda PSQ600100/12
                                                                                                                         Post support bracket 2/M12 bolts to posts
     Approved type Balustrade                                                                                            N12 rod Cranked through support




                                                                              1000
     to Owners selection
                                                                                                                                                                                                                                                                       Wheel Stop

     DJ1: Floor joists @ 450 Ctrs.                                                                                       Concrete pad footings to Engineers details                                 Concrete Slab 100 mm thick
     1/Framing anchor 4/30 mm nails per leg                                                                                                                                                         SL72 Slab fabric 50 mm cover
                                                                                                                                                                                                    NON Slip finish
     DB1: Floor bearers 2/M12 bolts to SHS
     C2: 75 mm clearance to base of posts


     Pryda PSQ600100/12
     Post support bracket 2/M12 bolts to posts
     N12 rod Cranked through support

                                                                                                  Section B                                                                                                                                      Section C
     Concrete pad footings to Engineers details
                                                                                            B       1 : 50
                                                                                                                                                                                                                            C                    1 : 50
                                                                                                                                                                                                                         UPLIFT CAPACITY OF BEAM/LINTEL TIE-DOWN CONNECTIONS


                                                                                                                                                                                                              Max 100 mm
                                                                                                                                                                                                                                                                                                    Uplift Capacity
                                                                                                                                                                      Bolt or Strap
                                         70                                                                                                                                                                                                                                          Unseasoned Timber Seasoned Timber
                                                                                                                Min 50
                                                                                                                                                                                                                                                                                     4/nails each end of strap M10 bolt to floor




                                                                                                                                                                                              250
                                                                                                                                                                                                                                                       Solid Nogging
                                                                                                                                                                                                                                                                                       17      12      8.4      12       9.8       7.4
                 Bearer                                    Min bolt Spacing                     6 bolt Ø                               6 bolt Ø                                                                                    Lintel
                                                                                                                                                                                                                                                                                     6/nails each end of strap M12 bolt to floor
                                                                 4 bolt Ø




                                                                                                                                                                                              250
                 12 mm Bolts                                                                      Bolts                                5 bolt Ø
                                                                 6 bolt Ø                                                                                                                                                                                                              17      17       12      17       14        10
                                                                                                                                       4 bolt Ø                                                                          30x0.8 G.I strap
                                                                                                                                                                      Studs as Nominated                                 No. of nails as per table
                                                                 4 bolt Ø                         Hwd Posts
                 Hwd Posts                                                                                                                                                                                                                                                          The top plate shall be fixed or tied to the lintel
                                                                                                                                                                                                                                                                                    within 100 mm of each rafter/truss, or the
                                                                                                                                                                                                                                                                                    rafter/truss fixed directly to the lintel with a fixing
                                                                                                                                                                                                                                                                                    of equivalent tie-down strength to that required




                                                                                                                                                                                                                      250
                                                                                                                                                                      Bolt to slab or floor frame                                    Opening                                        for the rafter/truss

                               Bearer - Post                                                               Beam - Post 1:10
                               1:10
                                                                                                                                                                                                    Max 100 mm
                                                                                                                                                                                                                                                    Tie-Down Requirement From AS 1684.2
                                                   Bearer/Beam Post Detail                                                                                                                                                                                     Table 9.20 (b)
                                                                                                                                                                                                                                                                                                                       Tie-down Detail
                                     1              1 : 10                                                                                                                                                                                                                                                2            1 : 30
Client: Ken & Sorelle Christensen                                     Address: 69 Maple St Cooroy                               Noosa Shire Council                                                                                                                                 Mobile: 0407 693 018                                    Date        9/04/2020 8:46:14 AM
                                                                                                                                                                                         ACCOLADE Building Designs                                                                                                                         Drawn by: S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                               Site Area : 1018 m²                       Wind Classification N3                                                                                     Proprietor: Steven Horn                                         Email: [email protected] Project Number
                                                                                                                                                                                                                                                                                                                                                                              0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                                                                       QBCC Lic. 54806                                              Issue Date             09 - APRIL - 20                                     Sheet No. 6            of   10

Page 7

                                                                               9970
                                          2980                                                   6990
                                    75                      75                    75                              75                            75
                                          2905                      2230                         2230                          2230




                                                                                                                                                                                                   10 0
                                                                                                                              75                                                       C2
                                                                                                                                  1355




                                                                                                                                                                                                       25 5
                                                                                                                                                       C2                                                                                                                                                                                                                                     Teco Bracing over rafters




                                                                                                                                                                                                         0
                                                                                                                                                                                                                                                                                                                                                                                              tensioned & looped at ends




