DETAILED LANDSCAPE DOCUMENTATION
65-67 ELANDA STREET, SUNSHINE BEACH Q
LANDSCAPE SPECIFICATION 2.4 Compost and Fertiliser
Compost
diameter. Keep organic and inorganic mulch not closer than 50mm from plant stems.
Depths: Spread organic mulch to the nominated depth or a minimum depth of 100mm.
NOTES General: Provide well rotted vegetative material or animal manure, free from harmful chemicals,
grass and weed growth as per AS 4454.
6.0 PLANT SUPPORT
Fertiliser 6.1 Stakes and Ties
1.0 GENERAL General: Apply Agriform or similar slow release tablets at the following rates. Stakes
1.1 Standards Trees 4 Tablets. Shrubs 3 Tablets. Ground covers 1 Tablet. Add a handful of Dynamic Lifter Requirement: Generally, plants of good quality should be self-supporting, however stake plants
and water in well each 4 weeks during the establishment period. Fertilize turf areas with located in open ground or adjacent to vehicular traffic or as directed to mark their location or
§ Soils to comply with AS 4419-2003 - Soils for Landscaping and Garden Use.
Dynamic Lifter at the rate of 250 grams per 5 m2. provide additional protection.Material: Hardwood, straight, free from knots or twists, pointed at
§ Compost, soil conditioners and mulches to comply with: to AS 4454. one end.
§ AS 4970 - Protection of trees on development sites 3.0 PLANTS Installation: Drive stakes into the ground for at least a fifth of their length, avoiding damage to
§ AS 4377 - Pruning of Amenity Trees the root system. Place stake at a clear distance of 50mm from the edge of the rootball.
§ NATSPEC reference book: Specifying Trees - a guide to assessment of tree quality 2003 by 3.1 General Plants 2.5m high: Three 50x50x2400mm stakes per plant.
Ross Clark General: Provide plants with the following characteristics: Plants 1.0 - 2.5m high: Two 40x40x1800mm stakes/ plant.
§ Large healthy root systems, with no evidence of root curl, restriction or damage. Plants 1.0m high: One 30x30x1200mm stake per plant.
2.0 SITE AND SOIL
2.1 Preparation
§ Vigorous, well established, free from disease and pests, of good form consistent with the
species or variety.
Ties CONTEXT MAP
General: Provide hessian or equivalent non-abrasive ties fixed securely to the stakes, REFERENCE SCALE
Weed eradication § Hardened off, not soft or forced, and suitable for planting in the natural climatic conditions preferably one tie at no more than one-third of the main stem, others as necessary to stabilise
Herbicide: Eradicate weeds using environmentally acceptable methods, such as a non-residual prevailing at the site. the plant.
glyphosate herbicide in any of its registered formulae, at the recommended maximum rate. Supply: Supply plants that are propagated in a nursery facility that have been accredited by the
Manual removal of weed undergrowth: Regularly remove, by hand, rubbish and weed growth Nursery Industry Association of Australia 7.0 IRRIGATION
throughout grassed, planted and mulched areas. Remove weed growth from an area 750mm
diameter around the base of the trees in grassed areas. Continue eradication throughout the
Replacement: Replace damaged or failed plants with plants of the same type and size. 7.1 General DRAWING REGISTER
course of the works and during the planting establishment period. 3.2 Plant Containers and Stock Sizes Install automatic irrigation to all common areas, and individual tap computers to private
Vegetative spoil General: Supply plants in weed free containers of the required size. courtyards where applicable. Water to be pump fed from on site rain-water tanks connected to Drawing No. Drawing Title Issue
down-pipes and storm-water system.
Remove vegetative spoil from site. Do not burn.
