Original source · versioned page text
App B - Updated Plans
Attached to the e-mail MCU10/2058 002893 - Minor Change Application - 24 Lionel Donovan Drive.
Plans and drawings: the text below has words only, no drawings.
30000
RP Details
20850 4000 5150 900
Lot 34 on SP170751
150
2600 4200 7350 4400 2000 1000 3000 3600 1100 1500
150 150 150 150
Site Coverage - 45.59% 300
Local Authority - Sunshine Coast 5.465 3.810
Regional Council
Typical 5400 x 2400
Typical 5400 x 2600
Zone Map - ZM8 - Industry 1400
Carparks 9 - 14
setback line
Landscaping
Carparks 2 - 8
Existing Existing
Lionel Donovan Drive
Class 7a and 7b - Carparking and Warehouse
Existing Screened
Carparking
washdown area
Carparking
Existing
Type C - 1 to 2 Storey
Refuse &
4200
Shared
Existing Zone
12 11 10 9 8 7 6 5 4 3 2 1
Schedule of Areas Landscaping
Ground Floor
and Crossover
First Floor 150.3 Existing
setback line
Industrial
6000mm
Proposed
Driveway
Driveway
Total GFA
Lot 34 concrete
6438
6000
paving line of existing roof above
line of existing awning over line of existing awning over
1400 1200 1400
line of existing awning over
dp dp dp path 200
150
150
125
150
4.6x1.2fg 3.0x3.6sw
1100
1000 1000
970 S
765
line of existing awning over
4500x4200rd 4500x4200rd Up
12 1
100
Main
set 00mm
ne
00
G
Exit
14 21
11001
Entry
Exit
k li
970
T
4500x4200rd
125
line of path at ground level
EM
bac
45
100
150
4200
FHR 36
3.0x3.9sw
EMT D
Existing
Driveway
Proposed party wall 90.90.90
870 1175
awning over
Landscaping
concrete
existing
8030
Exit
870
paving
Existing
3.0x3.9sw
Existing Existing Existing
17000
17000
12800
Warehouse Warehouse Warehouse
line of awning over
line of roof over
FE
70
13 14
9690
Existing
Sink
3810
Kitchen
2.1x3.9sw
2740
Existing 1 2
Existing 4.5
Carparking scooter Capped MV
70
Existing Disabled/ Disabled/
870
2290
2150
parks Unisex WC
1500
Unisex WC
Landscaping 870 SF10
900
70
150 50 150
6.5 6.0 5.5 5.0 150
4.090
3000 5000 2440
o/h
1500
setback line
blade wall
2500
Existing Warehouse Building 20733 6260 2500
150 150 70 70 150
13925 32500
Existing Landscaping
Carparking Required - 14
Existing Shared Zone Carparking Provided - 14 Site / Ground Floor Plan
Scooter Provided - 2
Project: Issue-Date-Initial-Revision Title: Drawing #:
cOOL ARcHiTEcTURE USM / Ironman A 3.11.25 - GM - Existing Conditions Existing Conditions EC001
Minor Changes Application to Site / Ground Floor Plan
Phone: 0421 559 769 Warehouse Development at
A3 Scale: Des: GM Project #: Issue:
Lot 34 Lionel Donovan Drive
1:200 Drn: GM 25.001 A
Noosaville Q