Original source · versioned page text
MCU21-0134 - Approved Bushfire Management Plan
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn -
APPROVED PLAN
MCU21/0134
NOOSA COUNCIL
24 NOVEMBER 2021
J000864
BUSHFIRE MANAGEMENT PLAN v1
Lot 189 on MCH1261
64 Reserve Street,
POMONA, QLD
For
Michelle Huntley-Walker
November 2021
PO Box 9566 Pacific Paradise QLD 4564 / Email: [email protected]
ABN 60 625 108 625
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 22 pages
Page 2
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
DOCUMENT CONTROL
Document: Bushfire Management Plan v1
Client: Michelle Huntley-Walker
Project Number: J000953
Site: Lot 189 on MCH1261– 64 Reserve St, Pomona
File Ref: C:\CLIENTS\HUNTLEY-WALKER MICHELLE – 64 RESERVE STREET
POMONA\04_REPORTING\02 BMP\Bushfire Management Plan v1 – 64
Reserve St POMONA.docx
Versio Date Distribution Author/s Approved
n
1 11/11/2021 Michelle Huntley-Walker J. Isaacs (B. Env Sc.) Joshua Lee
Environmental Scientist; (B. Sc. AES, mEIANZ)
Joshua Lee - Director
(B. Sc. AES, mEIANZ)
- Director
DISCLAIMER
To the extent permitted by law, North Coast Environmental Services (including its employees, partners and consultants) excludes
all liability to any person for any consequences, including but not limited to all losses, damages, costs, expenses, and any other
compensation, arising directly or indirectly, from using this publication (in part or whole) and any information or material contained
in it.
© 2021 i
Page 3
Bushfire Management Plan v1 NCES REF: J000953 Lot 189 on MCH1261 – 64 Reserve St, Pomona Contents 1 INTRODUCTION 3 1.1 BACKGROUND 3 1.2 STATE PLANNING POLICY BUSHFIRE INTENSITY OVERLAY MAP 3 1.3 DEVELOPMENT PROPOSAL 3 2 SITE DESCRIPTION 4 2.1 GENERAL 4 2.2 TOPOGRAPHY 4 2.3 VEGETATION 5 3 HAZARD ASSESSMENT 9 3.1 SPP FIRELINE INTENSITY CLASS VALIDATION 9 3.2 SPP INTENSITY CLASS VALIDATION 9 4 BUSHFIRE IMPACT REDUCTION MEASURES 12 4.1 GENERAL 12 4.2 ASSET PROTECTION ZONES 12 4.2.1 GENERAL 12 4.2.2 STATE PLANNING POLICY – STATE INTEREST GUIDANCE MATERIAL (NATURAL HAZARDS, RISKS AND RESILIENCE – BUSHFIRE) DECEMBER 2019 12 4.2.3 RADIANT HEAT FLUX SETBACKS (APZ) 13 4.3 WATER SUPPLY 15 4.4 FIRE BREAKS 15 4.5 VEHICULAR ACCESS 15 4.6 LANDSCAPING AND REGROWTH 16 4.7 GENERAL PROPERTY MAINTENANCE 16 5 AUSTRALIAN STANDARD 3959:2018 CONSTRUCTION OF BUILDINGS IN BUSHFIRE PRONE AREAS (AS 3959:2018) SETBACKS 18 6 CONCLUSIONS 19 7 REFERENCES 20 APPENDIX 1 – PLAN OF DEVELOPMENT 21 © 2021 ii
Page 4
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
1 INTRODUCTION
1.1 Background
This Bushfire Management Plan has been prepared to manage the degree of potential bushfire
hazard and associated risk acting on Lot 189 on MCH1261 located at 64 Reserve Street,
Pomona, Qld (herein referred as ‘the site’).
1.2 State Planning Policy Bushfire Intensity Overlay Map
The site is mapped under the State Planning Policy (SPP) (refer to Plate 1) as containing the
following Potential Bushfire Intensity areas:
• High Potential Bushfire Intensity area; and
• Potential Impact Buffer.
Plate 1 – SPP Bushfire Intensity Mapping Overlay
1.3 Development Proposal
The applicant is seeking to construct a primary dwelling in the western site extent. The Plan of
Development is included as Appendix 1. The dwelling is proposed within the NC Bushfire Overlay
hence triggers an Material Change of Use application which in turn triggers the need for this
Bushfire Management Plan (Noosa Council 2021).