                                                                                                                                                                                                               54 0
                                                                                                                                                                                                                                                                                                                                                                                              2/30x2.8 nails per rafter




                                                                                                                                                                                                                   0
                                                                                                                                                                                                               10 0
                                                                                                                                                     116                                          C2
                                                                                                                                                                                                                                                                                                                                                        Wind Bracing determined from AS1684.2 for N3 sites
                                                                                                                                                                                                                                                                                                                                                                     Direction B




                                                                                                                                                                                                                   25 5
                                                                                                                                                                         C2




                                                                                                                                                                                                                    0
                                                                                                                                           C2                C2                                        XB                                                                                                                                                            Required 27.3 kN Supplied 38.4 kN                                                                                XB




                                                                                                                                                                                                                                                100
                                                                                                                                                                                                                          10 0


                                                                                                                                                                                                                                 1010
                                                                                                                                                                                                                                                                                                                                                            0.9 (PB)                                                             0.9 (PB)
                                                              C1                  C1                                   C1                            C1                                                       C2                                                                                                                                                              W2                         W3




                                                                                                                                                                                                                                        2260
                                                                                                                                                                                                                                          75
                 75




                                                                                                                                                                                                                                                                                                                                             0.9 (PB)
                                                                                                 FB1




                                                                                                                                                                                                                                                                                                                                                                                                                                                1.8 (PB)
          1270




                                                                                                                                                                                                                                 1195
                                                      DFJ
                       1195




                                                                                                                                                             DJ2
                                     C1                       C1                  C1                                   C1                            C1                 DB2                  XB                                                                                                                                    W1                                                                                                                                          XB




                                                                                                                                            DFJ




                                                                                                                                                                                                                                                100
                                                                                                                                                                                                                                        75
                 75




                                                        FB1                                                       FB1                                                    C2
                                                                                                                                                                                  C2
                                                                                                                                                                                                                   100
                                                                    FJ




                                                                                                        FJ




                                                                                                                                                           Ramp




                                                                                                                                                                                                                                             1690
                                                                                                                                                                                                                                 1720
                                                                                                                                                                                                  2800




                                                                                                                                                                                                                                                                                                                                                                                                                                                 0.9 (PB)
                                                                                                                                                                                                                                                                                                                   W9
                       2965




                                                                                                                        C1          FB1 C1                        DB2
                                                                                                                                                                                       100          3000                                                                                                                                                                                                                                        DN




                                                                                                                                                                                                                                        75

                                                                                                                                                                                                                                                100
                                                                                                                                                                         C2
                                                                                                                                                                                                                                                                                                                                                                                                                                     1.4 (PB)




                                                                                                                                                                                                                                                                                                                                                                                                                     D1
                                                                                                                                                                                                                                                                        Required 29.8 kN Supplied 35.2 kN
                                                                                                                                                                                                                                             1560
                                                                                                                                                      DJ2
                                     C1                     C1                              C1                          C1
          5910




                              DFJ
          75




                                                                                                                                                                                                                                                                                                                                                                                                                         W4
                                                                      FB1




                                                                                                                                                                                                                                                                                                                   W8
                                                                                                                                                                                                                                                100
  10180




                                                                                                                                                           DB2
                                                                            FJ




                                                                                                                                  C2                                C2




                                                                                                                                                                                                                                                          Direction A
                                                                                                                                  DFJ*
                       2720




                                                                                                                                                                                                                                                                                                            1.4 (PB)




                                                                                                                                                                                                                                                                                                                                                                                                                          1.3 (PB)
                                                                                                                                                                                                                                                                                                                   W7




                                                                                                                                                                                                                                                                                                                                                                                                                         W5
                                     C1                     C1        FB1                   C1                                    C1
                 75




                                                                                                                                                                                                                                             5380
                                                                                                                                                                                                                                                                                                                                        W6                                             D2
                                                                                                                                                                                                                                                                                                                                                          0.9 (PB)                                            0.9 (PB)

                                             GS                           GS                           GS
                       2900
          3000




                                                                    DJ1




                                     C2   DB1               C2        DB1                   C2              DB1                   C2
                 100




                                                                                                                                                                   0
                                          2747                      2747                                2747                           1355           1050
                                    75                 75                              75                                    75               2480
                                                                                                                                                75                 100                                                                                                                                                    : 12mm Tie-down rods @ 1200 crs max & 100 from Openings & corners
                                          2713                      2713                                2713
                                    100                100                             100                                  100                                                                                                                                                                                         0.9 (PB)        Denotes bracing Ply 4mm F14 900 mm wide
                                                                    8540                                                                 1430         1050                                                                                                                                                                              to supply 6.4 kN/m as per AS 1684.2 Table 8.18 (h) Method A
                                                                                                                                                                   100



