Original source · versioned page text
Landscape
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
NOTES:
100
TURF: GREEN COUCH OR WINTERGREEN MULCH: AS SPECIFIED 1. ALL TIMBER TO BE ACQ TREATED ROUGH SAWN APPEARANCE GRADE HWD OF
COUCH UNLESS OTHERWISE SPECIFIED. A SINGLE SPECIES.
ROLLED AND WATERED-IN AT PLANTING. 2. ALL TIMBER IN CONTACT WITH GROUND TO BE PRESERVATIVE TREATED TO
300
REFER SPECIFICATION NOTES TOPSOIL: SITE SOIL, IMPROVED SITE SOIL PLANT: AS SPECIFIED ON PLANS UNLESS HAZARD CLASS H5 TO AS 1604 & HAVE A DURABILITY CLASS 1 OR 2 TO AS 5604.
OR IMPORTED SOILMIX AS SPECIFIED DIRECTED AND APPROVED BY PROJECT 3. ALL TIMBER TO BE FREE OF KNOTS, CRACKS OR ANY MAJOR DEFECT.
100
TOPSOIL: SITE SOIL, IMPROVED SITE SOIL LANDSCAPE ARCHITECT 4. TO FORM CURVES SAW CUT RELIEF TO EDGE TO PROMOTE EASE OF BENDING.
OR IMPORTED SOILMIX AS SPECIFIED STAKE AT CLOSER INTERVALS WHERE REQUIRED.
150
MAINTAIN MINIMUM 50mm SEPARATION
200
CULTIVATED SUBGRADE: RIP / CULTIVATE CULTIVATED SUBGRADE: RIP / CULTIVATE MULCH: AS 100X25mm TIMBER EDGE
BETWEEN MULCH AND STEM OF PLANT TO
EXISTING SUBGRADE AS SPECIFIED EXISTING SUBGRADE AS SPECIFIED SPECIFIED FIXED WITH 2 (MIN.)
ENSURE ADEQUATE AIR CIRCULATION
EXISTING SUBGRADE GARDEN PROFILE: GALVANISED NAILS PER
EXISTING SUBGRADE SLOW RELEASE FERILISER: AS SPECIFIED REFER TO DETAIL STAKE.
& SPECIFICATION FLUSH
25
NOTES: NOTES: TURF PROFILE: REFER
DETAIL & SPECIFICATION
Y
1. ENSURE PRIOR TO LAYING OF TURF THAT ALL FALLS ACROSS SLOPES HAVE 1. ALL UNDERGROUND SERVICES SHALL BE LOCATED AND CLEARLY MARKED
2Y
EVEN GRADE FALLS WITH NO BUMPS OR HOLLOWS. PRIOR TO GARDEN PREPARATION . ENSURE CAUTION WHEN CULTIVATING OVER
X TOPSOIL: AS SPECIFIED
2. ALL TURF SHALL BE LAID IN A STRETCHER BOND PATTERN (PARALLEL TO SERVICE LINES, PIPES AND AROUND EXISTING TREE ROOTS AND IF NECESSARY
CONTOURS ON SLOPES) AND EACH TURF SEGMENT FIRMLY CLOSE BUTTED. CULTIVATE USING HAND TOOLS. DO NOT CULTIVATE WITHIN 600mm OF PLANTING HOLE: OVER EXCAVATE HOLE BY
TURF SEGMENTS SHALL NOT BE STRETCHED TO FIT. PROPOSED OR EXISTING HARD PAVED AREAS OR STRUCTURES. TWICE THE WIDTH (2X) AND DEPTH (2Y) OF CULTIVATED SUBGRADE:
3. TURF TO BE LIGHTLY WATERED DURING THE INSTALLATION PROCESS AND BE 2. PROFILE THE EXISTING SUBGRADE TO ACHIEVE THE DESIRED F.S.L AND THE POT SIZE. CULTIVATE BASE OF HOLE AS SPECIFIED
MAINTAINED IN A MOIST CONDITION THROUGHOUT THE INSTALLATION PROCESS. DRAINAGE FALLS PRIOR TO APPLICATION OF TOPSOIL AT SPECIFIED DEPTH CULTIVATED SUBGRADE: RIP / CULTIVATE 350X50X50mm STAKES AT
4. ALL TURF SHALL FINISH FLUSH, AFTER TAMPING WITH ADJACENT FINISHED 3. WHERE EXISTING SITE TOPSOIL IS BEING REINSTATED A PRE-EMERGENT EXISTING SUBGRADE AS SPECIFIED 1000mm (MAX.) CENTRES.
