Original source · versioned page text
Building plans V2
Original PDF page 2, section 2. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn27
27.25
26.8 .0
RL 26.82
- ALL BUILDING MATERIALS OR WASTE ON SITE IS TO BE FULLY REMOVED.
27.11
DEMOLITION.
27
26.57 26.63
- ANY DEPRESSIONS TO NATURAL GROUND LEVEL WILL REQUIRE TO BE ADEQUATELY FILLED. EMT/PIER 26.72
26.86 RL 26.800
26.85
16
25.62
27.41
6
Sleeper Retaining
Gate
Timber Fence on
Existing
FILL 0.500
Lowset
- ANY EXCESS FILL IS REMOVED WHICH MAY IMPACT ON CONSTRUCTION SITE ACCESS.
House
SOLAR INVERTER
.4
Maheno Court
25.64278°53'10"
Existing Timber
25 .4
PROPOSED 27
Garden
23.0 25
UTILITIES / SERVICES: I.E.
T L '10"
27.55
15
3-PHASE SOLAR METER BOX
7
22.894
.6
.6
- GAS METER AND ASSOCIATED PIPE WORK ARE REMOVED BACK TO SITE BOUNDARY.
26.88
Existing Timber Sleeper Retaining Wall
RESIDENCE 27
E M 98°53
LOCATION OF SOLAR PANELS
- ELECTRICAL METER AND ASSOCIATED SERVICES ARE REMOVED TO AGREED SAFE DISTANCE
5,547
26.86
(BOUNDARY/POLE). 8
7.
27.55
FFL 27.610 PAD RL WALL RL 26.800 2
Wall
26.6
- WATER METER REMAINS CONNECTED AND ASSOCIATED PIPE WORK ARE REMOVED BACK TO APPROX. LOCATION OF 2000mm H
8
Patio
THE WATER METER.
27.300 .0
ENGINEERED RETAINING WALL BY
25.94
.8
26.55
FILL 0.500
28
26
OWNER PRIOR TO EARTHWORKS
25
98°58'20"
- TELEPHONE & DATA CABLES ARE REMOVED BACK TO SITE BOUNDARY. EXISTING PATIO SHOWN DASHED TO BE
.6
5,000
16.001
26
3
27.74
- OWNERS TO LOCATE, CUT AND CAP OFF THE EXISTING SEWER AND STORMWATER CONNECTION .2 REMOVED BY OWNER AS PART OF
.8
28
5
Vegetation
EXISTING RETAINING WALL
POINT TO PREVENT INCIDENCE OF BUILDING MATERIALS ENTERING THOSE SYSTEMS AND .0 OMP DEMOLITION.
Floor Level 26.16
26.54
TO BE REMOVED BY OWNER
26
26.85
8
LEAVING YOUR SITE. THESE WORKS ARE TO BE COMPLETED IN ACCORDANCE WITH AS 3500 AS PART OF DEMOLITION. 26.60
25.96 28.4
4,000
9
REGULATIONS AND ARE TO CLEAR THE PROPOSED DWELLING BY A MINIMUM OF 1.2M, OTHERWISE 26.8
28.49
27.74
Existing
APPROX. DRIVEWAY
26
Shed
Stormwater Pit
FURTHER CHARGES MAY APPLY.
RL 26.63
28.70
.7
RL 26.600 BY OWNER
5
Not Located
26.80
26.65 28.6
12
Conduit
PLEASE NOTE IF THIS CANNOT BE ACHIEVED THE OWNER WILL NEED TO APPLY TO THE LOCAL
26
51m² TOTAL
4,990 11
Drain
10
.7
FILL 0.700 EV CAR CHARGER
File Location: G:\Queensland\Drafting\Job Files\Job Files 500000\502900 files\502921 - Massey\Plans\502921 Massey_AC21.pln
9
AUTHORITIES FOR A NEW SEWER CONNECTION POINT, THESE WORKS WILL NEED TO BE (G-FRAM-EV001) (34m² TO BDY) 28.8
CUT/FILL CALCULATIONS
26
COMPLETED PRIOR TO COMMENCEMENT OF CONSTRUCTION. .8
WALL
26.8
.6
26
26.84
26.76
0
- OWNER TO PROVIDE THE BUILDER WITH A FINAL COUNCIL CAP AND SEAL INSPECTION
13
29.0 APPROX. IMPORT/EXPORT FILL
CERTIFICATE TO ALL SERVICES IN ADDITION TO FORM 4J- 751635 PAGE 9 OF 19 SIGN OFF. IF THIS 6,512
27.77
14
EXISTING EXISTING RETAINING WALL
26
Light Pole
26.8
#335302
7
IS NOT PROVIDED THEN FURTHER CHARGES MAY BE APPLIED BY VARIATION FOR ADDITIONAL RL 26.720
WALL
.8
GARAGE
2,680
Existing Timber Sleeper Retaining Wall SHOWN DASHED TO BE REMOVED BY CUT VOLUME 0.00m³
2
2,500
Meter x 2 3
OMP
29.2
No Mk
WORKS REQUIRED.