                                            FB1: Floor Bearers 240x65 Hyne LGL GLT or 240x58 Smart LVL 15
                                            DFJ: 2/Floor Joists 2/170x44 Hyne LGL GLT or 2/170x42 Smart LVL 15

                                                                                                                                                                                                                                                                                                                                                                        Bracing Layout
                                            DFJ*: 2/Floor Joists 2/200x44 Hyne LGL GLT or 2/200x42 Smart LVL 15
                                            FJ: Floor Joists 170x44 Hyne LGL GLT or 170x42 Smart LVL 15 @ 450 Ctrs
                                            DJ1: Deck Joists 200x50 Uns Hwd F14 @ 450 Ctrs
                                            DJ2: Deck Joists 125x50 Uns Hwd F14 @ 450 Ctrs
                                            DB1: Deck Bearers 225x75 Uns Hwd F17                                                                                                       Sub-Floor Layout                                                                                                                                                   2               1 : 100
                                            DB2: Deck Bearers 150x75 Uns Hwd F14
                                            C1: Galv SHS Posts 75x75x4.0 mm
                                            C2: Hwd Posts F14 100x100 mm H3 Treated
                                                                                                                                                                              1        1 : 100
                                            GS: 30 mm Galv. straps 1/50x3.15 mm hot-dipped galv. flat head deformed nail per joist
                                            XB: 16 mm Bracing Rod set




Client: Ken & Sorelle Christensen                                          Address: 69 Maple St Cooroy                                                                    Noosa Shire Council                                                                                                                                                                                Mobile: 0407 693 018        Date     9/04/2020 8:46:14 AM
                                                                                                                                                                                                                                    ACCOLADE Building Designs                                                                                                                                            Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                               Site Area : 1018 m²                                       Wind Classification N3                                                                                                                    Proprietor: Steven Horn                                                                                         Email: [email protected]
                                                                                                                                                                                                                                                                                                                                                                                                                                                            Project Number                0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                                                                                                                    QBSA Lic. 54806                                                                                                Issue Date:             09 - APRIL - 20                                               Scale   1 : 100 Sheet No. 7    of 10

Page 8

                                                      150mm                                                      Nail Centres:
                                                                                                                 150mm top & bottom plates                                      M10 Bolts - 15kN
                                                                                                                 150mm Vertical edges                                           M12 Bolts - 20kN
                                                                                                                 300mm intermediate studs

   M12 Rod through to top plate
   to be placed at each end of wall &
   between at Max 1200mm crs (UNO)
                                                                                                                                                                                 Double joists or
                                                                                                                                                                                 450mm long full depth cleat
                                                                                                                                                                                 Nailed to joists with
                                                                                                                                                                                 6/75x3.15mm nails


                                                                                                                                                BRACING WALL TO FLOOR JOISTS
               150mm                                                                                                                          (WALL PERPENDICULAR TO TRUSSES)



                                                                                                                                               2/ Framing anchors at
                                                                                                                                               Each end of blocking                      M10 Bolts - 15kN
                                                                                                                                               6/nails per face                          M12 Bolts - 20kN


                300mm



                                                                                                                                               Solid packer plate to suit                   100x50 F14 Hwd. or 120x45 MGP12
                                                                                                                                                                                            blocking piece on edge


                                                              Note: Where rod spacing's exceeds 1200mm,                                                            BRACING WALL TO FLOOR JOISTS
                                                                     Provide M10 bolts to bottom plate,
                                                                          At Max 1200 mm enters                                                                     (WALL PARALLEL TO TRUSSES)
                                                        PLYWOOD WALL BRACING SYSTEM
                                                                             METHOD A 6.4kN/M


                                                        MINIMUM PLYWOOD THICKNESS
                                                                                            STUD SPACING (mm)
                                                              STRESS GRADE
                                                                                              450         600
                                                                     F8                        7           9
                                                                     F11                       6           7
                                                                     F14                       4           6




                                                                                                                                                    150 Min - finished ground
                                                                     F27                       4           4.5
                                                                                                                                                                                                                Joists
                                                                                                                                                                                                      Bearers




                                                                                                                                                                                                                              400

                                                                                                                                                                                                                                    Min
                                               Bracing Wall Details
                                        1      1 : 30                                                                                                                                                    2000