20-00902-CS01 COVER SHEET B
Site topsoil 4.0 PLANTING
20-00902-LP01 LANDSCAPE LAYOUT PLAN B
Remove Strip topsoil from known areas of construction and stockpile in an appropriate area so 4.1 General 8.0 COMPLETION
that drainage and construction is not restricted. Make sure that the soil cannot flow out of the 20-00902-LP02 GROUND FLOOR PLANTING PLAN B
Individual tree stock in grassed areas and planting in beds: Excavate a hole to at least twice the
site in a storm situation and infiltrate the storm water system. Erect silt barriers to protect S/W
system.
diameter of the rootball and at least 1.5 times deeper than the rootball. Break up the base of 8.1 Planting Establishment 20-00902-LP03 ROOFTOP LANDSCAPE PLAN B
the hole to a further depth of 100mm, and loosen compacted sides of the hole to prevent
Establishment Period
2.2 Subsoil confinement of root growth. 20-00902-LP04 TYPICAL LANDSCAPE DETAILS B
Commencement: The planting establishment period commences at the date of practical
Cultivation 4.2 Watering completion inspection. Unless nominated differently continues for a minimum period of 12 20-00902-LP05 PLANTING SCHEDULES B
Cultivation depth to existing subgrade: 150mm unless specified otherwise. Requirement: Thoroughly water the plants before planting, immediately after planting, and as weeks or until the works are accepted on-maintenance by the Local Council Authority.
Cultivation depth to garden areas: 300mm unless specified otherwise. required to maintain growth rates free of stress. Existing planting and grass
Cultivation depth to turf and grass areas: 100mm unless specified otherwise. Watering basins for plants in grass: Except in irrigated grassed areas and normally moist areas Where existing grass or planting is within the landscape contract area, maintain it as for the
and impervious subsurface strata, construct a watering basin around the base of each corresponding classifications of new grass or planting.
Services and roots: Do not disturb services. Keep clear of tree roots in drip zone. Cultivate by
hand if necessary.
individual plant, consisting of a raised ring of soil capable. LANDSCAPING CALCULATIONS
Recurrent works
2.3 Topsoil 4.3 Placing Throughout the planting establishment period, carry out maintenance work including watering, SITE AREA GROUND FLOOR ROOFTOP
Remove the plant from the container with minimum disturbance to the rootball. Ensure that the mowing, weeding, rubbish removal, fertilising, pest and disease control, reseeding, returfing,
Source
rootball is moist and place it in its final position, in the centre of the hole and plumb, and with staking and tying, replanting, cultivating, pruning, hedge clipping, aerating, reinstatement of
General: Import topsoil unless the topsoil type can be provided from material recovered from
1020m2 464m2 45.5% 308m2 30%
the topsoil level of the plant rootball level with the finished surface of the surrounding soil. mulch, renovating, top dressing, and keeping the site neat and tidy.
the site.
4.4 Fertilising Replacements
Placing topsoil
In planting beds and individual plantings, place fertiliser pellets around the plants at the time of Continue to replace failed, damaged or stolen plants. Replacement plants are to match the
General: Spread the topsoil on the prepared subsoil and grade evenly, making the necessary planting. species and sizes outlined in the planting schedule. GROUND FLOOR HARD SOFT
allowances to permit the following:
54.5 Backfilling Grassed areas LANDSCAPING LANDSCAPING LANDSCAPING
§ Achieve required finished levels and contours after light compaction.
Commence grass maintenance works at the completion of sowing,
§ Finished surface levels of grassed areas to be flush with adjacent hard surfaces such as Backfill with topsoil mixture. Lightly tamp and water to eliminate air pockets. Ensure that 151m2 313m2
topsoil is not placed over the top of the rootball, so that the plant stem remains the same height hydroseeding and turfing. Maintain healthy weed free growth. Grass coverage must achieve at 464m2
kerbs, paths and mowing strips.
above ground as it was in the container. least 80% at the time of practical completion. 32.5% 67.5%
Finished surface levels of mulched areas to be 25mm below adjacent pathways, kerb or the
like.
Consolidation
5.0 MULCHING
5.1 General
PP
SEWER LINE
Compact lightly and uniformly in 150mm loose layers. Avoid differential subsidence and RETAINING WALL 89°56'36"
PROPERTY BOUNDARY 33.544M | 89° 56' 36"
7000L TANK
excess compaction. Produce a finished topsoil surface that has the following characteristics: General: Organic Mulch shall be free from stones, soil, clay, dust, weeds, seeds, roots, sticks, RL 43140 RL 43140
179°58'36"
ENTRY
190mm STEP
§ Finish to design levels. rubbish, vermin, insects, pests, fungus, disease and other deleterious material. It shall be free LEISURE BED RL 52320
PROPERTY BOUNDARY 15.091M | 359° 59' 36"
RL 43140
from matter toxic to plant growth. GARAGE
H4
BALCONY
§ Smooth and free from stones or lumps of soil.