© 2021 3
Page 5
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
2 Site Description
2.1 General
The site covers 1.58ha and is flanked by Reserve Street along the western boundary. The
majority of the site is characterised by native vegetation dominated by open forest species.
The site is zoned as Rural Residential within the Noosa Plan 2020.
Plate 2 depicts the site’s extent and position in the landscape.
Plate 2 – Site Context (Source: Nearmap 2021)
2.2 Topography
The slope of the land is a major determinant of fire behaviour, particularly the slope of the land
under vegetation that contributes to bushfire hazard. Fire burns faster as it travels up slope, via
preheating of unburnt fuels ahead of the fire, increasing the rate of spread and fireline intensity.
Conversely, fires move more slowly as they travel downslope. Fireline intensity (kW/m) is a
function of the rate of spread (QFES 2019).
The landform declines from west to east through the site with gradual slopes of approximately 1º
recorded. The effective slopes are upslope to the west, across slope to the north and south and
downslope to the east.
Plate 3 depicts topography conditions within and adjacent to the site.
© 2021 4
Page 6
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
Plate 3 – Site Topography (Source: NC Interactive Maps)
2.3 Vegetation
The following vegetation hazard classes (classified in accordance with QFES (2019)) were
identified within the site:
• Vegetation Hazard Class 8.1 – Wet eucalypt tall open forest; and
• Vegetation Hazard Class 9.1 – Moist to dry eucalypt open forests on coastal lowlands
and ranges.
The distribution of observed VHC’s is detailed in Plan BAL01- Vegetation Hazard Classes.
© 2021 5
Page 7
LEGEND \ , 100m BUFFER Vegetation Hazard Class 8.1 Wet eucalypt tall open forest VHC 9.1 Vegetation Hazard Class 9.1 Moist to dry eucalypt open forests on coastal lowlands ani (Leonard et. al (2017) (A3) 1:2000 North Coast i — en REV Environmental PO Box #568 Pacitc Peradse. as. sse4 | BUSHFIRE ATTACK LEVEL ASSESSMENT a,b. 1504 MICHELLE HUNTLEY-WALKER VEGETATION HAZARD CLASSES J000953 BALO1 Services me aencenezs 08625 | 4 RESERVE STREET, POMONA rea =, . eateries ous 1:2000 @ Aa
Page 8
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
The observed vegetation types within and adjacent to the site and their underlying effective slopes
are described in Table 1.
Table 1 – Vegetation Types and Slope
Direction North South East West (onsite) West (offsite)
AS3959 Type A – Forest Type A – Forest Type A – Forest Type A – Forest Type A – Forest
Vegetation
Type
Tall Flooded Tall Flooded gum Tall Flooded gum Regrowth open Tall Flooded gum
Vegetation gum open open forest open forest forest open forest
Description forest Height: >30m Height: >30m Height: 15-22m Height: >30m
Height: >30m
Canopy – Canopy – Canopy – Canopy –
Canopy – T1 – Eucalyptus T1 – Eucalyptus Eucalyptus T1 – Eucalyptus
T1 – grandis, grandis, grandis, grandis,
Eucalyptus Eucalyptus Eucalyptus Eucalyptus Eucalyptus
grandis, propinqua, and propinqua, and tereticornis, propinqua, and
Eucalyptus Corymbia Corymbia Lophostemon Corymbia
propinqua, and intermedia intermedia confertus, intermedia
Corymbia T2 – T2 – Lophostemon T2 –
intermedia Lophostemon Lophostemon suaveolens, Lophostemon
T2 – confertus and confertus and Corymbia confertus and
Lophostemon Lophostemon Lophostemon intermedia, and Lophostemon
confertus and suaveolens suaveolens Eucalyptus suaveolens
Lophostemon propinqua
suaveolens Mid storey – Mid storey – Mid storey –
Polyscias Polyscias Mid storey – Polyscias
Mid storey – elegans, elegans, Juvenile Canopy elegans,
Polyscias Melaleuca Melaleuca spp., Melaleuca Melaleuca
elegans, quinquenervia, quinquenervia, quinquenervia, quinquenervia,
Melaleuca and Wattle spp.. and Wattle spp.. and Wattle spp.. and Wattle spp..