Client: Ken & Sorelle Christensen                       Address: 69 Maple St Cooroy                              Noosa Shire Council                                                                                            Mobile: 0407 693 018        Date     9/04/2020 8:46:14 AM
                                                                                                                                             ACCOLADE Building Designs                                                                                      Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                         Site Area : 1018 m²                   Wind Classification N3                                            Proprietor: Steven Horn                                              Email: [email protected]
                                                                                                                                                                                                                                                                   Project Number                 0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                  QBSA Lic. 54806                                                     Issue Date:      09 - APRIL - 20          Scale   1 : 30   Sheet No. 8    of 10

Page 9

                    GENERAL SPECIFICATION                                                                                                                  Construction Notes
     Written Dimensions take Precedence over scale If in doubt call Accolade Building Designs                              Timber Frame: Framing to be built in accordance with AS 1684 Termite protected timbers shall be used on all framing
     Builder to verify all dimensions & levels on site prior to commencement of work                                       Approved type flashing & sarking to be attached between cladding & frame along with slab & frame to prevent moisture getting to the frames
     All boundary setbacks to be strictly adhered to as minimum setbacks apply                                             All wet areas to be made waterproof or resistant to comply to AS 3740 & BCA 3.8.1
     Verify location of all services on site & all floor levels allow for connection to these services                     Linings used shall be approved for use in wet areas & shall be fixed in strict accordance
     All building work to be carried out to Aust Standards & to the relevant building codes of Australia                   with Manufactures specifications. Recommended that all showers have a waterproofed hob
     Builder to supply footpath protection & show required signage to comply to council regulations &                      Water stops or vertical barriers in the waterproofing system be installed to prevent passage of moisture in the floor to non wet areas of building
     comply to the Workplace Health & Safety act.                                                                          Recommend Laundry floor to have a dry waste in floor & grade floor to it or to door to allow for overflow
                                                                                                                           Wet Areas include Bathrooms Ensuite Laundry & WC or Powder rooms
     Builder to supply sediment control where needed
     All work to comply to the National Construction Codes 2014                                                            Tiled areas: Tiles to laid or fixed to a clean dry substrate to comply to AS 3958
     Termite protection to AS. 3660.1 2/durable notices to be installed in prominent locations stating                     Ensure water proofing is dry & is suitable for the adhesives or grouts to be applied to
     method of protection, Date of installation, Life expectancy & frequency of inspections                                Ensure the correct tile is being used for the application (ie. Floor tiles on Floors)
     Smoke alarms to comply to AS. 3786 Hardwired in & interconnected
                                                                                                                           All walls to be checked to ensure they are fixed correctly, straight & plumb prior to fixing plasterboard or interior lining
     Concrete slab & footings to be designed by Engineers from Soils Tests & to comply with AS. 2870                       Plasterboard or interior linings to be fixed to dry frames in strict compliance with manufactures details. Setting of plasterboard to be done in strict
     All structural Timbers to comply with National Timber Framing Codes AS. 1684.2 & AS . 1720 &                          compliance with manufactures specifications, Sanded to provide a flat smooth finish
     Construction Timbers Queensland(CTIQ)
     All Steelwork to comply to AS. 4100 for steel structures                                                              Painting: Paints & application to comply to AS 2311 Min 3 coat application system to be used
     Roof trusses to be designed by manufacture & Certified, Truss manufacture to determine or confirm                     Substrate to be clean & dry correct type sealers & primers to be used for substrate
                                                                                                                           If paint is sprayed on then a back roll should be done between coats & after final coat
     all lintel sizes under standard & Girder trusses for load bearing capabilities                                        Mould resistant paint to be used in Bathrooms, Ceilings to have approved ceiling paint applied & be a matt finish
     Lighting to comply with AS.1680.1 & B.C.A. Vol 2 Part 3.8.4.2 & 3
     Electrical installations to comply to AS. 3000 & other relevant regulations                                           All external manufactured timbers to be H3 Treated & sealed painted or encased made weather proof
     Plumbing & drainage to comply to AS. 3500 Hot water system to AS. 3500 4.1                                            in strict accordance with the manufactures specifications
     Internal Wet Areas to comply to AS. 3740 as in B.C.A. Vol 2, Part 3.8.1
                                                                                                                           Concrete slabs & footings to be poured to Structural Engineers Specifications & in accord with AS 2870
     External waterproofing to comply to AS. 4654                                                                          External concrete shall be have a NON-Slip Finish or a NON-slip coating applied to the surface
     Windows & Glazing to AS.2047 -1999 Screening or security screens to comply to
     relevant regulations. Type of glass used to be determined by Energy Efficiency Consultant                             Approved type Structaflor 19 mm (Yellow Tongue) to be used fixed to Manufactures specifications
     Plasterboard to AS. 2589 Painting to AS. 2311 Tiling to AS. 3958                                                      Wet areas to use Hardies Scyon Secura internal flooring or Similar, waterproofed & Tiled in accord with relevant standards
     Insulation to roof cavity & walls to be determined by Licensed Energy Efficiency Consultant to
                                                                                                                           All external windows & doors to have appropriate flashing & seals fitted to prevent water getting into building or to the frame work
     Comply to Aust. & QLD. Standards & requirements                                                                       For all installations of windows follow manufactures instructions or Installation & Fixing Guide at www.awa.org.au
     Structural members Wind bracing & tie-down to be certified or designed by Structural Engineer
     WC to be installed with 4.5/3 L dual flush cistern or better                                                          New Dwelling; to have Min. 50 % of specified bracing installed prior to roof going on
     All taps & Shower roses to be AAA Conservation rating                                                                 Existing Dwelling; During construction temporary propping & bracing to consulting Engineers satisfaction
     All roof water to be discharged to Council approved drainage point or street
                                                                                                                           Gang nail Splice plates NOT permitted for exterior timber beams
     All waste water to be connected to existing sewerage system
     Stairs to B.C.A. Vol 2 Part 3.9.1 Balustrade Part 3.9.2
     Timber Decks to be built to B.C.A. 3.10.6
     These plans are for Certification & Building only. Items like Flooring, Tiles, Painting & other finishes
     Cabinetry Etc. to be decide by Owner & Builder prior Contract being signed Items must comply to relevant codes        Notes for Construction & Maintenance of Roofs
     The Builder must have Building Approval for the proposed works from a Building Certifier prior to work commencing
                                                                                                                           All timber trusses or rafters fixed in accord with AS 1684.2 for designated wind classification
                                                                                                                           Steel Roof battens fixed to Manufactures specifications for the spans, roofing type & Wind classification.
                                                                                                                           Timber roof battens fixed to AS1684.2 as per above
                                                                                                                           Roofing, Flashing & Gutters to be of compatible materials
                                                                                                                           Roof sheeting or tiles to be fixed to Manufactures specifications for N3 sites
                                                                                                                           Approved type sarking to be placed under roof sheet over battens fixed to Manufactures details
                                                                                                                           Screws to AS. 3566:2002 Class 3 or better. Blind rivets to be used screws & Rivets to be compatible material
                                                                                                                           Gutters to be fixed to AS/NZS 3500.3 2003. Gutter to have adequate fall to downpipes Min 1:500
                                                                                                                           Front of gutter to be lower than top of fascia or slots in the front of the gutter, or flashing behind gutter &
                                                                                                                           under the roof sheets fixed to roof battens to prevent water getting into roof cavity or soffit area
                                                                                                                           Adequate down pipes in appropriate places with rain water heads fitted Max 12 m spaces to be determined by Plumber
                                                                                                                           Recommend a good quality gutter guard be fitted to prevent leaf & other debris getting into gutter to block downpipes
                                                                                                                           Regular inspections & cleaning of gutters to be done depending on trees around the home
                                                                                                                           Regular cleaning & inspections of the roof is to be done including ensuring screws are still tight on the roof sheet
                                                                                                                           & neoprene washers are not cracking or degrading. Tiles are not cracked or loose & all grouting is in place & holding tiles firm & in place
                                                                                                                           (Recommended that a professional is called in with appropriate safety equipment to do inspections & cleaning)