359°59'36"
RL 43330 UP
STREET
STREET
BATH BED
Type: Mulch shall be Natramulch or Hoop Pine Fines LIFT
§ Graded to drain freely, without ponding or concentration of flows to catchment points.
PROPERTY BOUNDARY 15.091M | 179° 58' 36"
SEWER
LIFT
5.2 Organic Mulch Installation
CONNECTION
POINT
RL 43455 BATH BED
§ Graded evenly into adjoining ground surfaces. 1:8
1:6 1:8
GARAGE
UP
H3 BALCONY
RL 43330 SEWER MH SL41.8
RL 447
§ Ready for planting. General: Place mulch to the required depth, clear of plant stems, and rake to an even surface 73
190mm STEP
RL
LEISURE
43140 BED RL 52320
flush with the surrounding finished levels. Spread mulch to the specified thickness so that after RL 44540
ENTRY
RL 42940 190mm STEP
ENTRY
Topsoil depths SEWER
settling, it is smooth and evenly graded between design surface levels sloped towards the base ENTRY CONNECTION
179°58'36"
ELANDA
ELANDA
POINT
3.138 RL 52120
LEISURE BED
Planting areas generally: As specified otherwise 300mm. of plant stems in plantation beds.
RL 42940
Telstra Pit GARAGE H2 BALCONY
359°59'36"
RL 42940
Grassed areas generally: As specified otherwise 150mm. In mass planted areas: Place after the preparation of the planting bed but before planting and
UP
BATH BED
29' 29"
| 197°
1:6 1:8 LIFT
other work. 1:8
93M
Tree pits: As specified otherwise 800mm.
RY 13.5
RL 43065 LIFT
NDA
TY BOU
RL 442 BATH BED
In smaller areas (e.g. planter boxes): Place after the preparation of the planting bed, planting
55
Podium and containterized planters: As specified otherwise, 1000mm for small trees, 600mm
PER
UP
PRO
GARAGE
PROPERTY BOUNDARY 16.098M | 359° 59' 36"
RL 42940
H1
for medium to screening shrubs, and 300mm for small shrubs and ground covers. and other work. RL 42940
9"
LEISURE BED RL 52120
29'2
Extent: To surrounds of plants planted in grass areas, provide mulch to a minimum of 600mm RL 43940
ENTRY
197°
UP ENTRY PATH
RL 42940
7000L TANK
PROPERTY BOUNDARY 29.463M | 269° 56' 38"
269°56'38"
R LINE
SEWE
GROUND FLOOR LANDSCAPING ROOFTOP LANDSCAPING
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: COVER SHEET
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-CS01 B
scale:
- Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP REFERENCE PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - COVERSHEET refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT 2021
© Openspace Architecture 2021 abn 91 651 947 240
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 6 sections
Section 2
ROAD CROW
.08 .40 1 71 .69 .19 .79
.85 46 52 51.0 3.95 510.
R52.67
45 .39 55 55 51
.5
45 .0 4
47 54 52..77
30 5
54
.9 2 SECOND LEVEL .14 R52.48 POOL/DECK
45
Top 51.71
Bot 50.84
4.9 47
Window
PP 5.27 .55LOWER
K&C
. 0 5 AREA
50 5 7
SEWER LINE
4 7 WALL
4
43.0
REINSTATE TURF TO PUBLIC VERGE D44.70
1076
.89 91 GARDEN 5 45.12
42.5
D44.69
471
.0
To full width of public verge excluding 1 45 . 3 9 7 1 LEVEL 74 70
45
.74 . 3 0 BOUNDARY .91 9 .26 61
.8 455.73 45 45.2 .7 .7 RETAINING WALL . 89°56'36"
43.5
44 TIMBER PAILING FENCE43.6 . 2
41. 41. 41.1.11
PROPERTY 33.544M | 89° 56' 36"
45
footpaths
45 0 4 4444 42 42 42
. 8 OUTSIDE 4
45
TE
.25 7000L TANK
PROTECT EXISTING TREES
0 45 EA EA 5
NEW CONCRETE FOOTPATH
4 5 .7
.7 6 WALL 41. Retain and protect existing mature
Install 1.5m wide broom finished concrete 45 RL 43140 RL 43140
39 trees on adjoining property. Refer
6 4.64 41.