quinquenervia,
and Wattle Understorey – Understorey – Understorey –
spp.. Lantana camara, Understorey – Ottochloa Lantana camara,
Ochna serrulata, Lantana camara, gracillima, Ochna serrulata,
Understorey – Ottochloa Ochna serrulata, Pteridium Ottochloa
Lantana gracillima, Ottochloa esculentum, gracillima,
camara, Ochna Cordyline rubra, gracillima, Ardisia crenata, Cordyline rubra,
serrulata, Smilax australis, Cordyline rubra, and Cordyline Smilax australis,
Ottochloa and Doodia Smilax australis, rubra and Doodia
gracillima, aspera and Doodia aspera
Cordyline rubra, aspera
Smilax
australis, and
Doodia aspera
8.1 Wet 8.1 Wet eucalypt 8.1 Wet eucalypt 9.1 Moist to dry 8.1 Wet eucalypt
QFES 2019 eucalypt tall tall open forest tall open forest eucalypt open tall open forest
Vegetation open forest forests on costal
Hazard Class Combined Combined lowlands and Combined
and fuels loads Combined Surface Fuels Surface Fuels ranges Surface Fuels
Surface Fuels 31t/ha 31t/ha 31t/ha
31t/ha Total Fuels Total Fuels Combined Total Fuels
Total Fuels 35t/ha 35t/ha Surface Fuels 35t/ha
35t/ha 21t/ha
Total Fuels
24.2t/ha
Underlying 1 degree 1 degree across 1 degree 1 degree upslope 1 degree upslope
Effective Slope across slope slope downslope
Plate 4 depicts typical conditions in the observed VHC 8.1 Wet eucalypt tall open forest and Plate 5
depicts typical conditions in the observed VHC 9.1 Moist to dry eucalypt open forest.
© 2021 7
Page 9
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
Plate 4 – VHC 8.1 – Type A Forest to the north, south, east, and west (offsite)
Plate 5 – VHC 9.1 – Type A Forest in the west of the site
© 2021 8
Page 10
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
3 HAZARD ASSESSMENT
3.1 SPP Fireline Intensity Class Validation
An assessment has been undertaken to validate the SPP High Potential Bushfire Intensity Class
mapped across the site. Table 2 details the SPP Potential Bushfire Intensity classes and their
corresponding potential fire-line intensity (kW/m) values as prescribed within Leonard et. al. 2017
and QFES 2019.
Table 2 - Potential Bushfire Intensity classes
The Potential Bushfire Intensity Class is primarily influenced by slope conditions (i.e., topography)
and vegetation type fuel loads.
3.2 SPP Intensity Class Validation
Based on observed conditions, the SPP mapping correctly maps VHC 8.1 as the applicable
vegetation class on the site, however, neglects the narrow band of VHC 9.1 in the western site
extent. The assigned high potential fire line intensity class is accurate for the VHC 8.1 area given
the across slope conditions but is expected to be exaggerated for the VHC 9.1 area.
Flamesol modelling was subsequently undertaken to validate the potential fire line intensity based
on the point of reference slope conditions underlying the hazardous vegetation. Table 3 summarises
the input data used:
Table 3 – Input Data
Input Parameter Input Data
Type A – Forest
AS 3959 Vegetation Type
QFES Vegetation Hazard Classes and Fuel 8.1 Wet eucalypt tall open forest
Loads (31 t/ha combined surface and 35 t/ha total fuels)
9.1 Moist to dry eucalypt open forests on coastal lowlands
and ranges
(21 t/ha combined surface and 24.2 t/ha total fuels)
Effective slope(s) under the classified 1 degree all directions
vegetation type
Flame Width 100m all directions
A QFES Forest Fire Danger Index (FFDI) 47 has been used as assigned by QFES (refer to Plate
6)
© 2021 9
Page 11
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
Plate 6 – Redi Map (QFES FFDI 2019)
The Flamesol output for the anticipated conditions about the site is shown in Plates 7 and 8.
