Attachment C - Stmwater Man Plan · MCU15/0016
Attached to the e-mail MCU15/0016 Response to information request (updated).
Plans and drawings: the text below has words only, no drawings.
375 TO ON SITE-
RETENTION TANKS
AT 1L3.775
150 SUBDRAINAGE TO-
LAWFUL POINT OF
DISCHARGE AT IL3.360
500 FILTRATION LAYER:
SLEEPER RETAINING
}__200 EXTENDED DETENTION DEPTH
WALL OR
EQUIVALENT
4.45 4.410 4.450
—_ +"
SN
THE ENTIRE BRS TO BE WRAPPED
— IN A WATERPROOF LINER
100 TRANSITION LAYER
1.
2.
3.
4.
5.
200 DRAINAGE LAYER
(ALLOW FOR 60mm FALL IN DRAINAGE PIPES)
3.560
ee 3.360
BIO RETENTION SYSTEM (BRS)
CROSS SECTION
SECTION
SCALE NTS
BIO RETENTION SYSTEM LEVEL
SCHEDULE
EDGE OF SURROUND 4.450
WEIR LEVEL BYPASS 4.410
SURFACE LEVEL OF FILTER 4.160
INVERT LEVEL OF FILTER 3.660
TRANSITION LAYER 3.560
INVERT LEVEL OF DRAINAGE 3.360
INVERT LEVEL OF BYPASS 3.775
MAIN DESIGN PARAMETERS FOR BIO RETENTION SYSTEM:
MINIMUM REQUIRED FILTER SURFACE AREA: 65sqm
EXTENDED RETENTION DEPTH: 250mm
DEPTH OF FILTER LAYER: 5S00mm
DEPTH OF TRANSITION LAYER: 100mm
DEPTH OF SUB-—DRAINAGE LAYER: 200-—260mm
NEW HI-FLOW BYPASS CHAMBER DISCHARGING TO RETENTION TANKS
SET OVERFLOW WEIR LEVEL TO 4.410 AND DISCHARGE OVERFLOW DIRECTLY TO
RETENTION TANKS VIA 6375
9375 TO TANKS.
NOTE:
THE ENTIRE TRENCH OF THE BIO RETENTION
SYSTEM SHALL BE WRAPPED WITH AN. IMPERVIOUS:
Ft
2
65sqm BIO RETENTION VEGETATED TREATMENT: -
a
=
=
=
& rN. YN
300 FROM ROOF DRAINAGE.
DRIVEWAY /CARPARK
$375 FROM
BYPASS CHAMBER
DIRECTED TO EXISTING
STORMWATER MANHOLE, LAWFUL
POINT OF DISCHARGE.
ACCESS HATCH REFER
TO MANUFACTURER
SLEEPER RETAING WALL, WHERE
EEQUIRED
BIO RETENTION SYSTEM (BRS'
PLAN VIEW 1:100
ACCESS HATCH REFER
TO MANUFACTURER
DRAINAGE LAYER TOWARDS
cl
USING SCREW CAP.
USE 2+45deg BEND AT
INVERT.
DO NOT USE 90deg BEND!
PIPE IS PERMITTED! SLOTS
SONNECT TO #150
COLLECTOR PIPE, PVC, NO
SLOTS
USE 2e45deg BEND
00 NOT USE 90deg BEND!
TYPICAL #90 SLOTTED PVC WITH
a TO. SURFACE
NOTE:
ONLY PRE_FABRICATED SLOTTED
SLOTYTED PIPE AT 750 SPACING
sd LEAN
= PROVIDE” 1:200 GRADING OF
ay dé / 2 RA
J 2 CHAMBER,
2
“Oy ~
7) e PRODUCED BY HELP OF A
ee, e GRINDER CAN NOT BE
“On, 2 TOLERATED!
BIO RETENTION SYSTEM
4.450 4.450
DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
[Amd Description Date
;
@225 sowmycanon
PIPE AT HIGH LEVEL
100 COMMUNICATION
PIPE AT LOW LEVEL
375 OVERFLOW FIXED
TO WALL WITH SS
BRACKETS
SLOW LEAK WITH #100
ORIFICE PLATE
$375 TO LAWFUL POINT - vee
OF DISCHARGE aes ‘
RETENTION TANK ASSEMBLEY DETAIL
SCALE: NTS
EXISTING 375 RCP
LAWFUL POINT OF DISCHARGE
Issue Notes Date
For Development Approval] X 20-05-15
For Building Approval
For Tender
For Construction
As Constructed
E Hydraulic 3:
\-
contact: Reinhold Koenning MiEAust RPEQ No 7023
PO Box 181
Moffat Beach, QLD, 4551
email: [email protected]
PH: (07) 5491 4333 FX: (07) 5491 4233
CLIENT :
| & L KIPPEN
ARCHITECT :
iS IAN GORTON DESIGN
(PROJECT: 73 RENE STREET
NOOSAVILLE
LIGHT INDUSTRIAL
DRAWING TITLE:
A
STORMWATER
QUALITY & QUANTITY
DETAILS
Design| RK. | checked | Ch [Date 20-05-15 | Dwg, No. AMD,
SCALE : NTS on At uNo.| 3 of 4 2999-3 J
RPD:— LOT 1 SP 244573
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment C - Stmwater Man Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.