179°58'36"
footpath to local council requirements .
0 0
Specification Notes
4545
.95 00
ENTRY
.36
42 42.
45
OW OW
190mm STEP
+T +B
.49 0
LEISURE BED
9 TREE
TE
EXTENT OF NEW BITUMEN 5.5 4545.4
PROPERTY BOUNDARY 15.091M | 359° 59' 36"
Ht = 8
Infill bitumen and install new kerb and 4 RL 43140 Spread = 15.0
TILES .72
channel to match and align with adjoining Trunk = 0.60
TE
property frontage. To future engineering H4 43 Type = NR
.6 1
600 WIDE SCOUR
GARAGEPROTECTION
45 and in accordance with local
design BFC .24 BALCONY
2760 3240
45 Select 70-150mm pebble treatment
BUP100
359°59'36"
council requirements RL 43330
over suitable weed matting UP
4
TE
+ RL 42.950 3
BATH BED 41. PRIVATE COURTYARDS- UPPER
5 SYN TERRACE Tiled balcony on
.4
.5
45
TE
TIMBER PAILING FENCE
LIFT concrete slab and synthetic turf
45
DRIVEWAY CROSSOVERS area on stabilized sand layer.
5m wide select exposed aggregate
PROPERTY BOUNDARY 15.091M | 179° 58' 36"
.42
concrete to local council requirements
LIFT SEWER
45 CONNECTION
POINT
STREET
RL 43455 BATH BED +B PRIVATE COURTYARDS - LOWER
TILES OW TERRACE Mulched garden beds with
.07
+T
1:6 1:8 UP
OW
45
42
EA
1:8
H3 .00 tiered planting arrangement. Refer
EA
42
GARAGE BALCONY 0
.95
Planting Plan LP02 for detailed
0
RL 43330 + RL 42.950 SEWER MH SL41.8 planting design and schedule
RL 4
4773 TREE
Ht = 7
190mm STEP Spread = 7.0
wer M/H LEISURE
RL 43140 BED Trunk = 0.30
S .10 0
Records 45 45.1 RL 44540 52
Type = PALM
41.
RL 42940 190mm STEP SEW
GRASSED ENTRY ENTRY ER
LIN
2 E
AREA EA 43.9
.95 VISIBILITY TO NE
TE FENCE
SEWER
44 ENTRY CONNECTION
179°58'36"
TE
POINT
BFC ACCESS STAIRS MINIMAL DUE TO
3.138
LEISURE BED Timber treads on steel stringers
TE MESH
TIMBER GARDEN EDGE 1150 4850
.0 .94 1 for maintenance access
45 verge
RL 42940
Separating garden beds from public
44 6 .7
turf. Refer Typical Detail 04/LP05 44.7 44 + BOW 41.800 .8 1
43 TREE
WIRE
ELANDA
1 TILES
4. 9
Ht = 7
Telstra Pit
4 .67 GARAGE H2 BALCONY + TOW 42.750 Spread = 7.0
44 + RL 42.750 Trunk = 0.30
359°59'36"
RL 42940
UP
.40 Type = PALM
BED 43
BATH SYN
9"
29' 2
MASONRY WALL <1000 HIGH
.32
197°
1:6 1:8 LIFT
44 Select concrete block or 'Link'
M|
1:8
EA EA
3.593
block retaining wall system
.45
+ BOW 42.050
41 .75
RY 1
RL 43065
TE
44 LIFT TILES
NDA
+ TOW 42.750 1800 TIMBER SCREEN FENCE
BOU
RL 4 BATH
4255 BED To side and rear property boundaries
TY
and separating private courtyards
PER
.39
UP + RL 42.750
PRO
44 GARAGE .54
SYN 43 CP
PROPERTY BOUNDARY 16.098M | 359° 59' 36"
H1
RL 42940 2210
44.5
TE
.37 TREE
COMMON GARDEN AREAS
4.2
0 RL 42940 44 Ht = 7
Mulched garden beds with tiered planting .39 4 .82 Spread = 7.0
BUP4358
44 41
TE
Trunk = 0.30
29"
arrangement. Refer Planting Plan LP02 LEISURE BED
6 BFC Type = PALM
for detailed planting design and schedule 4 .1 .41
4 .1 6 44
29'
ENTRY
44 RL 43940
°
UP ENTRY PATH
TREE
197
PRIVATE ENTRY PATHS + BOW 42.500
333
Ht = 7
Select combination of tiled and exposed EA RL 42940
Spread = 7.0
TE
7000L TANK
.26 34
42 42..97
aggregate surfaces as indicated Trunk = 0.30
.83 Type = PALM
0
43 .5 41
.