Client: Ken & Sorelle Christensen       Address: 69 Maple St Cooroy            Noosa Shire Council                                                                                          Mobile: 0407 693 018                               Date      9/04/2020 8:46:15 AM
                                                                                                              ACCOLADE Building Designs                                                                                                       Drawn by: S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605         Site Area : 1018 m²       Wind Classification N3                                             Proprietor: Steven Horn                                 Email: [email protected] Project Number
                                                                                                                                                                                                                                                                              0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                         QBCC Lic. 54806                                      Issue Date            09 - APRIL - 20                              Sheet No. 9          of    10

Page 10

             1. FALLS, SLIPS, TRIPS                                                       2. FALLING OBJECTS                                                          5. MANUAL TASKS                                                             7. CONFINED SPACES
             a) WORKING AT HEIGHTS                                                        LOOSE MATERIALS OR SMALL OBJECTS                                            Components within this design with a mass in excess of 25kg                 EXCAVATION
             DURING CONSTRUCTION                                                          Construction, maintenance or demolition work on or around this              should be lifted by two or more workers or by mechanical lifting            Construction of this building and some maintenance on the
             Wherever possible, components for this building should be                    building is likely to involve persons working above ground level or         device. Where this is not practical, suppliers or fabricators should        building will require excavation and installation of items within
             prefabricated off-site or at ground level to minimise the risk of            above floor levels. Where this occurs one or more of the following          be required to limit the component mass.                                    excavations. Where practical, installation should be carried out
             workers falling. However, construction of this                               measures should be taken to avoid objects falling from the area             All material packaging, building and maintenance components                 using methods which do not require workers to enter the
             building will require workers to be working at heights where a fall in       where the work is being carried out onto persons below.                     should clearly show the total mass of packages and where                    excavation. Where this is not practical, adequate support for the
             excess of two metres is possible and injury is likely to result from such    1. Prevent or restrict access to areas below where the work is              practical all items should be stored on site in a way which                 excavated area should be provided to prevent collapse. Warning
             a fall. The builder should provide a suitable barrier wherever a                being carried out.                                                       minimises bending before lifting. Advice should be provided on              signs and barriers to prevent accidental or unauthorised access to
             person is required to work in a situation where falling more than            2. Provide toeboards to scaffolding or work platforms.                      safe lifting methods in all areas where lifting may occur.                  all excavations should be provided.
             two metres is a possibility.                                                 3. Provide protective structure below the work area.                        Construction, maintenance and demolition of this building will              ENCLOSED SPACES
             DURING OPERATION OR MAINTENANCE                                              4. Ensure that all persons below the work area have Personal                require the use of portable tools and equipment. These should be            For buildings with enclosed spaces where maintenance or other
             For houses or other low-rise buildings where scaffolding is                     Protective Equipment (PPE).                                              fully maintained in accordance with manufacturer’s                          access may be required:
             appropriate:                                                                                                                                             specifications and not used where faulty or (in the case of                 Enclosed spaces within this building may present a risk to persons
                                                                                          BUILDING COMPONENTS                                                         electrical equipment) not carrying a current electrical safety tag.
             Cleaning and maintenance of windows, walls, roof or other                    During construction, renovation or demolition of this building, parts of                                                                                entering for construction, maintenance or any other purpose. The
             components of this building will require persons to be situated                                                                                          All safety guards or devices should be regularly checked and                design documentation calls for warning signs and barriers to
                                                                                          the structure including fabricated steelwork, heavy panels and many         Personal Protective Equipment should be used in accordance
             where a fall from a height in excess of two metres is possible. Where        other components will remain standing prior to or after supporting                                                                                      unauthorised access. These should be maintained throughout the
             this type of activity is required, scaffolding, ladders or trestles should                                                                               with manufacturer’s specification.                                          life of the building. Where workers are required to enter enclosed
                                                                                          parts are in place. Contractors should ensure that temporary bracing
             be used in accordance with relevant codes of practice,                                                                                                                                                                               spaces, air testing equipment and Personal Protective Equipment
             regulations or legislation.
                                                                                          or other required support is in place at all times when collapse which      6. HAZARDOUS SUBSTANCES                                                     should be provided.
                                                                                          may injure persons in the area is a possibility.                            ASBESTOS
             For buildings where scaffold, ladders, trestles are not appropriate:                                                                                                                                                                 SMALL SPACES
             Cleaning and maintenance of windows, walls, roof or other                                                                                                For alterations to a building constructed prior to 1990:
                                                                                          Mechanical lifting of materials and components during construction,                                                                                     For buildings with small spaces where maintenance or other access
