Council archive · source document
Appendix C - Design Plans · MCU22/0140
Plans and drawings: the text below has words only, no drawings.
ELECTRICAL QUANTITIES NBN CONNECTION LEGEND - INTERNAL
BC - BROOM CUPBOARD
DESCRIPTION No. INSTALL 1x DGPO. C'BD - CUPBOARD
DP - DOWNPIPE
FAN - CEILING FAN ONLY 12 SUPPLY & TERMINATE 1x DATA POINT CAT 6 CABLE. DW - DISHWASHER PROV.
FAN - EXHAUST 8 SUPPLY & TERMINATE 1x PHONE POINT CAT 6 CABLE. FW - FLOOR WASTE
SUPPLY & INSTALL 1x LEAD IN FROM PIT TO SIDE OF HP - HOT PLATE
LIGHT FITTING - DOUBLE SPOT LIGHT 8 HWS - HOT WATER SYSTEM
HOUSE P20 PIPE WITH DRAW WIRE. L - LINEN
LIGHT FITTING - RECESSED LED 71
SUPPLY & TERMINATE THE 2 CAT 6 POINTS IN GARAGE MH - MANHOLE
LIGHT FITTING - SINGLE 35W LED 4 TO 2-GANG SWITCH FOR INTERNAL CONNECTIONS. MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
LIGHT FITTING - WALL MOUNT UP/DOWN 8 PTY - PANTRY
POINT - DOUBLE GPO 56 R - ROBE
REF - REFRIDGERATOR SPACE
POINT - PHONE 4 RH - RANGEHOOD
POINT - SINGLE GPO 20 SH - SHELF
TR - TOWEL RAIL
POINT - TELEVISION POINT 4 TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
SMOKE ALARM 12 WO - WALL OVEN
LEGEND - EXTERNAL
BV - BRICK VENEER
CJ - CONTROL JOINT
SPOT LIGHT FC - FIBRE CEMENT SHEETING
HWS A/C UNIT A/C UNIT HWS SPOT LIGHT
RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
A/C POSTION RBL - RENDERED BLOCKWORK
A/C POSTION SA - SCYON AXON
LED LED
SL - SCYON LINEA
SGPO (300) DW 1000
1000 1000
1000
SM - SCYON MATRIX PANELING
LED LED SS - SCYON STRIA CLADDING
SGPO (1750) RH SGPO (1750) RH
SGPO (300) DW
WB - HARDIES NEWPORT
LED LED
LED
2
LED LED
2
LED
2 2
LED in EAVE LED LED LED in EAVE
2 2
SGPO (1900) REF SGPO (1900) REF
ELECTRICAL LEGEND LED LED
LED LED
LED LED ISSUE
CEILING FAN # DATE DETAILS BY
- 23-07-21 CONCEPT ISS. DC
- 06-08-21 CONCEPT ISS. A JS
CEILING FAN / LIGHT COMBINATION SGPO IN CEILING FOR SGPO IN CEILING FOR LED - 10-09-21 NHP ISSUE AN
2
ANTENNA BOOSTER ANTENNA BOOSTER 27-09-21 WD ISSUE JB
2
LED LED LED
EXHAUST FAN M/H 555X555 M/H 555X555
LED LED
HEAT FAN & LIGHT
WALL MOUNT
LIGHT POINT - CFL (32w / 22w) WALL MOUNT
B LIGHT POINT - BATTEN 35W LED 35W LED
LED
LIGHT POINT - LED IN CEILING IN CEILING
LED po box 6384 p (07) 5319 1500
EXTERNAL FLOOD LIGHT maroochydore f (07) 5450 6437
A/C POSTION
A/C POSTION
qld 4558 QBCC 1083000
A/C UNIT
LED LED
A/C UNIT
WALL LIGHT
WRITTEN DIMENSIONS TO TAKE
35W LED PRECEDENCE OVER SCALE
GPO - DOUBLE
LED
LED LED ELECTRICAL UNIT
LED
GPO - SINGLE 1000 1000
3-4
GPO - DOUBLE WEATHERPROOF
SPOT LIGHT WALL MOUNT WALL MOUNT SPOT LIGHT
GPO - SINGLE WEATHERPROOF
PROJECT DESCRIPTION:
BLANK PLATE / JUNCTION BOX PROPOSED DEVELOPMENT
TELEPHONE POINT
DATA POINT
CLIENT:
TELEVISION POINT R KILDEY
HDMI POINT
SMOKE ALARM
METER BOX UNIT 3 & UNIT 4 ELECTRICAL SITE ADDRESS:
LOT 616 RUBY ST
COOROY
HWS HOT WATER SYSTEM 1 : 100
ghwu NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS
GAS HOT WATER UNIT
: SMOKE ALARMS TO BE HARD WIRED IN
WP WATER PUMP ACCORDANCE WITH B.C.A. 3.7.2. DESIGNED BY AUSMAR
: FLOOR WASTE POSITIONS ARE INDICATIVE
LIGHT SWITCH - VARIABLE POLES DRAWN BY A NYOKA
ONLY. FINAL POSITIONS TO BE DETERMINED BY
CUSTOM
2 D LOCAL AUTHORITY PLUMBING REGULATIONS. SCALE JOB CODE
2 - TWO WAY D - DIMMER 1 : 100
: REFER ELECTRICAL PLAN FOR PLACEMENT.
NOTE: ALL LIGHT SWITCHES LOCATED @ 1100mm ABOVE FL.
: ALL EXHAUST FANS TO WET AREAS
D-RK
UNLESS OTHERWISE NOTED,
ALL POWER OUTLETS LOCATED 300mm ABOVE FL. UNLESS TO BE DUCTED TO EAVE (AS PER N.C.C. PART 3.8)
OTHERWISE NOTED & WITH BCA REQUIREMENTS. SHEET 25 OF 29
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C - Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.