42.5
269°56'38"
PROPERTY BOUNDARY 29.463M | 269° 56' 38"
TIMBER PAILING FENCE
LINE
2 0 3 7m
42
.15
1129
43
Top 47.85
Bot 46.37
44
Window
SEWER
.90
43 R48.57 R48.23
SCALE 1:150
EDGE OF BITUMEN
LEGEND 0 .85
44. 43
BROOM FINISHED SELECT EXPOSED OUTDOOR TILES SELECT 40MM SELECT 70-150MM TYPICAL MULCHED TYPICAL MASONRY WALL 1.8M HIGH TIMBER TIMBER EXISTING TREES
CONCRETE AGGREGATE SURFACE REFER ARCHITECT SYNTHETIC TURF DECORATIVE PEBBLE GARDEN BED TURF LESS THAN 1M HIGH SCREEN FENCE
TE GARDEN EDGE TO BE PROTECTED
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 1 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP01 B
scale: 1:150 @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP GROUND FLOOR LANDSCAPE PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 1 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT Section 3
2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 4
.5
45
(7) HIB Yel PP (1) CUP ana (22) LIR EG (2) PTY ele (4) COR hyb (1) COR hyb (5) LIR EG
(5) CLI min (2) CLI min
43.0
42.5
.0
(5) VIO ban (3) VIO ban (6) ACM smi
45
89°56'36"
43.5
(1) ELA eum
5
RL 43140 RL 43140
41.
(1) ACR imp
179°58'36"
(2) RAN fit
(24) PHI XD (7) FIC GI
(1) PTY ele RL 43140
(8) VIO ban
(4) BAN rob
(6) CAR DS
(1) PAN tec (8) ALP zer
359°59'36"
RL 43330 UP (10) DOO asp
(5) NEO BN
(10) VIO ban
.5
(4) COR hyb
45
(6) COR hyb
(3) ACM smi
(4) ROS pro (1) ELA eum RL 43455
(1) ACR imp
STREET
1:6 1:8 UP
1:8
(15) LIR EG (7) ALP zer
RL 43330
RL 4
4 773 (4) BAN rob
(10) DOO asp
(5) NEO BN
RL 43140 (10) VIO ban
S
RL 44540 RL 42940 (1) PET tri
(4) CAR DS
179°58'36" (2) ACM smi
(30) PHI XD (10) DOO asp 3.138
(5) NEO BN
.0
45
RL 42940 (10) VIO ban (1) ACR imp
(1) PHE woo
Telstra Pit (1) PTY ele
ELANDA
359°59'36"
RL 42940
UP
(1) PAN tec
(1) ELA PD
(4) ROS pro (1) ELA eum (4) COR hyb
1:6 1:8 (8) ALP zer
1:8
RL 43065 (1) RAN fit (1) ELA PD
(24) PHIRXD (1) PAN tec (6) NEO BN
L 44
255
(3) BAN rob
UP (6) ALP zer
(1) PTY ele
RL 42940 (8) ACM smi
5 pro
4.ROS
4(1)
(7) FIC GI RL 42940
(3) CAR DS (8) VIO ban (4) COR hyb
(5) COR hyb
29"
(9) BLE SL
(6) VIO ban
29'
(1) ACR imp
RL 43940
°
UP (10) DOO asp
197
(5) NEO BN
RL 42940
(1) ELA eum (10) VIO ban
0
.5
.
42.5
269°56'38"
42
43
(7) HIB Yel (1) CUP ana (20) LIR EG (2) PTY ele (2) ELA PD
2 0 3 7m
LEGEND 0
44.