             components of this building will require persons to be situated                                                                                          If this existing building was constructed prior to:
                                                                                          maintenance or demolition presents a risk of falling objects.                                                                                           may be required:
             where a fall from a height in excess of two metres is possible. Where                                                                                    1990 - it therefore may contain asbestos
                                                                                          Contractors should ensure that appropriate lifting devices are used,                                                                                    Some small spaces within this building will require access by
             this type of activity is required, scaffolding, fall barriers or Personal                                                                                1986 - it therefore is likely to contain asbestos
                                                                                          that loads are properly secured and that access to areas below the                                                                                      construction or maintenance workers. The design documentation
             Protective Equipment (PPE) should be used in accordance with                                                                                             either in cladding material or in fire retardant insulation material. In
                                                                                          load is prevented or restricted.                                                                                                                        calls for warning signs and barriers to unauthorised access. These
             relevant codes of practice, regulations or legislation.                                                                                                  either case, the builder should check and, if necessary, take
                                                                                                                                                                                                                                                  should be maintained throughout the life of the building. Where
                                                                                                                                                                      appropriate action before demolishing, cutting, sanding, drilling or
                                                                                                                                                                                                                                                  workers are required to enter small spaces they should be
             b) SLIPPERY OR UNEVEN SURFACES                                               3. TRAFFIC MANAGEMENT                                                       otherwise disturbing the existing structure.
                                                                                                                                                                                                                                                  scheduled so that access is for short periods. Manual lifting and
                                                                                          For building on a major road, narrow road or steeply sloping road:          POWDERED MATERIALS                                                          other manual activity should be restricted in small spaces.
             FLOOR FINISHES Specified                                                     Parking of vehicles or loading/unloading of vehicles on this roadway        Many materials used in the construction of this building can cause
             If finishes have been specified by designer, these have been                 may cause a traffic hazard. During construction, maintenance or             harm if inhaled in powdered form. Persons working on or in the              8. PUBLIC ACCESS
             selected to minimise the risk of floors and paved areas becoming             demolition of this building designated parking for workers and loading      building during construction, operational maintenance or demolition         Public access to construction and demolition sites and to areas
             slippery when wet or when walked on with wet shoes/feet. Any                 areas should be provided. Trained traffic management personnel              should ensure good ventilation and wear Personal Protective                 under maintenance causes risk to workers and public. Warning
             changes to the specified finish should be made in consultation with          should be responsible for the supervision of these areas.                   Equipment including protection against inhalation while using               signs and secure barriers to unauthorised access should be
             the designer or, if this is not practical, surfaces with an equivalent or    For building where on-site loading/unloading is restricted:                 powdered material or when sanding, drilling, cutting or otherwise           provided. Where electrical installations, excavations, plant or loose
             better slip resistance should be chosen.                                     Construction of this building will require loading and unloading of         disturbing or creating powdered material.                                   materials are present they should be secured when not fully
             FLOOR FINISHES By Owner                                                      materials on the roadway. Deliveries should be well planned to avoid                                                                                    supervised.
             If designer has not been involved in the selection of surface                                                                                            TREATED TIMBER
                                                                                          congestion of loading areas and trained traffic management                  The design of this building may include provision for the inclusion of      9. OPERATIONAL USE OF BUILDING
             finishes, the owner is responsible for the selection of surface finishes     personnel should be used to supervise loading/unloading areas.              treated timber within the structure. Dust or fumes from this material       RESIDENTIAL BUILDINGS
             in the pedestrian trafficable areas of this building. Surfaces should        For all buildings:
             be selected in accordance with AS HB 197:1999 and AS/NZ                                                                                                  can be harmful. Persons working on or in the building during                This building has been designed as a residential building. If it, at a
                                                                                          Busy construction and demolition sites present a risk of collision where    construction, operational maintenance or demolition should ensure
             4586:2004.                                                                   deliveries and other traffic are moving within the site. A traffic                                                                                      later date, it is used or intended to be used as a workplace, the
                                                                                                                                                                      good ventilation and wear Personal Protective Equipment including           provisions of the Work Health and Safety Act 2011 or subsequent
             STEPS, LOOSE OBJECTS AND UNEVEN SURFACES                                     management plan supervised by trained traffic management
             Due to design restrictions for this building, steps and/or ramps are                                                                                     protection against inhalation of harmful material when sanding,             replacement Act should be applied to the new use.
                                                                                          personnel should be adopted for the work site.                              drilling, cutting or using treated timber in any way that may cause
