Council archive · source document
211119 - Seaview Tce - DA submission · MCU21/0212
Very large file (14.1 MB): the original may take a few minutes to open or download. The page text below is quick to read.
A B C D F site details
E
2750 4990
3000 7500 60 and 66 Seaview Tce,
LOT 4 Sunshine Beach QLD 4567
36000
0
0
00
RP189884
0
00
E
0
00
35
0
00
34
0
00
33
00
32
Lot 96 on RP 81810
31
30
l
hanne
Site Area 576 sqm
E
and c
DN public walkway site boundary | 24.635 m approx | 94° 20' 40"
areas
te kerb
E
36000
concre
proposed new dwelling
2.0m setback
lower ground
internal 178.70 m²
1 se
site boundary | 22.183 m approx | 4° 20' 40"
external - pav 26.40 m²
S
external - pool 23.15 m²
LOT 51 sub total 228.25 m²
LOT 69
RP81810
RP81810
S
ground floor
6660
proposed 2 internal 259.93 m²
Terrace
story dwelling external 26.90 m²
site bounda
external - pav 27.19 m²
S
sub total 314.02 m²
ry | 22.348
2 level 01
Seaview
S
internal 37.21 m²
3220
external 52.54 m²
m approx
sub total 89.75 m²
S
3
| 177° 21'
subtotal internal 475.84 m²
subtotal external 156.18 m²
50"
S
proposed new
total 632.02 m²
6580
driveway
site cover
S
proposed electrical max 40% = 230.43 m²
connection to new dwelling proposed storm
Sw Sw Sw Sw
water infiltration lower ground 219.6 m² / 38.12%
S
4 proposed new
E
2.0m setback ground floor 230.16 m² / 39.95%
0
E
3400
sewer connection
level 01 71.27 m² / 12.37%
10.5m coas
E
E
S S S S S S S S S S S S S S S S S S S S S S S
E sewer pump out line
S
E elec pillar site boundary | 27.345 m approx | 274° 20' 40"
2.0m setback
proposed roof
7.5m setba
0 tal
water run off into
0
E
00
00
E
elec
setback
infiltration tank
30
31
E
E E E E E
notes
S
E power pole
ck
EE E
LOT 68
E
E
E
RP81810 1. All works to be carried out in
34000
00
0
0
0
0
00
00
00
00
accordance with the general
330
E
29
28
27
S
32
E roof ridge approx FFL 35.750 construction notes on coversheet of this
E
package.
2. All works to be carried out in
accordance with the DA and BA
including drawings & conditions.
3. Areas measured to outside face of
walls. External covered area
calculations do not include external
areas under eaves, driveway and
uncovered hardscaping.
legend
S S S S
existing sewer line
Sw Sw Sw Sw
existing stormwater line
E E E E
existing electrical line
T T T T
existing telephone
W W W W
existing water line
note: refer survey for all existing services
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV
PROJECT NO 0375
ac
DL
A
C
24.09.21
20.10.21
schematic design
Prelim DA
66 Seaview Tce, G & C Deane site plan SD 100.00 F SCALE As
indicated
proposed site plan
DL D 01.11.21 DA submission Sunshine Beach
DL F 16.11.21 DA submission schematic design
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
1:1 @ A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
211119 - Seaview Tce - DA submission.pdfRelated documentApplication case desk ↗
About this file
- File size
- 14.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.