C6361-22-ENG - Feb 2023 - V1

Attached to the e-mail RAL21/0022 - 7 Triller Court_ Pomona - Response to Further Advice Matters & Change to app (1 Lot into 4).

of 48

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file (10.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.

Original PDF page 41, section 1. The text section number identifies this passage in the reader.

LEGEND
 For more info contact a Certified Locating Organisation or Telstra Plan Services 1800 653 935


                              Exchange
                              (Major Cable Present)
                                                                                                                      6             Cable Jointing Pit
                                                                                                                                    (number indicating Pit Type)

                              Footway Access Chamber                                                                                Elevated Joint
                              (can vary from 1‐lid to 12‐lid)
                                                                                                                      EJ            (above ground joint on buried cable)

          or                  Pillar / Cabinet                                                                                      Telstra Plant in shared Utility trench
                              (above ground / free standing)
                                                                                                                                    Aerial Cable
                              Above ground complex equipment housing (eg RIM)
                              Please Note: This equipment is powered by 240V Electricity                                            Aerial Cable
                                                                                                                                    (attached to joint Use Pole eg. Power)
           OC                 Other Carrier Telecommunications Cable/Asset
                                                                                                                                    Direct Buried Cable
          Dist                Distribution cables in Main Cable ducts
          MC                  Main Cable ducts on a Distribution plan                                                 M             Marker Post Installed
                              Blocked or damaged duct.

                                                                                                               T or TR              Buried Transponder

                              Roadside / Front Boundary
                              2 pair lead‐in to property from pit in street 1
                                                                                                                    MT              Marker Post, Transponder

                              pair working (pair ID 059)
                              1 pair dead (i.e. spare, not connected)
                                                                                                                   SMOF             Optical Fibre cable direct buried

                              Side / Rear Property Boundary
                              Property Number                                                                Some examples of conduit type and size:
                              Single to multiple round conduit
                              Configurations 1,2,4,9 respectively                                           A ‐ Asbestos cement, P ‐ PVC / Plastic, C ‐ Concrete,
                              (attached text denotes conduit type and size)                                 GI ‐ Galanised iron, E ‐ Earthenware
                                                                                                            Conduit sizes nominally range from 20mm to 100mm
                              Multiple square conduit                                                       P50 50mm PVC conduit
                                                                                                            P100 100mm PVC conduit
                              Configurations 2, 4, 6 respectively
                                                                                                            A100 100mm asbestos cement conduit
                              (attached text denotes conduit type and size)

Some Examples of how to read Telstra Plans
                                            ‐50‐                                                      One 50mm PVC conduit (P50) containing a 50‐pair and a 10‐pair
                                             10                                                       cable between two 6‐pits. approximately 20.0m apart, with a direct
                                                                                                      buried 30‐pair cable along the same route
                        P50                  30                         20.0

                                                                AB
                                                                           AA ‐ (cable information)      Two separate conduit runs between two footway access
                                                                AA BA      AB ‐ (cable information)      chambers (manholes) approximately 245m apart A nest of four
                                                                           BA ‐ (cable information)      100mm PVC conduits (P100) containing assorted cables in three
                 C100                                       P100
                                                                                                         ducts (one being empty) and one empty 100mm concrete duct
                                                                                                         (C100) along

                                                                  245.0


 WARNING: Telstra plans and location information conform to Quality Level ’D' of the Australian Standard AS 5488 ‐
 Classification of Subsurface Utility Information. As such, Telstra supplied location information is indicative only.
 Spatial accuracy is not applicable to Quality Level D. Refer to AS 5488 for further details. Telstra does not warrant or
 hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans. FURTHER
 ON SITE INVESTIGATION IS REQUIRED TO VALIDATE THE EXACT LOCATION OF TELSTRA PLANT PRIOR TO
 COMMENCING CONSTRUCTION WORK. A plant location service is an essential part of the process to validate the
 exact location of Telstra assets and to ensure the assets are protected during construction works. The exact
 position of Telstra assets can only be validated by physically exposing them. Telstra will seek compensation for
 damages caused to its property and losses caused to Telstra and its customers.


Telstra Map Legend v3_5a                                                                                                        TELSTRA CORPORATION ACN 051 775 556
Log in to download the original file

C6361-22-ENG - Feb 2023 - V1.pdf · 10.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.