PEREGIAN BEACH VILLAS
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
Sheet Index
Layout ID Layout Name Published
Sheet Index
A.01.1 COVER PAGE
A.01.2 GROUND FLOOR
A.01.3 FIRST FLOOR
A.01.4 ELEVATIONS
A.01.5 ELEVATIONS
NOTES
INSERT SKETCH RENDER
FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS
AREAS
GENERAL NOTES GROSS FLOOR AREA
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 8: 56m2
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 9: 56 m2
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SCHEDULES OF FINISHES.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Collins Developments
DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398
facsimilie
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected]
FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
4,905 250 4,905 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
90 1,725 90 3,000 250 3,000 90 1,725 90 ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
600
600
THE ENTRY OF MOISTURE INTO THE BUILDING.
1,360 140
1,360 140
2,100
2,100
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
Patio Patio 3.8.1 OF THE B.C.A AND AS 3740
1.4 x 4.9 1.4 x 4.9
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
90 STANDARDS.
90
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
Ens Bed Bed Ens AS3788 & PART 3.72 OF THE BCA
3,300
3,300
2.5 x 1.7 3.3 x 3.0 3.3 x 3.0 2.5 x 1.7
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
WC WC
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
REQUIREMENTS
Bi-fold doors by 16W W16
cabinet maker
90
90
15 15 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
14
T T 14 AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
ROBE ROBE
550
550
Laundry underneath 13 13 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
staicase 12 12 FOR MEMBER SIZES
90
90
LEGEND
11 11
10 UNIT 8 UNIT 9 10
A/C AIR CONDITIONING AS SPEC. - INSTALLED
10,210
10,210
9 9
8 8 BY CONTRACTOR
Bistro style blinds to 7 7 AP 450 X450 REMOVABLE ACCESS
external staircase 6 6 PANEL - LOCATION TO BE CONFIRMED ON SITE
5 5 BL CONC. BLOCK WALL TO STRUCTURAL ENG.
Staircase open to 4 4 DETAIL - RENDER AND PAINT AS SPEC.
CF COLORBOND FLASHING TO DETAIL
external units 3 3
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
2 2
Single Garage Single Garage CONC CONCRETE SLAB TO ENG. DETAIL
1 1
6.0 x 3.0 6.0 x 3.0
6,000
6,000
CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
EGL EXISTING GROUNDLINE
F REFRIGERATOR
FW FLOOR WASTE
GD S.S GRATED DRAIN AS SPEC.
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
HWU HOT WATER
90
90
780
780
MR MECHANICAL RISER
MW MICROWAVE
NGL NATURAL GROUND LINE
780
780
OV OVEN
P PANTRY
PGL PROPOSED GROUNDLINE
90 1,725 90 3,000 250 3,000 90 1,725 90 PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
4,905 250 4,905 S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site plan revisions + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22.01.14 Client request amendments CT
PH: 0410 650 745
GROUND FLOOR
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.2 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 3
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
410 4,905 250 4,905 410
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
90 2,835 90 2,300 250 2,300 90 2,835 90
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
90
90
THE ENTRY OF MOISTURE INTO THE BUILDING.
90
90
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
2,590
2,590
Outdoor living Outdoor living ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
4.8 x 2.5 4.8 x 2.5 AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
90
90
AS3788 & PART 3.72 OF THE BCA
Bay Window
Bay Window
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Living Living
4.8 x 2.4 4.8 x 2.4
7,580
7,580
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
16 16 REQUIREMENTS
15 15
4,480
4,480
14 14 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
13 13
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
12 12
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
11,800
11,800
11 11
FOR MEMBER SIZES
10
9 Kitchen Kitchen
10
9
LEGEND
8 2.8 x 3.0 2.8 x 3.0 8 A/C AIR CONDITIONING AS SPEC. - INSTALLED
7 7 BY CONTRACTOR
6 6
AP 450 X450 REMOVABLE ACCESS
PANEL - LOCATION TO BE CONFIRMED ON SITE
90
90
5 5
BL CONC. BLOCK WALL TO STRUCTURAL ENG.
4 4
DETAIL - RENDER AND PAINT AS SPEC.
90
90
3 3
CF COLORBOND FLASHING TO DETAIL
2 2
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
1 1
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
Study Study REFER TO DETAILS FOR TYPICAL FIXING
3,000
3,000
3.7 x 3 3.7 x 3 DRY CLOTHES DRYER
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
WC
GUTTER BRACKETS @ MAX 900 CRS
WC
EGL EXISTING GROUNDLINE
F REFRIGERATOR
FW FLOOR WASTE
90
90
GD S.S GRATED DRAIN AS SPEC.