Plate 7 – VHC 8.1 to the north, south, east, and west (offsite) - 1-degree slope – 100m flame width (Source: FPA
Australia)
© 2021 10
Page 12
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
Plate 8 – VHC 9.1 to the west (onsite) - 1-degree slope – 30m flame width (Source: FPA Australia)
The bushfire model output results identify that the VHC 8.1 produces a fireline intensity of 33,875
kW/m irrespective of flame width and therefore represents a High Potential Bushfire Intensity class
under the SPP (i.e., 20,000 – 39,999 kW/m).
The VHC 9.1 produces a fireline intensity of 15,866 kW/m irrespective of flame width and therefore
represents a Medium Potential Bushfire Intensity class under the SPP (i.e., 4,000 – 19,999 kW/m).
© 2021 11
Page 13
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
4 BUSHFIRE IMPACT REDUCTION MEASURES
4.1 General
The following section describes bushfire impact reduction measures to be incorporated into the
proposed development to reduce the risk of bushfire impacts to people and property. Implementation
of the identified measures is not implied nor intended to advocate that building occupants remain on
the site during a bushfire event, nor that people and property will be protected from bushfire impacts.
The measures are intended to reduce the potential severity of bushfire impact to the development
and not prevent bushfire impact. The bushfire mitigation measures have been derived from:
• Department of State Development, Manufacturing, Infrastructure and Planning’s State
Planning Policy – State interest guidance material – Natural hazards, risk and resilience –
Bushfire (December 2019) (referenced herein as SPP (Bushfire) 2019); and
• Queensland Fire and Emergency Services. (2019). Planning for Bushfire Resilient
Communities.
4.2 Asset Protection Zones
4.2.1 General
Asset Protection Zones (APZ) provide a defensive tool to assist in the reduction of potential bushfire
impact to people and property situated in bushfire prone areas. For illustrative purposes, Plate 9
depicts the concept of an APZ surrounding a dwelling in a bushfire prone areas.
Plate 9 – Asset Protection Zones
The development has been confirmed to be located within a bushfire hazard area hence provision
of adequate separation between the proposed works and the hazardous vegetation located on all
sides is required to provide a reasonable level of safety to site occupants and emergency services
staff.
The configuration of APZ’s is typically determined based on the results of the site-specific hazard
assessment including risk of bushfire impact, flame length analysis, potential AS3959-2018 Bushfire
Attack Levels and SPP Bushfire 2019 Assessment Benchmark setback requirements (Refer section
4.2.3)
4.2.2 State Planning Policy – State Interest Guidance Material (Natural Hazards, Risks and
Resilience – Bushfire) December 2019
Assessment Benchmark 4 of the State Planning Policy – state interest guidance material references
benchmark separations for new developments however for consistency, can be used to ascertain
suitable separations for new buildings on existing lots.
Assessment Benchmark 4 states:
Development supports, and does not hinder, disaster management response or recovery capacity
or capabilities. Where reconfiguring a lot creating lots of greater (or less) than 2000 square metres:
To ensure emergency access and operational space for firefighters the subdivision layout results in
© 2021 12
Page 14
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
lots that are sited so that they are separated from the closest edge to the adjacent medium, high or
very high potential bushfire intensity area by a distance that achieves a radiant heat flux level of 29
kilowatt per square metre or less at:
1. The building envelope, if identified at RaL stage, or
2. Where a building envelope is not identified, at all the lot boundaries.
Compliance with Assessment Benchmark 4 can be attained where the proposed building envelope
is sufficiently separated from the nearby forest hazard so that a radiant heat flux level at any point
on the building envelope, does not exceed 29 kW/m². In this instance a specific building footprint is
proposed hence the limit of the building footprint can be used in lieu of a building envelope.
4.2.3 Radiant Heat Flux Setbacks (APZ)
Determination of the setbacks required to satisfy Assessment Benchmark 4 can be identified from
the quantitative modelling output presented in Section 3.2 herein. The output results from Plate 8 &
9 can be used to identify the setback requirements to achieve the <29 kW/m² radiant heat flux SPP
requirement. The required setbacks are shown in Table 4.
Table 4 – Radiant Heat Flux Minimum Setbacks to secure <29kW/m²
VHC Direction <29 kW/m² Setback*
(m)
and slope (º)
8.1 North, South, East (1) 17.9
9.1 West (1) 11.7
* Source – Flamesol Minimum Distance Calculator Plate 8 & 9
Table 4 identifies a minimum setback of 17.9m to the north, south, and east and 11.7m to the west
is required to expose the building to <29 kW/m² radiant heat flux.
