Original source · versioned page text
2020-07-16 SM Agenda - Item 1 - Attachment 5 - Final Noosa Plan 2020 Part 8-10 Schedules & Appendix
The original of this document is very large (19.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Performance outcomes Acceptable outcomes
PO7 AO7
Lot design and building siting minimises bushfire hazard risk to Each residential lot:
people and property. (a) includes a building envelope, identified on a plan of
subdivision;
(b) is of sufficient size and shape to allow for efficient
emergency access to buildings for fire fighting appliances
(e.g. by avoiding battleaxe/hatchet lots and long narrow lots
with long access driveways to buildings);
(c) where more than 2500m², achieves setbacks from
hazardous vegetation in line with Bushfire Attack Level 29
requirements as per AS3959; and
(d) is designed so that buildings and structures are sited in
locations of lowest hazard within the lot and elements of the
development least susceptible to fire are closest to the fire
hazard.
Firebreaks and fire access tracks
PO8 AO8.1
Firebreaks and fire access tracks provide: Where development involves the creation of a new road and
(a) adequate access for fire fighting and other emergency lots, a firebreak is provided by providing a cleared road reserve
vehicles; and not less than 20 metres wide and maximum gradient of 12.5%
(b) adequate access for the evacuation of residents and around the perimeter of the subdivision, between the created
emergency personnel in an emergency situation. lots and surrounding vegetated lands.
OR
AO8.2
Fire access tracks are provided between the created lots and
surrounding vegetated land that:
(a) have a cleared minimum width of 6 metres;
(b) have a maximum gradient of 12.5%;
(c) provide unbroken access for fire fighting vehicles;
(d) provide passing bays and turning areas;
(e) are located within an access easement that is granted in
favour of Noosa Council and the Queensland Fire and
Rescue Service.
AO8.3
Bushfire management measures are carried out on the subject
property and not any adjoining property.
8.2.4 Coastal Protection and Scenic Amenity Overlay Code
8.2.4.1 Application
(1) This code applies to assessable development:
(a) subject to the Coastal Protection and Scenic Amenity Overlay shown on the overlay maps contained within Schedule 2
(Mapping); and
(b) identified as requiring assessment against the Coastal Protection and Scenic Amenity overlay code by the tables of
assessment in Part 5 (Tables of assessment).
(2) All provisions in this code are assessment benchmarks for applicable assessable development.
NOOSA PLAN 2020 Page 12 of 44