Original source · versioned page text
Attachment 1E - UNITS 8-9
Attached to the e-mail Development Application MCU14/0008 - 226 David Low Way Peregian Beach Units 8-9 (Email 7).
PEREGIAN BEACH VILLAS
ELEVATION LEGEND
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
D-0 DOOR NUMBER
WD-0 WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
DP1 90Ø DOWNPIPE
FL
Roof sheets @ 120 pitch fixed EG1 EAVES GUTTER
FC FIBRE CEMENT WITH 10mm EXPRESSED
in accordance with
Roof sheets @ 140 pitch fixed in manufactures specification
JOINTS
MRS FCC COMPRESSED FIBRE CEMENT
accordance with manufactures MRS
FL FLASHING
specification
LVF FIXED ALUMINIUM LOUVRE
EG1 MRS METAL ROOF SHEETING
Ceiling Level Ceiling Level
FL ZINC ZINC CLADDING WITH STANDING SEAM
EG1 NGL NATURAL GROUND LINE
Bay window, with specified cladding fixed FL PLY PLYWOOD WITH 10mm EXPRESSED
in accordance with manufactures JOINTS
specification Aluminium framed windows SPR SPREADER
2,740
2,740
fixed to manufactures SPT SPITTER
specifications
Floor Level
Timber ballustrade, in accordance with the Timber screen Floor Level
Ceiling Level BCA and relevant Aus Standards Ceiling Level
Steel post in accordance with engineers Aluminium screen, in
specifications
2,740
2,740
accordance with manufacteres
specifications
Specified cladding fixed in accordance with
manufactures specification
Slab Level NGL NGL Slab Level
1 Left Elevation 1:100
Roof sheets @ 140 pitch fixed
MRS MRS
in accordance with
manufactures specification
Ceiling Level Ceiling Level
EG1 EG1
Bay window with specified horizontal
cladding fixed in accordance with
Timber ballustrade, in manufactures specification
accordance with the BCA and
2,740
2,740
relevant Aus Standards Aluminium framed bifold windows beyond
fixed to manufactures specifications
Fire rated wall in accordance
with manufacturers
Floor Level specifications Floor Level
Ceiling Level
Ceiling Level Specified vertical cladding fixed in
accordance with manufactures
specification
2,740
2,740
Aluminium framed doors fixed Steel post in accordance with engineers
to manufactures specifications specifications
Slab Level NGL NGL Slab Level
2 Rear Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site plan revisions + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.4 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.