Found
27.79 OWNER AS PART OF DEMOLITION.
4
FILL 0.580 Thick Vegetation
29.35
29.14
29.28
- THE OWNER(S) ARE TO INSTALL A CONDUIT FROM THE CAPPED OFF SEWER POINT TO THE FILL VOLUME 143.78m³
9
3.002 (Inaccessible) (28.483)
Hyd
W
SURFACE AND THEN PROVIDE A PLAN SHOWING TWO 90 DEGREE MEASUREMENTS FROM
H
186°57'40" DIFFERENCE 143.78m³
No Mk
Found
29.49 W
No Mk
Found
BOUNDARIES PLUS A DEPTH. EXISTING RETAINING WALL
THIS SHOULD BE PROVIDED AT THE COMPLETION OF DEMOLITION PRIOR TO BRIGHTON HOMES AIR CONDITIONING UNIT RL 26.799 TO BE REMOVED BY CLIENT RL 26.808 29.4
29.38
29.52
FILL 0.501 AT TIME OF DEMOLITION, TO TONNAGE: 143.78m³ x 2.25 = 323.51t
Not Located
COMMENCING ON SITE. FILL 0.492
Sewer M/H
HOT WATER SERVICE BE BATTERED TO SUIT NEW 324 TONNES OF IMPORT FILL
ASBESTOS: STREET FRONTAGE
Highset House
- A SITE CLEARANCE CERTIFICATE AND FORM 4 (QLD SPECIFIC) ARE REQUIRED TO BE SUPPLIED
LPG MOUNTING BRACKET GULLY GRATE / SPOON DRAIN
Well Away
TO BRIGHTON HOMES BY THE OWNER(S) PRIOR TO BRIGHTON HOMES COMMENCING WORK ON EXISTING RETAINING WALL TO
AND CONCRETE PAD BY OWNER AFTER HANDOVER
Existing
BE REMOVED BY OWNER AS
YOUR (EXCHANGE BOTTLES ONLY)
SITE. YOUR DEMOLITION COMPANY SHOULD BE ABLE ARRANGE THIS FOR YOU.
PART OF DEMOLITION.
NO ALLOWANCE FOR BOTTLES HOUSE TOTAL FOOTPRINT 182.65m²
5
PLEASE NOTE:-
RELEVANT DOCUMENTED REPORT EVIDENCE & PICTURES FROM PARTIES CARRYING OUT THESE
EXISTING HOUSE SHOWN DASHED TO
BE REMOVED BY OWNER AS PART OF
SITE COVERAGE 28.9%
SERVICES WILL BE REQUIRED TO ENSURE THE FOLLOWING ASPECTS HAVE BEEN COMPLETED DEMOLITION.
EFFECTIVELY TO
MEET BOTH OF BRIGHTON HOMES LEGAL & CONTRACT REQUIREMENTS. THIS PLAN ACCEPTED BY:
BERM (0.3m
50 x 25 x 1000 MIN. L SANDBAGS OVERLAP
MEMBRANE TO BE BIDIM U24 ENG TH 15m MIN. HEIGHT)
STAKE OR CONSTRUCTION SITE ONTO KERB
STAR PICKET OR APPROVED EQUIVALENT
0.2m EXISTING PLEASE NOTE: NO VARIATIONS WILL BE
600
ROADWAY
150
ACCEPTED ON THIS PLAN AFTER SIGNING
GEOTEXTILE GAP BETWEEN SANDBAGS THREE LAYERS OF
BURY APPROXIMATELY 150mm
OF MEMBRANE AND TEMPORARILY
FABRIC
NO
FF
ACTS AS SPILLWAY SANDBAGS WITH SIGNATURE:
RU
50-70mm ENDS OVERLAPPED
NATURAL SURFACE BACKFILL TO RESTORE PRIOR RUNOF
F
DOWNHILL OF MEMBRANE NATURAL SURFACE LEVEL GRAVEL
NOT TO BE DISTURBED RUNOFF FROM PAD
DIRECTED TO SEDIMENTATION TRAP SANDBAG KERB INLET DATE:
SILT FENCING DETAIL TEMPORARY CONSTRUCTION EXIT SEDIMENTATION TRAP
© 2022 BRIGHTON HOMES PTY LTD (ABN 59 089 524 050 / ABN 82 003 687 232). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). BRIGHTON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND
UNDERTAKE THAT YOU WILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF BRIGHTON HOMES PTY LTD.
SPECIFICATION: REVISION DRAWN CLIENT: HOUSE DESIGN: HOUSE CODE: DO NOT SCALE DRAWINGS, USE
FIGURED DIMENSIONS ONLY. CHECK
GALLERY MR. IAN MASSEY & MS. SARNA ANNABELLA AURORA 35 H-BBRAUR20DA
Template Version: 21.034
1 CONSOLIDATED TENDER PLANS RLA 2022.08.15 AND VERIFY DIMENSIONS AND
LEVELS PRIOR TO THE
COPYRIGHT: 2 PLAN AMENDMENTS RLA 2022.08.22 ADDRESS: FACADE DESIGN: FACADE CODE: COMMENCEMENT OF ANY WORK. ALL
DISCREPANCIES TO BE REPORTED
© 2022 3 PCV002 ASR 2022.09.06 24 MAHENO COURT, SUNRISE BEACH QLD 4567 CLASSIC F-BBRAUR20CLASA TO THE DRAFTING OFFICE.
502921
LOT / SECTION / SP/RP: COUNCIL: SHEET TITLE: SHEET No.: SCALES:
33 / N/A / CP908656 NOOSA SHIRE COUNCIL SITE PLAN 1:250 2 / 16 1:250
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.