PLANTING TURF SUNTHETIC CANOPY COLUMNAR FEATURE GROUND
SHRUBS
AREAS EXTENTS TURF TREES TREES SHRUBS COVERS SCALE 1:150
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 2 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP02 B
scale: 1:150 @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP GROUND FLOOR PLANTING PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 2 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 5
PROPERTY BOUNDARY 33.544M | 89° 56' 36"
SOLID BALUSTRADE
SPIRAL STAIRS
SYN RL 52320
PROPERTY BOUNDARY 15.091M | 359° 59' 36"
BALUSTRADE
ROOFTOP
PLANTER
TERRACE
(5) CRA ova POOL
POOL
(6) SEN BC TILES
PRIVATE TOOFTOP TERRACE
VERTICAL BATTEN BALUSTRADE LIFT Tiled finish to Architect's Detail.
GATE
POOL
BBQ AREA
PROPERTY BOUNDARY 15.091M | 179° 58' 36"
SLAB EDGE
BBQ AREA
GATE
POOL
LIFT
CONTAINERIZED PLANTER
Maximum 1.2m high 150 Series blockwork requiring ROOFTOP
POOL TERRACE
waterproofing, irrigation and drainage connected to POOL
BALUSTRADE
stormwater system. Refer typical detail
(3) CRA ova TILES
(5) SEN BC
SYN
(10) HIB Red RL 52320
(11) ROS pro
(10) HIB Red
(11) ROS pro
RL 52120
SYN
(3) CRA ova PLANTER
TILES
BALUSTRADE
(5) SEN BC
POOL
POOL
SELECT SYNTHETIC TURF ROOFTOP
TERRACE
Installed over podium slab to manufacturer's
9"
29' 2
specification. Ensure falls towards podium LIFT
197°
drainage inlets to eliminate ponding.
GATE
POOL
BBQ AREA
M|
3.593
BBQ AREA
GATE
POOL
RY 1
NDA
LIFT
BOU
TY
ROOFTOP
PER
DE
POOL TERRACE
STRA
PRO
(5) CRA ova POOL
BALU
PROPERTY BOUNDARY 16.098M | 359° 59' 36"
PLANTER
(6) SEN BC
TILES
S
GLAS
SYN RL 52120
SOLID BALUSTRADE
PROPERTY BOUNDARY 29.463M | 269° 56' 38"
2 0 3 7m
LEGEND
CONTAINERIZED MASONRY WALL MAX TILED FINISH SYNTHETIC GROUND
SHRUBS
PLANTERS THAN 1.2M HIGH REFER ARCHITECT TURF COVERS SCALE 1:150
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 3 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP03 B
scale: 1:150 @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP ROOFTOP LANDSCAPE PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 3 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 6
NOTES:
100
TURF: GREEN COUCH OR WINTERGREEN MULCH: AS SPECIFIED 1. ALL TIMBER TO BE ACQ TREATED ROUGH SAWN APPEARANCE GRADE HWD OF
COUCH UNLESS OTHERWISE SPECIFIED. A SINGLE SPECIES.
ROLLED AND WATERED-IN AT PLANTING. 2. ALL TIMBER IN CONTACT WITH GROUND TO BE PRESERVATIVE TREATED TO
300
REFER SPECIFICATION NOTES TOPSOIL: SITE SOIL, IMPROVED SITE SOIL PLANT: AS SPECIFIED ON PLANS UNLESS HAZARD CLASS H5 TO AS 1604 & HAVE A DURABILITY CLASS 1 OR 2 TO AS 5604.
OR IMPORTED SOILMIX AS SPECIFIED DIRECTED AND APPROVED BY PROJECT 3. ALL TIMBER TO BE FREE OF KNOTS, CRACKS OR ANY MAJOR DEFECT.
100
TOPSOIL: SITE SOIL, IMPROVED SITE SOIL LANDSCAPE ARCHITECT 4. TO FORM CURVES SAW CUT RELIEF TO EDGE TO PROMOTE EASE OF BENDING.
OR IMPORTED SOILMIX AS SPECIFIED STAKE AT CLOSER INTERVALS WHERE REQUIRED.
150
MAINTAIN MINIMUM 50mm SEPARATION
200
CULTIVATED SUBGRADE: RIP / CULTIVATE CULTIVATED SUBGRADE: RIP / CULTIVATE MULCH: AS 100X25mm TIMBER EDGE
BETWEEN MULCH AND STEM OF PLANT TO
EXISTING SUBGRADE AS SPECIFIED EXISTING SUBGRADE AS SPECIFIED SPECIFIED FIXED WITH 2 (MIN.)
