Att 5 - Codes Assessment
Attached to the e-mail Council Road Upgrade, Attachments inc Waste Mgmt Plan & Geotech (Email 2 of 3).MCU17/0054.
Specific Outcomes and Probable Solutions for the Business Uses Code
Table 14-8 For all Business Uses
Electricity infrastructure Existing supply is adequate for
O18 The development does not adversely S18.1 No solution provided development on the site. Detailed electrical
impact on existing or future electricity supply design will determine the requirement for
infrastructure; AND any onsite transformers, which can be
conditioned to be screened within an
appropriate area setback from the frontage.
N/A
O19 All uses and works maintain an S19.1 Development for uses adjacent to or
adequate safe distance from electrical within 50m of an existing electricity
infrastructure including substations, substation incorporates noise attenuation
overhead powerlines, power poles and measures to mitigate noise impacts;
transformers.
AND Complies - The building will remain on the
S19.2 Buildings and structures (including site and clear of the existing power lines
swimming pools, sheds, tennis courts and within Earl Street.
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements.
Noise Complies – The site is surrounded by three
O20 Development is designed and sited to No solution provided roads and community uses along the
avoid noise emissions that unreasonably southern boundary. The businesses can
diminish the amenity of the area or operate, undertake waste servicing and
surrounding uses. deliveries without causing any significant
adverse impacts to noise that would
unreasonably diminish the amenity of the
surrounding uses.
The applicant will manage waste and
delivery vehicles to control noise impacts.
Mechanical plant and equipment and
storage areas S21.1 Mechanical plant and equipment Complies – Mechanical equipment can be
O21 Mechanical plant and equipment are— located at the rear of the building more than
(including air conditioning equipment) and a) located more than 2m from any property 2m from neighbouring community uses in
storage areas are designed and located to— boundary; such a way as to not be visible to
a) avoid adverse visual impacts when b) where located at ground level, screened surrounding residential properties.
viewed from the street and adjoining by fencing 1.5m in height or dense
properties; and vegetation of at least 1.5m in width
b) visually integrate with the building incorporating grouped trees and shrubs with
design. maximum separation distance of 1m
measured from the centre of the tree or
scrub; and
c) are visually integrated into the line and
plane of the building and roof design and do
not project beyond the height or width of the
building when viewed from the street and
adjoining properties; AND
S21.2 For Industrial business and Retail Not applicable
business Type 3, materials stored outside
of a building do not exceed 4m in height or
half the height of the on-site buildings
whichever is the greater.
Safety and security
O22 All property boundaries are clearly S22.1 Boundaries are identified by such Complies – Existing boundaries clearly
identifiable with public and private spaces means as - identified by landscaping and changes in
clearly defined. a) fencing; or grades to the carparking areas.
b) changes in surface materials or levels; or
c) landscape treatments;
AND
S22.2 Loading and storage areas are well lit Complies – Back of house and bin areas
or can be locked after hours. can be locked after use.
S23.1 All premises are identified by the
provision of the street number in a prominent Proposal able to comply
location, preferably near the site entry, (i.e.
on the kerb or letterbox or by signage on the
building or site).