         HANDI-MATE ™ HM6 HINGED DOOR SHED INSTALLATION GUIDE


Fit the Door Shroud into the Wall Channel (Long). Fasten the        Using the Corner Bracket pilot holes as a guide, drill holes in
Door Shroud to the Wall Channel with two 10x16 Hex-Head             all four corners with a 10mm masonry drill bit. Secure all four
Screws (Figure 5.3).                                                bottom Corner Brackets to the concrete base with M8x47
                                                                    Masonry Anchors (Figure 6.1).




                 10x16 Hex-Head Screw                                            Masonry Anchor

                                                                                                     Hold Down Lug
                             Door Shroud




                                              Wall Channel - Long                Hold Down Lug               Hold Down Lug
                                                                                           Corner Bracket




                                                                    FIGURE 6.1


                                                                    Fit a Hold Down Lug at Hold
                                                                                              the middle
                                                                                                  Down Lugof both Long Wall
FIGURE 5.3                                                          Channels. Fasten one 10x16 Hex-Head Screw through each
                                                                    Hold Down Lug into the Wall Channel and Wall Sheet. Fix
                                                                    both Hold Down Lugs to the concrete base with M8x47
                                                                    Masonry Anchors (Figure 6.2).
SHED ANCHORING
Check the walls are square. Check the diagonal
measurements from corner to corner. The diagonal
measurements should be equal for the walls to be square.

Note: Shed anchoring requirements are determined by
the wind zone the Handi-Mate is installed in. Contact a
Stratco store for further information or to determine your
wind zone.
The recommended anchor spacing in Figure 6.0 below,                      Masonry Anchor
where anchor points are no greater than 900mm apart,                                                                 Bottom Channel
will satisfy engineering requirements for N1, N2 and N3                 10x16 Hex-Head
wind zones.                                                             Screw

                                                                                 Hold Down Lug

                                                                    FIGURE 6.2




                     ‘X’ - Anchor Locations




FIGURE 6.0

Log in to download the original (Approved Plan - Landscape Specification prepared by URBIS - OPW24_0110.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.