www.ac   ss.gs                                                                                       +GILtEHI
                                                                                                 SUT1-ERI.AN)



Zinc (Zn):                                              4.3.2      Groundwater Quality

Topsoil Zn levels ranged from <0.1 to 0.7ppm; the       Throughout the monitoring period, the results for
majority of these samples were within the               mean pH ranged from 5.09 to 9.15.

acceptable range. With the exception of GQAL2,
                                                        Results for electrical conductivity (EC)ranged
subsoil Zn levels were between <0.1 and 0.1 ppm.
                                                        from 0.06I1S/cm at BH58 on 27 March 2012 to

                                                        0.64I1S/cm at both GW2 and GW5 on 13 April
Manganese (Mn):
                                                        2012. Mean results were indicative of a freshwater
All Mn levels for the topsoil and subsoil samples
                                                        environment, and were below 0.62I1S/cm across
recovered from the site were low (<2ppm).These
                                                        the bore network.
levels indicate that soil Mn may need

supplementation with fertiliser.                        The concentrations of dissolved metals were

                                                        generally consistent across the bore network, with
Aluminium (AI):                                         limited variation between bores.

Topsoil AI levels ranged from 0.30 to
                                                        The largest range in dissolved metal
1.09meq/1 OOg; the majority of levels were
                                                        concentration was recorded for iron, which ranged
<1.00meq/1 OOg. Subsoil levels ranged from 0.33
                                                        from <0.05mg/L at BH28 to 5.19mg/L at GW2.
to 8.48meq/1 OOg. At pHw less than 5.0 these AI
                                                        The average concentration was 1 .36mg/L across
concentrations may be a limitation to deep rooting
                                                        the bore network. For short-term irrigation, the
crops, due to AI toxicity.
                                                        iron concentration will not be a limiting factor for

                                                        agricultural production. However, iron
Iron (Fe):
                                                        concentrations will pose issues if long-term
Topsoil Fe levels ranged from 16 to 116ppm,
                                                        irrigation practices and/or if trickle or dripper
subsoil levels ranging from 4 to 56ppm. The
                                                        systems are implemented. Iron concentrations
majority of Fe levels were above 30ppm in the
                                                        above 2.0mg/L used for long-term irrigation may
topsoils and below 30ppm in the subsoils. Fe
                                                        lead to clogging of irrigation systems (trickle or
toxicity is rarely a limiting factor for agricultural
                                                        drippers) and can also cause plant foliage
production.
                                                        damage and blemishes 11. If trickle or drippers are
                                                        not used and the crop is not sprayed directly, then
4.3     Groundwater
                                                        higher concentrations of iron is acceptable.
4.3.1    Groundwater Level                              The ionic balance of the water sampled from the
Groundwater was encountered at varying depths
                                                        majority of bores across the Lake Weyba
from 1.85-12.85m below relative level (RL)across
                                                        development site was satisfactory (i.e less than
the site during the site investigations.                5%12).

Generally, the highest levels have been recorded        The majority of bores in the Lake Weyba

following periods of heavy rain. For example, the       development area are very similar in their
majority of bores were at their highest level during    proportions of cations and anions. BH45, BH4,
sampling in early June, following a rain event of       GW4 and BH23 appear slightly different to the ion

85mm.                                                   mix of the other bores. These bores are located in

                                                        wetland areas, which would influence the ionic
For a significant portion of the site, the clayey low
                                                        11
permeability subsoils, presence of gley, grey and            ANZECC/ARMCANZ, 2000. Australian and New Zealand
mottles at depth suggest the soil profile does have     Guidelines for Fresh and Marine Water Quality, Volume 3:
                                                        Primary Industries   _
                                                                                 Rationale and Background Information
a permanent or periodical shallow water table.
                                                        \Chapter 9). Australian Water Association, Australia.
                                                         2
This indicates that drainage and the shallow depth         Steel, A. and Whitfield, C.P. (1996)’Chapter 14 Use and
                                                                                                            _




of the watertable are potentially limiting to plant     Reporting of Monitoring Data’ in Water Quality Monitoring A_




                                                        Practical Guide to the Design and Implementation of
production on this site.                                Freshwater Quality Studies and Monitoring Programmes. Eds.
                                                        Jamie Bartram and Richard Balance. UNEP/WHO: United
                                                        Kingdom.




1 0838_AlA_RAK1 F.DOCXI NORTHBROOK CORP P/L / GQAl & SCl REPORT, NOOSA ON WEYBA, QUEENSLAND                             25

Used in these records

About this file

File size
126 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 19 of 37 Appendix 17 - GQAL and SCL Assessment MCU12_0208.pdf · 126 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.