It is therefore recommended the proposed works are provided with a minimum 17.9m setback to the
VHC 8.1 vegetation to the north, south and east, and a minimum 11.7m setback to the VHC 9.1 to
the west to achieve an acceptable level of risk under the SPP. The extent of the recommended APZ
is detailed in plan BAL02 – Separation Requirements.
© 2021 13
Page 15
25 5 75 10 125 (A1) 1:250 25
ete
(A3) 1:00
North Coast a om ;
— Environmental Po Box o588 PaitePeradee cx se | BUSHFIRE ATTACK LEVEL ASSESSMENT MICHELLE HUNTLEY-WALKER SEPARATION REQUIREMENTS J000953. BALO1 A |)
Yee ceS cae saweoaeteee |64 RESERVE STREET, POMONA [ese sero “ooo coset a ies WD
jo PTH TE ATM EOHERT OF NEES
a REV [ean
(SSUE OCTALS CATE INT Greco
Page 16
Bushfire Management Plan v1 NCES REF: J000953 Lot 189 on MCH1261 – 64 Reserve St, Pomona 4.3 Water Supply The availability of a reliable water supply for firefighting purposes is a vital tool in the defence of bushfire impact. Reticulated water supply is currently not available within the site. The proposed development will therefore require provision of a readily accessible on-site emergency static water supply in accordance with Assessment Benchmark 4 of the SPP Bushfire 2019. Assessment Benchmark 4 references the QFES 2019 Bushfire resilient communities document for information regarding appropriate static water supply. Section 9.1 of Bushfire resilient communities’ states: An appropriate static water supply (in bushfire prone areas where reticulated supply is not provided) to support effective emergency services response includes a water tank that is available solely for firefighting purposes and can be accessed by firefighting appliances. The water tank is to be provided within 10 metres of each building (other than a class 10 building), which: a) is either below ground level or of non-flammable construction; b) has a take-off connection at a level that allows the following dedicated, static water supply to be left available for access by firefighters: i.10,000 litres for residential buildings; It is therefore recommended that a dedicated 10,000 litres should be made available to the proposed new dwelling. Note that the above recommended water supply volumes should be a static water supply. The volume should be reserved for fire fighting purposes only. Plate 10 outlines an example of how this can be achieved. Plate 10 – Example Static Water Supply tank design for fire fighting purposes (Source: Kingspan Group 2021) 4.4 Fire Breaks The provision of fire breaks and fire trails within a site located in a bushfire prone area offers an important bushfire defence measure to assist in reducing the risk and severity of bushfire ingress onto and through a site. It is recommended a trafficable fire trail is provided around the inner perimeter of the recommended APZ and which connects to the driveway to allow for safe access and egress and operational space for fire-fighting vehicles. 4.5 Vehicular Access Development in bushfire prone areas should be serviced by safe access/exit points for both occupants and emergency services personnel. The development is to be serviced by a single access driveway connecting to Reserve Street to the west. The total length of the proposed road is approximately 100m and will generally be constructed on flat ground. The proposed driveway will be © 2021 15
Page 17
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
located adjacent to Reserve Street and the cleared powerline easement, therefore the risk of
access/egress becoming constrained during a bushfire event is deemed low.
It is recommended the driveway is built to a minimum of 3.5m width in accordance the QLD Fire
Hydrant and Vehicle Access Guidelines 2019 and a passing bay be provided about the halfway mark
of the driveway. No further driveway recommendations are deemed necessary.
4.6 Landscaping and Regrowth
Existing and future landscaping within the site should avoid increasing the potential for bushfire
hazard. Assessment benchmark 5 of the SPP Bushfire 2019 seeks that the site layout places the
landscape and open spaces within the site between premises and adjacent mapped medium, high
or very high potential bushfire intensity areas. This landscaping and open space comprises
protective landscape treatments that:
1. Comprise only low threat vegetation (for example grassland managed in a minimal fuel condition,
maintained lawns, golf courses and cultivated gardens); or
2. Are designed to ensure a potential available fuel load is maintained at less than 8 tonnes/hectare
in aggregate and with a fuel structure that remains discontinuous.