Balcony Balcony HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
HWU HOT WATER
1,090
1,090
MR MECHANICAL RISER
MW MICROWAVE
NGL NATURAL GROUND LINE
250 OV OVEN
500 90 3,635 90 1,000 1,000 90 3,635 90 500 P PANTRY
PGL PROPOSED GROUNDLINE
PTF POLISHED TIMBER FLOOR AS SPEC.
4,815 250 4,815 RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site plan revisions + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22.01.14 Client request amendments CT
PH: 0410 650 745
FIRST FLOOR
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.3 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 4
PEREGIAN BEACH VILLAS
ELEVATION LEGEND
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
D-0 DOOR NUMBER
WD-0 WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
DP1 90Ø DOWNPIPE
FL
Roof sheets @ 120 pitch fixed EG1 EAVES GUTTER
FC FIBRE CEMENT WITH 10mm EXPRESSED
in accordance with
Roof sheets @ 140 pitch fixed in manufactures specification
JOINTS
MRS FCC COMPRESSED FIBRE CEMENT
accordance with manufactures MRS
FL FLASHING
specification
LVF FIXED ALUMINIUM LOUVRE
EG1 MRS METAL ROOF SHEETING
Ceiling Level Ceiling Level
FL ZINC ZINC CLADDING WITH STANDING SEAM
EG1 NGL NATURAL GROUND LINE
Bay window, with specified cladding fixed FL PLY PLYWOOD WITH 10mm EXPRESSED
in accordance with manufactures JOINTS
specification Aluminium framed windows SPR SPREADER
2,740
2,740
fixed to manufactures SPT SPITTER
specifications
Floor Level
Timber ballustrade, in accordance with the Timber screen Floor Level
Ceiling Level BCA and relevant Aus Standards Ceiling Level
Steel post in accordance with engineers Aluminium screen, in
specifications
2,740
2,740
accordance with manufacteres
specifications
Specified cladding fixed in accordance with
manufactures specification
Slab Level NGL NGL Slab Level
1 Left Elevation 1:100
Roof sheets @ 140 pitch fixed
MRS MRS
in accordance with
manufactures specification
Ceiling Level Ceiling Level
EG1 EG1
Bay window with specified horizontal
cladding fixed in accordance with
Timber ballustrade, in manufactures specification
accordance with the BCA and
2,740
2,740
relevant Aus Standards Aluminium framed bifold windows beyond
fixed to manufactures specifications
Fire rated wall in accordance
with manufacturers
Floor Level specifications Floor Level
Ceiling Level
Ceiling Level Specified vertical cladding fixed in
accordance with manufactures
specification
2,740
2,740
Aluminium framed doors fixed Steel post in accordance with engineers
to manufactures specifications specifications
Slab Level NGL NGL Slab Level
2 Rear Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site plan revisions + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.4 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 5
PEREGIAN BEACH VILLAS
ELEVATION LEGEND
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
D-0 DOOR NUMBER
WD-0 WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
FL DP1 90Ø DOWNPIPE
Roof sheets @ 70 pitch fixed EG1 EAVES GUTTER
FC FIBRE CEMENT WITH 10mm EXPRESSED
in accordance with
JOINTS
manufactures specification MRS MRS Roof sheets @ 140 pitch fixed in FCC COMPRESSED FIBRE CEMENT
accordance with manufactures FL FLASHING
specification LVF FIXED ALUMINIUM LOUVRE
EG1 MRS METAL ROOF SHEETING
Ceiling Level Ceiling Level ZINC ZINC CLADDING WITH STANDING SEAM
FL NGL NATURAL GROUND LINE
Bay window, with specified cladding fixed PLY PLYWOOD WITH 10mm EXPRESSED
Aluminium framed windows in accordance with manufactures JOINTS
fixed to manufactures specification SPR SPREADER
2,740
2,740
SPT SPITTER
specifications
Timber screen
Timber ballustrade, in
accordance with the BCA and Floor Level
Floor Level relevant Aus Standards Ceiling Level
Ceiling Level
Timber post in accordance with engineers
Aluminium screen, in specifications
2,740
2,740
accordance with manufacteres
specifications Specified cladding fixed in accordance with
manufactures specification
Slab Level NGL NGL Slab Level
3 Right 1 Elevation 1:100
Fire rated wall in accordance
with manufacturers Specified vertical cladding
specifications
Aluminium framed windows
fixed to manufactures
Roof sheets @ 70 pitch fixed specifications
in accordance with MRS
manufactures specification
Ceiling Level Ceiling Level
EG1
Exposed rafters to roof system
Specified vertical cladding
2,740
2,740
Timber screen Glass ballustrade, in
accordance with BCA and Aus
Floor Level standards Floor Level
Ceiling Level Ceiling Level
Specified cladding
Aluminium screen, in
2,740
2,740
accordance with manufacteres
specifications
21 - 24 roller door
Slab Level NGL NGL Slab Level
4 Front Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site plan revisions + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.5 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES