07/2173 - Operational Works - Prescribed Tidal Works Transport Type 5 - Pontoon [As Published] · 142007.2173
a ETT i Dt Ave 2 i Our Ref 07900-05-244 Contact Paul Calver 29 August 2007 The Manager The Jetty Specialist Pty Ltd 2 Industrial Ave CALOUNDRA QLD 4551 Dear Sir, Structural Design Advice Project: Pontoon, Piles & Catwalk Owner: Body Corp for Hilton Park Address: 82 Hilton Terrace, Noosaville, QLD BY: .--2scnnnnneeeeecces | Cardno Ullman& Nolan Shaping the Future Cardno Uliman & Notan Pty Ltd ABN 36 103 205 170 5 Gardner Close Milton Q 4064 PO Box 388 Toowong Queensland 4066 Australia Telephone: 07 3100 2199 Facsimile: 07 3369 9722 Intemational: +617 3100 2199 Email: [email protected] Web: www.cardno,.com.au Cardno Offices We, Cardno Ullman & Nolan Pty Ltd, advise that the proposal to construct the —_ Brisbane works described above has been checked by us. When the works are constructed Sydney in accordance with the approved drawings and in the location shown, the Canberra Melbourne proposed works are structurally adequate for the anticipated usage in this per, location and should comply with the design and safety provisions of the — Darwin Prescribed Tidal Work Code (Schedule 4A of the Coastal Protection and Management Regulation 2003), based on the design criteria, and assumptions listed below. Basis of Design Advice Caims Townsville Mackay Rockhampton Hervey Bay Sunshine Coast Toowoomba ¢ The works do not impose loads that would significantly affect Gold Coast existing structures. Gosford Baulkham Hills ¢ The works do not adversely affect the stability of the bed and banks 3, .coiton in the near vicinity of the structure. e Structural design criteria: 400mm wind wave 300mm boat wake Wind Classification N3 Maximum Wave Height Papua New Guinea Indonesia Vietnam China Kenya United Arab Emirates Max. Current Scour Debris Load Impact Loads Max Vessel Size berthed Relevant Codes 1.5 m/s parallel to face of pontoon Reasonable scour effects from flood flows and tidal flows have been considered To AS 3962 Minor loads without some damage to structure 2 x 6.0 metres length (wet) & 4.5m beam (wet) AS1170, AS 3962 and AS 3600, except where varied by the Prescribed Tidal Work Code ZAUN\PCProject\2007\Cardno\7900-05'\Sub244\WordiDesign Advice.doc United Kingdom United States 2005s 3 4 we Sey a S: NA . ’ toy Eitalince on Mann esin ato sees | + 1 % The Atocatono Conmuting Enginesrs: CEMTIFIED QUALITY Aaa ASAE WENT SVSTEM a
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2173 - Operational Works - Prescribed Tidal Works Transport Type 5 - Pontoon [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.