To reduce the potential for bushfire impact to buildings, structures and occupants as a result of future
regrowth and landscaping works within the site, it is recommended:
• The vegetative conditions within the nominated APZ satisfies Assessment Benchmark 5 of
the SPP Bushfire 2019, including the low threat vegetation criteria prescribed in section
2.2.3.2 of AS 3959:2018 or later iterations thereof. This generally entails:
o Removal of surface and near surface fuels (i.e., leafs and twigs and branches) and
understorey shrubs and replacement with lawn, dirt or gravel or a combination
thereof. Retention or installation of discrete clumpings of surface and understorey
fuels/plants is acceptable as long as they do not offer continuous fuels load pathways
from the forest to the building.
o Low hanging canopy and mid canopy foliage should also be removed to
approximately 3-4m height above ground level and no limbs are to extend to within
6m of the roof line of the buildings. All pruning should be undertaken in accordance
with AS 4373 Pruning of amenity trees. Note large trees do not need to be removed
however we recommend no trees or shrubs are retained within 10m of the building
for safety purposes and to separate potential crown fire from structures;
• No woody mulch is used within 2m of buildings;
• Future landscaping works/plantings maximise the use of locally indigenous, low flammability
species and or low-density plantings of suitable open forest /woodland species with low bark
shedding characteristics. Landholders should consult their local native plant nursery for
suitable species selection.
The recommended APZ is required to be maintained by the individual landholder/s and or occupants
and is to consist of low threat conditions in perpetuity.
4.7 General Property Maintenance
The undertaking of an appropriate level of property maintenance throughout the year, and in
particular prior to the fire season, can significantly reduce the severity of fire impact upon a site.
Queensland Fire and Emergency Services recommend the following general actions be undertaken
to prepare for the fire season:
Structure
• Clear leaves, twigs, bark and other debris from the roof and gutters.
• Purchase and test the effectiveness of gutter plugs.
• Enclose open areas under decks and floors.
© 2021 16
Page 18
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
• Install fine steel wire mesh screens on all windows, doors, vents and weep holes.
• Point LPG cylinder relief valves away from the house.
• Conduct maintenance checks on pumps, generators and water systems.
• Seal all gaps in external roof and wall cladding.
Access
• Display a prominent house or lot number, in case it is required in an emergency.
• Ensure there is adequate access to your property for fire trucks - 4 metres wide by 4 metres
high, with a turn-around area.
Vegetation
• Reduce vegetation loads along the access path.
• Mow your grass regularly.
• Remove excess ground fuels and combustible material (long dry grass, dead leaves and
branches).
• Trim low-lying branches two metres from the ground surrounding your home.
Note the above recommendations are that of QFES and are offered herein for advisory purposes.
They have not been set as recommendations for certification purposes.
© 2021 17
Page 19
Bushfire Management Plan v1 NCES REF: J000953
Lot 189 on MCH1261 – 64 Reserve St, Pomona
5 AUSTRALIAN STANDARD 3959:2018 CONSTRUCTION OF BUILDINGS IN
BUSHFIRE PRONE AREAS (AS 3959:2018) SETBACKS
The Bushfire Intensity Overlay Map on the State Planning Policy (SPP) Interactive Mapping System
identifies that the entire site is affected by a High Potential Bushfire Intensity Area and a Potential
Impact Buffer (refer to Plate 1). The build site is therefore located in a designated bushfire prone
area hence the future proposed works must be constructed to satisfy AS 3959.
Building works within Designated Bushfire Prone Areas identified on a power of legislations Hazard
Overlay Map triggers building design assessment under AS 3959:2018. The Standard provides
minimum construction requirements for new habitable dwellings and habitable building alterations in
designated Bushfire Prone Areas. The construction requirements are intended to improve the
performance of buildings subjected to burning debris, radiant heat or flame contact. Building works
in Designated Bushfire Prone Areas must be built to the Bushfire Attack Level (BAL) construction
standard relevant to the building site as identified by the AS 3959:2018 methodology.
A specific BAL assessment has been conducted (NCES 2021) for the proposed development within
the site. The recommended APZ will result is a BAL 29 outcome for the proposed new dwelling
(Refer Section 4.2.3 of this report and BAL02).
