Original source · versioned page text
2 David Low Way - Town Planning Report - Urban Systems Pty Ltd
Attached to the e-mail Reconfiguration of a Lot (1 lot into 6) - RAL17/0501.
Original PDF page 70, section 1. The text section number identifies this passage in the reader.
Table 18—Specific outcomes and probable solutions for the reconfiguring a lot code
Specific outcome Probable solution Applicant response
b) 1 in 20 (5%) when measured
from the front to the rear of the lot.
O14 For residential development, S14.1 No Solution provided Complies with specific outcome
the subdivision design provides for Each lot is within 20 degrees of
the maximum practicable number the east-west access to facilitate
of lots with house site areas that— solar access.
a) maximise solar access to the
north in winter;
b) minimise solar access to the
east and west in the summer;
c) maximise access to any
prevailing summer breezes; and
d) minimise exposure to prevailing
winter winds.
14.189 Infrastructure
O15 Each lot is capable of being S15.1 All lots are connected to Complies with probable solution.
serviced by appropriate levels of— power supply and Each lot is capable of being fully
a) water supply; telecommunications services; serviced.
b) reticulated sewerage; AND
c) stormwater drainage;
d) power supply; and
e) telecommunications;
O16 The design and provision of S16.1 For lots in urban Complies with probable solution.
public services and utilities, settlements—power supply and Each lot is capable of being fully
including sewerage, water, communications infrastructure are serviced.
electricity, street lighting and provided underground;
telecommunication services— OR
a) meets the needs of users; S16.2 For lots elsewhere—power
b) ensures health, safety and supply and communications
convenience of the community; infrastructure are provided
c) protects the natural underground unless—
environmental values of the site a) located in the Rural Zone or
and surrounds, including visual Rural Settlement Zone and where
amenity and native vegetation; not in a Bushfire Hazard Area as
d) are cost effective over their life defined on Overlay Maps OM1.4-
cycle; OM9.4;
e) minimises adverse impacts to b) new low voltage lines can be
the environment (including the strung from poles carrying existing
amenity of the local area) in the high voltage lines; or
short and long term; and c) no extensions to the existing
f) ensures that the existing systems reticulation network is necessary;
are upgraded or relocated to be or
capable of supporting the proposed d) it is necessary to cross a body
development; of water; AND
S16.3 Street lighting is provided in
accordance with Section 3.19 of
PSP5 Engineering Design
Standards – Roads, Drainage and
Earthworks;
AND
ROL, 2 David Low Way Page 46 August, 2017