             included in the building which may be a hazard to workers carrying
                                                                                                                                                                      harmful material to be released. Do not burn treated timber.                10.OTHER HIGH RISK ACTIVITY
             objects or otherwise occupied. Steps should be clearly marked with           4. SERVICES
             both visual and tactile warning during construction, maintenance,                                                                                        VOLATILE ORGANIC COMPOUNDS                                                  All electrical work should be carried out in accordance with Code
                                                                                          GENERAL                                                                     Many types of glue, solvents, spray packs, paints, varnishes and
             demolition and at all times when the building operates as a                                                                                                                                                                          of Practice: Managing Electrical Risks at the Workplace, AS/NZ
                                                                                          Rupture of services during excavation or other activity creates a           some cleaning materials and disinfectants have dangerous
             workplace.                                                                                                                                                                                                                           3012 and all licensing requirements.
                                                                                          variety of risks including release of hazardous material. Existing          emissions. Areas where these are used should be kept well
             Building owners and occupiers should monitor the pedestrian                                                                                                                                                                          All work using Plant should be carried out in accordance with
                                                                                          services are located on or around this site. Where known, these are         ventilated while the material is being used and for a period after
             access ways and in particular access to areas where maintenance                                                                                                                                                                      Code of Practice: Managing Risks of Plant at the Workplace.
                                                                                          identified on the plans but the exact location and extent of                installation. Personal Protective Equipment may also be required.
             is routinely carried out to ensure that surfaces have not moved or                                                                                                                                                                   All work should be carried out in accordance with Code of
                                                                                          services may vary from that indicated. Services should be located           The manufacturer’s recommendations for use must be carefully
             cracked so that they become uneven and present a trip hazard.                                                                                                                                                                        Practice: Managing Noise and Preventing Hearing Loss at Work.
                                                                                          using an appropriate service (such as Dial Before You Dig),                 considered at all times.
             Spills, loose material, stray objects or any other matter that may                                                                                                                                                                   Due to the history of serious incidents it is recommended that
                                                                                          appropriate excavation practice should be used and, where
             cause a slip or trip hazard should be cleaned or removed from                                                                                            SYNTHETIC MINERAL FIBRE                                                     particular care be exercised when undertaking work involving steel
                                                                                          necessary, specialist contractors should be used.
             access ways.                                                                                                                                             Fibreglass, rockwool, ceramic and other material used for thermal or        construction and concrete placement. All the above applies.
                                                                                          Locations with underground power:
             Contractors should be required to maintain a tidy work site during                                                                                       sound insulation may contain synthetic mineral fibre which may be
                                                                                          Underground power lines MAY be located in or around this site. All
             construction, maintenance or demolition to reduce the risk of trips                                                                                      harmful if inhaled or if it comes in contact with the skin, eyes or other
                                                                                          underground power lines must be disconnected or carefully
             and falls in the workplace. Materials for construction or                                                                                                sensitive parts or the body. Personal Protective Equipment including
                                                                                          located and adequate warning signs used prior to any
             maintenance should be stored in designated areas away from                                                                                               protection against inhalation of harmful material should be used when
                                                                                          construction, maintenance or demolition commencing.
             access ways and work areas.                                                                                                                              installing, removing or working near bulk insulation material.
                                                                                          Locations with overhead power lines:
                                                                                          Overhead power lines MAY be near or on this site. These pose a risk         TIMBER FLOORS
                                                                                          of electrocution if struck or approached by lifting devices or other        This building may contain timber floors which have an applied finish.
                                                                                          plant and persons working above ground level. Where there is a              Areas where finishes are applied should be kept well ventilated during
                                                                                          danger of this occurring, power lines should be, where practical,           sanding and application and for a period after installation. Personal
                                                                                          disconnected or relocated. Where this is not practical adequate             Protective Equipment may also be required. The manufacturer’s
                                                                                          warning in the form of bright coloured tape or signage should be            recommendations for use must be carefully considered at all times.
                                                                                          used or a protective barrier provided.