© 2021 18
Page 20
Bushfire Management Plan v1 NCES REF: J000953 Lot 189 on MCH1261 – 64 Reserve St, Pomona 6 CONCLUSIONS This Bushfire Management Plan has been prepared to assess and manage the degree of potential bushfire risk acting on the proposed new dwelling for Lot 189 on MCH1261, located at 64 Reserve Street, Pomona. A bushfire risk assessment has identified that the vegetation about the site exposes the proposed dwelling to significant risk of ember, radiant heat and direct flame impact in the absence of additional clearing being provided. The identified risk has been reduced to an acceptable-tolerable level where all recommendations set herein are adopted (i.e. APZ’s). Overall, the development proposed for the site, in combination with recommendations referenced herein, is deemed suitable with respect to providing a reasonable level of protection for people and property within the site. Bushfire is an extremely serious and often unpredictable phenomenon that requires serious preparatory planning and decision making to avoid potential damage to infrastructure and or loss of life. All recommendations made herein have been formulated based on site conditions at the time of writing and therefore may not be appropriate in the event site conditions change over time. Implementation of the bushfire mitigation measures referenced herein is not implied nor intended to advocate that residents remain on the site during a bushfire event nor that people and property will be protected from bushfire impact. The measures are intended to reduce the potential severity of bushfire impact to persons and property and not prevent actual bushfire impact. The landowners and site managers are to be responsible for ensuring the measures prescribed herein are applied and stay up to date with site conditions and industry standards. Landholders/managers should therefore liaise with Queensland Fire and Rescue Services at regular intervals (e.g. recommended at least every 5 years). The first call in the event of a bushfire emergency should always be ‘000’. © 2021 19
Page 21
Bushfire Management Plan v1 NCES REF: J000953 Lot 189 on MCH1261 – 64 Reserve St, Pomona 7 REFERENCES Cruz M.G., Gould J.S., Alexander M.E., Sullivan A.L., McCaw W.L., Matthews S. (2015) A Guide to Rate of Fire Spread Models for Australian Vegetation. CSIRO Land and Water Flagship, Canberra, ACT, and AFAC, Melbourne, Vic, 123pp. Gould, McCaw, Cheney, Ellis & Matthews. (2007). Field Guide – Fuel assessment and fire behaviour in dry eucalypt open forest. Ensis-CSIRO, Canberra, ACT and Department of Environment and Conservation, Perth, WA. Queensland Fire and Emergency Services. (2019). Bushfire Resilient Communities - Technical Reference Guide for the State Planning Policy - State Interest Guideline - Natural Hazards, Risk and Resilience 2- Bushfire. Southeast Queensland Fire and Biodiversity Consortium – Operational Manual. The State of Queensland, Department of State Development, Manufacturing, Infrastructure and Planning (2019). Natural hazards, risk and resilience - Bushfire State Planning Policy – state interest guidance material. Webster. (2002). The Complete Bushfire Safety Book. Random House (Aust) Pty Ltd. © 2021 20
Page 22
Bushfire Management Plan v1 NCES REF: J000953 Lot 189 on MCH1261 – 64 Reserve St, Pomona APPENDIX 1 – PLAN OF DEVELOPMENT © 2021 21
Page 23
Gl, BesSexve SN LOW OO
Scale og Tag and house, sheds iM = ‘mt
\OOOrm TAN CNEORIRA Ov Vp WNAHAS
BW DVovercny Ci\eosina Sov Shes
lw x 1o™%
Eoadrvo ‘ er.
Wouse_ ted 3S mene
_Nrouse le F
Lemoxh 2). 64°
Wrdkhw 16.450
Ackue\ <\cos
ATER
O€:s Jou x tu
ow
Rool\
Cu x?
\Su
@ SAKA Lov Wor eshox
\Wouse_- Cos 5 ‘Tay acy
lO ¥ a.640 Ly Bea®
AG FO
}Ooxw.is aoe é
ISO leasing con
ee WOTIEShe p
— a 3m x V2
> 2 of
[CO 36?
a TVS WAY Koes Not Weed) =
CKesmingy Ho Ateey ‘vse. veak 1S adveudy,
3 creares +
maces Seo’ SOT Khe most vrisalnlag