Reference Document - EXE25 0032 (As Published)
A B C D E F G H I
7725 7700 7550 7725 6100 6200 6200 5300
RD: EXISTING ROOF DOME
LOWLINE TURBO VENTILATOR
LTV.400 TYPE 1: 1 PER UNIT TRANSLUCENT ROOF SHEETING EXISTING ROOF MOUNTED
1 SHEET PER UNIT IN MIDDLE, SOLAR PANELS
LENGTH AS SHOWN
1
RD RD RD RD RD RD RD
6000
9100
12400
2
RC RC
2° PITCH
2° PITCH
2° PITCH
2° PITCH
2° PITCH
6400
3300
3
RC RC
EXISTING EAVES GUTTER
6000
ROOF SHEETING: .047 ZINCALUME® STEEL
TRIMDEK WITH 50mm LW ANTICON INSULATION
TO UNDERSIDE OF SHEETING ON SAFETY MESH.
NEW ZINCALUME ROOF FLASHINGS TO MATCH
ROOF SHEETING
4
4800 11950 7550 7600 17400 5200
4800
COUNCIL ANNOTATION:
Exemption Certificate EXE25/0032
only relates to the replacement of the
5 existing roof and upgrade of ground
EXISTING EAVES GUTTER floor toilets from code assessment for
building works within the Medium
ZINCALUME CAPPING TO WALL
PARAPET: TYPICAL
Impact Industry Zone.
PROPOSED SCOPE OF WORKS: ROOFING PROPOSED SCOPE OF WORKS: MECHANICAL
1. All roofing works will be carried in accordance with all relevant Australian Standards and the design 1. All mechanical works to be carried out in accordance with Australian Standards and Mechanical NOOSA COUNCIL
drawings. The works include and are limited to the following items, Engineers requirements. The works include and are limited to the following items, REFERENCE DOCUMENT
2. Replace existing roof,gutters and down pipes to be replaced. Roof sheeting to be COLORBOND® Steel 2. Supply and install mechanical ventilation to each WC block.
Trimdek with 50mm LW Anticon insulation to underside of sheeting on safety mesh.
EXE25/0032 25 AUG 2025
A ROOF PLAN: EXISTING & PROPOSED 3. Facia and box gutters supported on proprietary brackets and discharged via PVC downpipes sized in
accordance with the Hydraulic Engineers design.
- Scale 1:150 @ A3
4. Install additional solar panels. Confirm quantity with client
REFER TO DRAWING A040 FOR FINISHES SCHEDULE
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A120
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
ROOF PLAN: EXISTING & PROPOSED Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025