Log in to see the plans as drawn Performance Outcomes Acceptable Outcomes
Bushfire Hazard Overlay Map in Schedule 2 and not in a water supply, the premises has:
service area, an adequate, reliable, safely located and freely (a) an accessible dam, swimming pool or water tank available
accessible water supply is provided for fire fighting purposes, for firefighting purposes with an onsite water volume of not
which is in addition to day to day water supply. less than 5,000 litres; and
(b) a water supply outlet pipe 50 millimetres in diameter and
fitted with a standard fire brigade fitting connected to the
water supply (other than where the water supply is in a
swimming pool or dam).
Editor’s Note — Water supply capacity for firefighting purposes is
in addition to water supply capacity for household use.
Flood Hazard Area
PO15 AO15.1
Where located in the Flood Hazard Area as shown on Flood The finished floor level of habitable rooms is at least 300
Hazard Overlay Map in Schedule 2 the development is designed millimetres above the Defined flood event (DFE).
and sited to ensure risk to people and property from flooding is
avoided or minimised. OR
AO15.2
Where the DFE has not been modelled for the area, the finished
floor level of habitable rooms is at least 500 millimetres above the
highest recorded flood.
Editor's note—The QDC mandatory provisions MP3.5 also apply
to the construction of buildings in flood hazard areas.
Landslide Hazard Area
PO16 AO16.1
Development maintains the safety of people, property and Development, including associated access, is not located on land
hazardous materials stored in bulk from the risk of landslide. identified as a landslide hazard area on a Landslide Hazard
Overlay Map.
AO16.2
Development, including associated access, is located outside
moderate, high and very high landslide hazard areas and areas
with 15% slope or greater, as determined by a sitespecific slope
analysis.
Editor's Note—A site specific geotechnical assessment may be
used to demonstrate that although the proposed development is
shown on the Landslide Hazard Overlay as being in the moderate,
high or very high landslide hazard area, the landslide risk is low or
very low
AO16.3
A sitespecific geotechnical assessment is prepared by a
registered professional engineer to certify that:
(a) the stability of the site, including associated buildings and
infrastructure, will be maintained and operational for the life
of the development;
(b) the site is not subject to the risk of landslide activity
originating from other land, including land above the site;
and
(c) development of the site will not increase the risk of
landslide activity on other land.
Editor's Note— PSP8 Natural Hazards provides further guidance
NOOSA PLAN 2020 Page 37 of 150