SURFACE LEVELS AND BE EVENLY GRATED BETWEEN TURF SEGMENTS WITH NO HERBICIDE SHALL BE APPLIED DURING TOPSOIL INSTALLATION (ACCORDING TO EXISTING SUBGRADE
EXISTING SUBGRADE
VARIATION GREATER THAN +/- 10mm. MANUFACTURER'S SPECIFICATION)
5. TURF SHALL BE LIGHTLY ROLLED WITHIN 24 HRS OF INSTALLATION. 4. FINISH THE SURFACE LEVEL OF SOIL TO ALLOW 100mm DEPTH OF ORGANIC 2X 200 200
MULCH ENSURING MULCH F.S.L IN 25mm BELOW F.S.L OF ADJOINING SURFACES
01 TYPICAL TURF PROFILE 02 TYPICAL PLANTING AREA PROFILE 03 TYPICAL PLANTING DETAIL 04 TYPICAL TIMBER GARDEN EDGE
LP04 SCALE 1:20 LP04 SCALE 1:20 LP04 SCALE 1:20 LP04 SCALE 1:20
BASIN: FORM AN EARTHEN BASIN AROUND
THE BASE OF THE PLANT TO HOLD WATER
NOTES
DRIP IRRIGATION: CONNECTED TO MULCH: FINISH MULCH LEVEL TO BE 25mm BELOW
TREE: AS SPECIFIED ON PLANS UNLESS 1. CHECK ALL STOCK ONCE REMOVED
NON-TOWN WATER SUPPLY TOP OF PLANTER. REFER SPECIFICATION NOTES
DIRECTED AND APPROVED BY PROJECT FROM POT TO ENSURE STOCK IS NOT
LANDSCAPE ARCHITECT ROOT BOUND. IF ROOTS ARE BOUND, UNDERSTOREY PLANTING: REFER PLANTER: BLOCK WALL. REFER
REJECT. PLANTING PALETTE STRUCTURAL ENGINEERS DETAIL
25
STAKES: 2 NO. HWD STAKES 1800X38X38mm 2. PLANTS TO BE HEALTHY AND
DRIVEN 600mm INTO GROUND. DO NOT VIGOROUS, TREES MUST HAVE A FERTILIZER: REFER
INTERNAL DEPTHS (MIN) FOR:
PENETRATE ROOTBALL. SINGLE TERMINAL SHOOT (UNLESS SPECIFICATION NOTES
200
GROUNDCOVERS 600mm
LARGE SHRUBS 800mm
100
SPECIES IS MULTI-STEMED) REFER WATERPROOF MEMBRANE:
SMALL SHRUBS AND
TIES: PROVIDE NON-ABRAISIVE,
TREES: 1200mm
SPECIFICATION. ENSURE NO INSECT REFER MANUFACTURER
NON-CUTTING MATERIAL TIES IN A FIGURE 8
DAMAGE.
PATTERN FIXED SECURELY TO STAKES PODIUM SOIL BLEND: REFER
3. STAKING OF TREES SHALL BE
MAINTAIN MINIMUM 50mm SEPARATION UNDERTAKEN AT THE TIME OF SPECIFICATION NOTES
MULCH: AS
BETWEEN MULCH AND STEM OF PLANT TO PLANTING. PLACE ONE STAKE ON THE
SPECIFIED ADJACENT SURFACES: REFER
ENSURE ADEQUATE AIR CIRCULATION WINDWARD SIDE OF THE TREE. PLANS AND SPECIFICATION
400
50
4. STAKES TO BE HARDWOOD, FREE
SLOW RELEASE FERILISER: AS SPECIFIED FROM KNOTS OR TWISTS AND
POINTED AT ONE END.
40
TOPSOIL: SITE SOIL, IMPROVED SITE SOIL OR
5. REMOVE ALL NURSERY STAKES AND
IMPORTED SOILMIX AS SPECIFIED. FORM
Y
BAMBOO STAKES FROM ALL TREES AT
SHALLOW DEPRESSION AROUND TOP OF
2Y
THE TIME OF PLANTING. PODIUM SLAB SAND: MINIMUM 50mm DEPTH
ROOTBALL TO IMPROVE WATER RETENTION
6. THOROUGHLY WATER THE TREES OF COARSE WASHED SAND.
PLANTING HOLE: OVER EXCAVATE HOLE BY X BEFORE PLANTING, IMMEDIATELY GEOTEXTILE: BIDUM FILTER LAYERS
TWICE THE WIDTH (2X) AND DEPTH (2Y) OF AFTER PLANTING AND AS REQUIRED INSTALLED TO MANUFACTURERS SPEC DRAINAGE CELL: VERSICELL DRAINAGE
THE POT SIZE. CULTIVATE SIDES AND BASE TO MAINTAIN GROWTH RATES FREE OF DRAINAGE: CONNECTION TO STORMWATER MODULES OR EQUIVALENT. INSTALL TO
OF HOLE EXISTING SUBGRADE STRESS THROUGHOUT THE PLANTING SYSTEM. REFER STRUCTURAL AND MANUFACTURER'S SPEC
ESTABLISHMENT PERIOD. HYDRAULIC ENGINEER'S DETAIL
2X WATERPROOF MEMBRANE:
REFER SPECIFICATION
05 TYPICAL ADVANCED TREE 06 TYPICAL CONTAINERIZED PLANTER DETAIL - ROOFTOP LEVEL
LP04 SCALE 1:40 LP04 SCALE 1:40
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 4 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP04 B
scale: AS SHOWN @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP TYPICAL LANDSCAPE DETAILS project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 4 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: OCT 2021
© Openspace Architecture 2021 abn 91 651 947 240