                                                                                   THESE NOTES MUST BE READ AND UNDERSTOOD BY ALL INVOLVED IN THE PROJECT.
                                                                                   THIS INCLUDES (but is not excluded to): OWNER, BUILDER, SUB-CONTRACTORS, CONSULTANTS, RENOVATORS, OPERATORS, MAINTAINERS, DEMOLISHERS.
                                                                                   THE ONSITE BUILDERS WORKPLACE HEALTH & SAFETY MANAGEMENT PLAN SPECIFIC TO THIS SITE OVERRIDES THESE NOTES



Client: Ken & Sorelle Christensen                        Address: 69 Maple St Cooroy                              Noosa Shire Council                                                                                                              Mobile: 0407 693 018                                Date      9/04/2020 8:46:15 AM
                                                                                                                                                                     ACCOLADE Building Designs                                                                                                        Drawn by: S.Horn Drawn for A3 Sheet
RPD: Lot 4 on C5605                  Site Area : 1018 m²                        Wind Classification N3                                                                         Proprietor: Steven Horn                                    Email: [email protected] Project Number
                                                                                                                                                                                                                                                                                                                                   0619CKS
Proposed Secondary Residence on SHS Posts Timber Framed, Sheet Roof                                                                                                               QBCC Lic. 54806                                         Issue Date          09 - APRIL - 20                               Sheet No. 10      of   10

Used in these records

About this file

File size
385 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SEC Constructions_P3_S1_Secondary Residence Plan.pdf · 385 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.