Original source · versioned page text
Att 5 - Codes Assessment
Attached to the e-mail Council Road Upgrade, Attachments inc Waste Mgmt Plan & Geotech (Email 2 of 3).MCU17/0054.
S7.3 For power lines that connect to a
premises, the height of plant species at
Figure 14-18 maturity provides for a 2m clearance below
the power line; (see Figure
14-18)
AND
S7.4 Trees and large scrubs are located a
minimum of—
a) 5m from electricity poles and pillars;
b) 4m from street lamps;
c) 2m from stormwater catchment pits;
and
d) 2m from underground services and
utilities;
AND
S7.5 Plants are located to enable
tradespersons to access, view and inspect
service meters, such
as water and electricity meters;
AND
S7.6 Root barriers are installed around
trees that are located within 3m of any
infrastructures or that have potentially
invasive roots.
O9 – Landscape Entry Statements Not Applicable
O8 Tree and plant massing are the dominant S8.1 No solution provided.
features of entry statements to residential or
commercial estates and are integrated with the
landscape theme of the estate and the natural
landscape character of the locality, rather than
the entry being dominated by built elements
such as masonary walls, waterfalls and
assembled rock outcrops. (see Figure 14-19).
O9 Entry statements are low maintenance. S9.1 Landscaped entry statements are low
Figure 14-19 Typical estate entrance maintenance and located entirely within
privately owned land.
Private open space S10.1 For Multiple housing Types 2 and Not Applicable
O10 Private open space is— 4, each dwelling unit provides for
a) provided to all dwelling units and landscaped private open space
accommodation units; comprising—
b) of adequate size and dimensions to suits a) for units at ground level, a minimum
the needs of occupants; area of 25m2 exclusive of the clothes
c) clearly set apart for private use and drying area, with minimum dimensions
separate from communal areas; of 4m and maximum gradient of 1 in
d) directly accessible from a living area of 10 (10%); or
the unit; b) for units above ground level, a
e) located away from noise generating minimum area of 12m2, with minimum
uses; dimensions of 2.5m; or
f) capable of receiving adequate sunlight; c) if small dwelling units within the
and
Business Centre Zone, a balcony not
designed to provide for the privacy of
less than 1.5m depth and with a
occupants of the premises and adjoining
minimum area of 4m2;
premises.
AND
S10.2 For Multiple housing Types 2 and 4, Not Applicable
the private open space area at ground level
is enclosed by side and rear fencing,
screening or dense landscaping and the
landscaping can attain the equivalent of 60%
of the height of the building on maturity to
protect the privacy of residents;
OR
S10.3 For Visitor accommodation no
solution provided Not Applicable
Communal open space - Not Applicable
O11 Communal open space within the
development provides adequate area for
Page 12