Appendix E - Dual Occupancy and Multiple dwelling Code

of 4

Page text shows just the words. Original shows the document exactly as it was published.

Attachment E Dual Occupancy and Multiple Dwelling Code
Development Permit for Material Change of Use of Premises for a Multiple Dwelling of 4 Units and Operational Works
over Lots 3 and 4 on RP72986 located at 30 & 32 James Street Noosaville

                   Column 1                                         Column 2                                           Column 3
           Performance Outcomes                               Acceptable Outcomes                                     Compliance
 1.       is provided to all dwellings and is    each dwelling at the following rate:                provided at ground and on upper levels.
      adequate in size, shape and dimensions      1.       at ground level—a minimum of 25m²
      to suit the needs of the occupants;              directly accessed from living spaces; or
 2.       receives adequate sunlight; and         2.       if above ground level—12m² with a
 3.       is designed and orientated to ensure         minimum width of 2.5 metres accessed
      privacy is maintained between uses.              directly from the living spaces.

                                                 OR

                                                 AO11.2
                                                 Private open space is provided for each             Not applicable
                                                 small dwelling at the following rate:
                                                  1.        at ground level—a minimum of 20m²
                                                        directly accessed from living spaces and
                                                        exclusive of clothes drying area; or
                                                  2.        if above ground level—9m² with a
                                                        minimum width of 2.5 metres accessed
                                                        directly from the living spaces.

                                                 AO11.3
                                                 Private open space contributing to the above        Complies – site is flat
                                                 calculations has a maximum gradient of 10% (1
                                                 in 10) and is clear of any utilities such as gas,
                                                 water tanks and air conditioning units.
PO12                                             AO12.1
Safe vehicular access is provided to and from    Development does not gain direct access from        Complies – James Street is a 50K/hr zonne
the site without adversely impacting on the      any road with a legal speed limit of 80
safety of the road network.                      kilometres per hour or above.

                                                 AO12.2                                              Not applicable – James Street is a local road.
                                                 Where located on any road of a higher order
                                                 than local road or where accommodating three
                                                 or more households, vehicle manoeuvring
                                                 areas are provided on site such that vehicles
                                                 enter and leave the site in a forward gear.
PO13                                             AO13
Sufficient on-site car parking is provided to    Car parking is provided in accordance with          Complies – 8 covered spaces provided with
accommodate the number and type of vehicles      Table 9.4.1.4 in the Driveways and Parking          one visitor space and one uncovered space at
likely to be generated by the residential use    Code                                                the rear of the site.
without impacting on the safety or amenity of
the adjoining streets.                            i)  one covered space up to two bedrooms
                                                      and two covered spaces for three or more
                                                      bedrooms; and
                                                  ii)    one visitor space per four dwellings

PO14
Underground car parking areas are designed to    No acceptable outcome provided                      Not applicable.
drain and function safely during a flood event
and power failure.




                                                        Page 4
Log in to download the original file

Appendix E - Dual Occupancy and Multiple dwelling Code.pdf · 273 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.