ELECTRICAL QUANTITIES NBN CONNECTION LEGEND - INTERNAL
BC - BROOM CUPBOARD
DESCRIPTION No. INSTALL 1x DGPO. C'BD - CUPBOARD
DP - DOWNPIPE
FAN - CEILING FAN ONLY 12 SUPPLY & TERMINATE 1x DATA POINT CAT 6 CABLE. DW - DISHWASHER PROV.
FAN - EXHAUST 8 SUPPLY & TERMINATE 1x PHONE POINT CAT 6 CABLE. FW - FLOOR WASTE
SUPPLY & INSTALL 1x LEAD IN FROM PIT TO SIDE OF HP - HOT PLATE
LIGHT FITTING - DOUBLE SPOT LIGHT 8 HWS - HOT WATER SYSTEM
HOUSE P20 PIPE WITH DRAW WIRE. L - LINEN
LIGHT FITTING - RECESSED LED 71
SUPPLY & TERMINATE THE 2 CAT 6 POINTS IN GARAGE MH - MANHOLE
LIGHT FITTING - SINGLE 35W LED 4 TO 2-GANG SWITCH FOR INTERNAL CONNECTIONS. MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
LIGHT FITTING - WALL MOUNT UP/DOWN 8 PTY - PANTRY
POINT - DOUBLE GPO 56 R - ROBE
REF - REFRIDGERATOR SPACE
POINT - PHONE 4 RH - RANGEHOOD
POINT - SINGLE GPO 20 SH - SHELF
TR - TOWEL RAIL
POINT - TELEVISION POINT 4 TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
SMOKE ALARM 12 WO - WALL OVEN
LEGEND - EXTERNAL
BV - BRICK VENEER
CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
SPOT LIGHT WALL MOUNT WALL MOUNT SPOT LIGHT RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
LED LED
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
A/C POSTION A/C POSTION
METERBOX METERBOX SA - SCYON AXON
SL - SCYON LINEA
SM - SCYON MATRIX PANELING
LED LED 2 2 LED LED SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT
LED LED
IN CEILING IN CEILING
LED LED LED LED
35W LED 35W LED
WALL MOUNT
1000 1000
WALL MOUNT SGPO IN CEILING FOR
SGPO IN CEILING FOR
ELECTRICAL LEGEND ANTENNA BOOSTER
ANTENNA BOOSTER
LED LED M/H 555X555 M/H 555X555 LED LED
ISSUE
CEILING FAN SGPO (1900) REF LED LED SGPO (1900) REF # DATE DETAILS BY
- 23-07-21 CONCEPT ISS. DC
2
2
1000
1000 - 06-08-21 CONCEPT ISS. A JS
1000 1000
CEILING FAN / LIGHT COMBINATION SGPO (1750) RH - 10-09-21 NHP ISSUE AN
LED LED 27-09-21 WD ISSUE JB
LED LED LED LED
EXHAUST FAN 1000
1000
HEAT FAN & LIGHT LED LED
LIGHT POINT - CFL (32w / 22w)
A/C UNIT
A/C UNIT
B LIGHT POINT - BATTEN
LIGHT POINT - LED LED LED LED LED
po box 6384 p (07) 5319 1500
A/C POSTION
A/C POSTION
A/C POSTION
A/C POSTION
EXTERNAL FLOOD LIGHT maroochydore f (07) 5450 6437
qld 4558 QBCC 1083000
WALL LIGHT
LED LED WRITTEN DIMENSIONS TO TAKE
35W LED PRECEDENCE OVER SCALE
1000 LED LED 1000
GPO - DOUBLE LED LED ELECTRICAL UNIT
GPO - SINGLE 1-2
SPOT LIGHT A/C UNIT HWS HWS A/C UNIT SPOT LIGHT
GPO - DOUBLE WEATHERPROOF
GPO - SINGLE WEATHERPROOF
PROJECT DESCRIPTION:
BLANK PLATE / JUNCTION BOX PROPOSED DEVELOPMENT
TELEPHONE POINT
DATA POINT
CLIENT:
TELEVISION POINT R KILDEY
HDMI POINT UNIT 1 & UNIT 2 ELECTRICAL
SMOKE ALARM 1 : 100 SITE ADDRESS:
METER BOX LOT 616 RUBY ST
COOROY
HWS HOT WATER SYSTEM
ghwu NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS
GAS HOT WATER UNIT
: SMOKE ALARMS TO BE HARD WIRED IN
WP WATER PUMP ACCORDANCE WITH B.C.A. 3.7.2. DESIGNED BY AUSMAR
: FLOOR WASTE POSITIONS ARE INDICATIVE
LIGHT SWITCH - VARIABLE POLES DRAWN BY A NYOKA
ONLY. FINAL POSITIONS TO BE DETERMINED BY
CUSTOM
2 D LOCAL AUTHORITY PLUMBING REGULATIONS. SCALE JOB CODE
2 - TWO WAY D - DIMMER 1 : 100
: REFER ELECTRICAL PLAN FOR PLACEMENT.
NOTE: ALL LIGHT SWITCHES LOCATED @ 1100mm ABOVE FL.
: ALL EXHAUST FANS TO WET AREAS
D-RK
UNLESS OTHERWISE NOTED,
ALL POWER OUTLETS LOCATED 300mm ABOVE FL. UNLESS TO BE DUCTED TO EAVE (AS PER N.C.C. PART 3.8)
OTHERWISE NOTED & WITH BCA REQUIREMENTS. SHEET 12 OF 29
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.