ENSURE ADEQUATE AIR CIRCULATION
EXISTING SUBGRADE GARDEN PROFILE: GALVANISED NAILS PER
EXISTING SUBGRADE SLOW RELEASE FERILISER: AS SPECIFIED REFER TO DETAIL STAKE.
& SPECIFICATION FLUSH
25
NOTES: NOTES: TURF PROFILE: REFER
DETAIL & SPECIFICATION
Y
1. ENSURE PRIOR TO LAYING OF TURF THAT ALL FALLS ACROSS SLOPES HAVE 1. ALL UNDERGROUND SERVICES SHALL BE LOCATED AND CLEARLY MARKED
2Y
EVEN GRADE FALLS WITH NO BUMPS OR HOLLOWS. PRIOR TO GARDEN PREPARATION . ENSURE CAUTION WHEN CULTIVATING OVER
X TOPSOIL: AS SPECIFIED
2. ALL TURF SHALL BE LAID IN A STRETCHER BOND PATTERN (PARALLEL TO SERVICE LINES, PIPES AND AROUND EXISTING TREE ROOTS AND IF NECESSARY
CONTOURS ON SLOPES) AND EACH TURF SEGMENT FIRMLY CLOSE BUTTED. CULTIVATE USING HAND TOOLS. DO NOT CULTIVATE WITHIN 600mm OF PLANTING HOLE: OVER EXCAVATE HOLE BY
TURF SEGMENTS SHALL NOT BE STRETCHED TO FIT. PROPOSED OR EXISTING HARD PAVED AREAS OR STRUCTURES. TWICE THE WIDTH (2X) AND DEPTH (2Y) OF CULTIVATED SUBGRADE:
3. TURF TO BE LIGHTLY WATERED DURING THE INSTALLATION PROCESS AND BE 2. PROFILE THE EXISTING SUBGRADE TO ACHIEVE THE DESIRED F.S.L AND THE POT SIZE. CULTIVATE BASE OF HOLE AS SPECIFIED
MAINTAINED IN A MOIST CONDITION THROUGHOUT THE INSTALLATION PROCESS. DRAINAGE FALLS PRIOR TO APPLICATION OF TOPSOIL AT SPECIFIED DEPTH CULTIVATED SUBGRADE: RIP / CULTIVATE 350X50X50mm STAKES AT
4. ALL TURF SHALL FINISH FLUSH, AFTER TAMPING WITH ADJACENT FINISHED 3. WHERE EXISTING SITE TOPSOIL IS BEING REINSTATED A PRE-EMERGENT EXISTING SUBGRADE AS SPECIFIED 1000mm (MAX.) CENTRES.
SURFACE LEVELS AND BE EVENLY GRATED BETWEEN TURF SEGMENTS WITH NO HERBICIDE SHALL BE APPLIED DURING TOPSOIL INSTALLATION (ACCORDING TO EXISTING SUBGRADE
EXISTING SUBGRADE
VARIATION GREATER THAN +/- 10mm. MANUFACTURER'S SPECIFICATION)
5. TURF SHALL BE LIGHTLY ROLLED WITHIN 24 HRS OF INSTALLATION. 4. FINISH THE SURFACE LEVEL OF SOIL TO ALLOW 100mm DEPTH OF ORGANIC 2X 200 200
MULCH ENSURING MULCH F.S.L IN 25mm BELOW F.S.L OF ADJOINING SURFACES
01 TYPICAL TURF PROFILE 02 TYPICAL PLANTING AREA PROFILE 03 TYPICAL PLANTING DETAIL 04 TYPICAL TIMBER GARDEN EDGE
LP04 SCALE 1:20 LP04 SCALE 1:20 LP04 SCALE 1:20 LP04 SCALE 1:20
BASIN: FORM AN EARTHEN BASIN AROUND
THE BASE OF THE PLANT TO HOLD WATER
NOTES
DRIP IRRIGATION: CONNECTED TO MULCH: FINISH MULCH LEVEL TO BE 25mm BELOW
TREE: AS SPECIFIED ON PLANS UNLESS 1. CHECK ALL STOCK ONCE REMOVED
NON-TOWN WATER SUPPLY TOP OF PLANTER. REFER SPECIFICATION NOTES
DIRECTED AND APPROVED BY PROJECT FROM POT TO ENSURE STOCK IS NOT
LANDSCAPE ARCHITECT ROOT BOUND. IF ROOTS ARE BOUND, UNDERSTOREY PLANTING: REFER PLANTER: BLOCK WALL. REFER
REJECT. PLANTING PALETTE STRUCTURAL ENGINEERS DETAIL
25
