Noosa Plan 2020: Amendment 3 test
Part 9 Development codes \ 9.3 Use Codes \ 9.3.4 Special Residential Code




 PO21                                                         AO21.1                                                      Complies.
 Safe vehicular access is provided to and from the site       The residential use does not gain direct access from        AO21.1 - The proposal retains the existing lawful
 without adversely impacting on the safety of the road        any part of the major road network which has a legal        access from Eumundi Noosa Road within the
 network.                                                     speed limit of 90 kilometres per hour or above.             established urban area. The access is not from a
                                                              AO21.2                                                      part of the major road network with a legal speed
                                                              Vehicle manoeuvring areas are provided on site such         limit of 90 km/h or above.
                                                              that vehicles enter and leave the site in a forward gear.   AO21.2 - Existing on-site parking and manoeuvring
                                                                                                                          areas are retained and provide sufficient area for
                                                                                                                          vehicles to manoeuvre so that they can enter and
                                                                                                                          leave the site in a forward gear. No new crossover or
                                                                                                                          intensification of the access arrangement is
                                                                                                                          proposed.
 PO22                                                  AO22                                                               Complies.
 Site design and layout ensures emergency services     Efficient and safe access and egress for emergency                 AO22 - The proposal retains the existing vehicular
 personnel and vehicles have access to the premises at vehicles is provided.                                              access from Eumundi Noosa Road and the existing
 all time.                                                                                                                internal access and parking area. The development
                                                                                                                          does not introduce new structures that would
                                                                                                                          obstruct emergency access and the existing
                                                                                                                          arrangement provides direct access to the premises
                                                                                                                          from the public road network.
 PO23                                                  No acceptable outcome provided                                     Complies with PO23.
 Sufficient on-site car parking is provided to                                                                            No acceptable outcome is provided. Six existing on-
 accommodate the number and type of vehicles likely to                                                                    site car parking spaces will be retained for the
 be generated by the residential use having regard to                                                                     proposed five-bedroom Rooming Accommodation
 the number of dwellings, residents, visitors or staff                                                                    use. The parking supply is considered sufficient for
 (including changeover of shift workers).                                                                                 the anticipated residential scale of the use and the
 Editor’s Note— detailed parking requirements including the                                                               proposal will generate fewer and less concentrated
 rate of vehicle parking are addressed in the Driveway and                                                                vehicle movements than the former child care
 Parking Code.                                                                                                            centre, particularly during peak drop-off and pick-up
                                                                                                                          periods.




Print Date: 17/06/2026                                                                                                                                                   Page 10

Log in to download the original (Appendix B - Code Assessment.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.