Log in to see the plans as drawn 2. 3. P R O P O S E D D E V E L O P M E N T D R A I N A G E P A T T E R N
2.3.1 Stormwater Concept
Under existing conditions, the stormwater is discharged from the property as overland
surface flows towards Lake Doonella to the south of the sites. It is proposed that this will
remain the lawful point of discharge for the proposed development with the design
required to demonstrate no worsening of the peak discharges for the design storms for the
proposed development compared to the existing state.
Roof run-off for each unit will be collected and flow via downpipes into a 3kL slim-line
rainwater tank. The tanks will be plumbed for internal reuse in toilets and laundry areas, with
1.5kL of the tank allocated for reuse, and the remaining 1.5kL per tank dedicated to
attenuating site run-off to existing conditions. To minimise pollutants entering the tank, first
flush diverters will be installed to divert the initial capture of roof water to irrigation of the
vegetated areas on site.
The driveway run-off will be collected via grated trench drains that will filter through Ocean
Protect Ocean Guard litter basket (or approved equivalent) to provide primary treatment of
gross pollutants and larger particulates from the run-off.
Run-off from the upstream footpath catchments will be intercepted at the driveway access
to the site with a grated trench drain to control its flow through the site within the internal
drainage network.
Run-off from the rainwater tank overflows, driveway and upstream footpath areas will be
discharged overland through turfed buffer zone providing for further treatment and
reduction of flow rates to run-off before it leaves the site.
The roof and allotment drainage system for the proposed site shall be designed to comply
with:
1. Noosa Shire Council Planning Scheme Policy (PSP) - Engineering Design Standards
– Roads, drainage and earthworks;
2. The Queensland Urban Drainage Manual (QUDM); and
3. AS/NZS 3500.3:2015 - Plumbing and Drainage Part 3: Stormwater Drainage.
2.3.2 Stormwater Catchments
A schematic layout plan of the proposed development and its drainage catchments as
described in the previous sections is shown below in Figure 2.3 – Proposed Catchments
Plan.
Page 4 of 14
P +61 7 5211 1003 A 37 Mary St, Noosaville Qld 4566 E [email protected] recorconsulting.com
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.