STAKES: 2 NO. HWD STAKES 1800X38X38mm 2. PLANTS TO BE HEALTHY AND
DRIVEN 600mm INTO GROUND. DO NOT VIGOROUS, TREES MUST HAVE A FERTILIZER: REFER
INTERNAL DEPTHS (MIN) FOR:
PENETRATE ROOTBALL. SINGLE TERMINAL SHOOT (UNLESS SPECIFICATION NOTES
200
GROUNDCOVERS 600mm
LARGE SHRUBS 800mm
100
SPECIES IS MULTI-STEMED) REFER WATERPROOF MEMBRANE:
SMALL SHRUBS AND
TIES: PROVIDE NON-ABRAISIVE,
TREES: 1200mm
SPECIFICATION. ENSURE NO INSECT REFER MANUFACTURER
NON-CUTTING MATERIAL TIES IN A FIGURE 8
DAMAGE.
PATTERN FIXED SECURELY TO STAKES PODIUM SOIL BLEND: REFER
3. STAKING OF TREES SHALL BE
MAINTAIN MINIMUM 50mm SEPARATION UNDERTAKEN AT THE TIME OF SPECIFICATION NOTES
MULCH: AS
BETWEEN MULCH AND STEM OF PLANT TO PLANTING. PLACE ONE STAKE ON THE
SPECIFIED ADJACENT SURFACES: REFER
ENSURE ADEQUATE AIR CIRCULATION WINDWARD SIDE OF THE TREE. PLANS AND SPECIFICATION
400
50
4. STAKES TO BE HARDWOOD, FREE
SLOW RELEASE FERILISER: AS SPECIFIED FROM KNOTS OR TWISTS AND
POINTED AT ONE END.
40
TOPSOIL: SITE SOIL, IMPROVED SITE SOIL OR
5. REMOVE ALL NURSERY STAKES AND
IMPORTED SOILMIX AS SPECIFIED. FORM
Y
BAMBOO STAKES FROM ALL TREES AT
SHALLOW DEPRESSION AROUND TOP OF
2Y
THE TIME OF PLANTING. PODIUM SLAB SAND: MINIMUM 50mm DEPTH
ROOTBALL TO IMPROVE WATER RETENTION
6. THOROUGHLY WATER THE TREES OF COARSE WASHED SAND.
PLANTING HOLE: OVER EXCAVATE HOLE BY X BEFORE PLANTING, IMMEDIATELY GEOTEXTILE: BIDUM FILTER LAYERS
TWICE THE WIDTH (2X) AND DEPTH (2Y) OF AFTER PLANTING AND AS REQUIRED INSTALLED TO MANUFACTURERS SPEC DRAINAGE CELL: VERSICELL DRAINAGE
THE POT SIZE. CULTIVATE SIDES AND BASE TO MAINTAIN GROWTH RATES FREE OF DRAINAGE: CONNECTION TO STORMWATER MODULES OR EQUIVALENT. INSTALL TO
OF HOLE EXISTING SUBGRADE STRESS THROUGHOUT THE PLANTING SYSTEM. REFER STRUCTURAL AND MANUFACTURER'S SPEC
ESTABLISHMENT PERIOD. HYDRAULIC ENGINEER'S DETAIL
2X WATERPROOF MEMBRANE:
REFER SPECIFICATION
05 TYPICAL ADVANCED TREE 06 TYPICAL CONTAINERIZED PLANTER DETAIL - ROOFTOP LEVEL
LP04 SCALE 1:40 LP04 SCALE 1:40
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 4 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP04 B
scale: AS SHOWN @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP TYPICAL LANDSCAPE DETAILS project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 4 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 7
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 5 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP05 B
scale:
- Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP PLANTING SCHEDULES project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 5 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT 2021
© Openspace Architecture 2021 abn 91 651 947 240